Agnel sur SeineElectric scissor type lifting platformHow to improve the accuracy to facilitate the solution of manufacturing difficulties

announcer:hp935HP175192871 release time:2024-04-21 10:22:17

Agnel sur SeineElectric tricycle hydraulic elevator,

Use floor doors and cage door devices on construction sites where conditions permit.

According to the needs of different performance genres, the form of the stage can be changed. For example, using an orchestra pit lift can combine a framed stage with a large lip or even an extended stage. In an experimental theater, an extended stage, an island stage an intermediate stage, a T-shaped stage, but should not trigger the up travel (limit) switch as high

When a rigid 5000mm2 square or circular flat surface is applied with a normal force of 600N to either side of the door, the door may not meet the above requirements, but safety should be maintained.

.When applying a normal force of 300N to any position on either side of the door using a rigid 5000mm2 square or circular flat surface in the locked position of the landing door, the door should be able to withstand and have no deformation; - Deformation not exceeding 30mm; After the test, it worked normally.

When the landing door is closed, the full width of the lifting passage opening should be covered.

Steel wire ropes, pulleys, and counterweight steel wire ropes shall comply with the following regulations: the characteristics of steel wire ropes shall comply with the requirements of General Purpose Steel Wire Ropes GB/T20118; Maintenance, wear, deformation, and corrosion of steel wire ropes


Agnel sur SeineElectric scissor type lifting platformHow to improve the accuracy to facilitate the solution of manufacturing difficulties



The net height of the landing door opening should not be less than 8m,Agnel sur Seine6-meter electric elevator, and the difference between the net width and the outlet width of the cage door should not exceed 120mm. When the floor door is closed, except for the gap between the lower part of the door that should not exceed 35mm, the size of any through-hole and opening related to the distance between any door and adjacent moving parts, as well as the gap around the door or between parts, should comply with the provisions of Table 4 of 'Mechanical Safety - Safety Distance to Prevent Upper and Lower Limbs from Touching Dangerous Areas' GB23821-2009.

The stopper bearing of the mechanism is kept intact.

Construction electric elevators should be equipped with cable guide frames and comply with regulatory requirements.

quality index.Flat screw mechanical electric lifting mechanism: The lifting platform of this structure has the advantages of small civil engineering coordination, shallow foundation pit required, large stroke, accurate positioning low noise, and low cost. Adopting a horizontal screw drive and a scissor fork structure to achieve the lifting motion of the table, it can be stopped arbitrarily within the range of travel.

Once again, weekly inspections should be conducted to check whether the connecting screws at various parts of the lifting platform are tightened, whether the sealing rings are damaged or ineffective whether there is a lack of hydraulic oil,Agnel sur SeineElectric elevators for construction sites, and whether the oil cylinder is leaking. It is necessary to clean the lifting frame, scissors, wiring, and oil cylinder once a week to avoid dust and debris affecting normal operation.

The counterweight guide rail should meet the specification requirements.


Agnel sur SeineElectric scissor type lifting platformHow to improve the accuracy to facilitate the solution of manufacturing difficulties



During loading and unloading, the horizontal distance between the edge of the cage door and the edge of the landing station should not exceed 50mm.

Inspection environment.High lifting height, using side mounted oil cylinders, stable operation, noise free, easy maintenance, and longer service life.

The stopper bearing of the mechanism is kept intact.

The landing door should meet the requirements of the specifications and achieve standardization.

Agnel sur Seine.Setting requirements: The main connection methods between the wall bracket and the building include: connecting the wall bracket with the embedded parts on the wall; Fix with wall bolts; Embedded bolts; Welding with steel structures.

Every theater is a public place with a large number of people, and safety considerations should be taken into account in stage design. According to relevant national regulations, in order to prevent accidents caused by the crushing of electric elevators or improper control by drivers. Electric elevators should be equipped with the following necessary safety devices to ensure that the car of the electric elevator stops rising or falling in a timely manner.

Installation and dismantling personnel and drivers should hold certificates to work.