Koboshburg2 meter electric elevatorThe difference when used in low temperature pipelines

announcer:hp935HP175192871 release time:2024-04-16 13:57:58

The safety bulletin board for construction electric elevators should be hung at the protective shed of the electric elevator with a size of 8 meters by 2 meters.

Then, the lifting platform platform platform that carries the load needs to be balanced, and no deviation of one side is allowed. The lifting of goods does not allow people to stand on both sides of the platform, and the lifting of goods should try to maintain a stable and uniform speed.

Koboshburg.Pole

When the door is closed,KoboshburgElectric three wheel elevator, except for the gap between the lower part of the door that should not exceed 35mm, any through-hole and opening size related to the distance between any door and adjacent moving parts, as well as the gap around the door or the gap between parts, should comply with the provisions of Table 4 of GB 23821-2009.

.The L distance depends on the selected wall mount model.

Human improper operation is the main factor causing malfunctions in scissor type electric elevators. When stacking goods, electric elevators should stack the goods neatly, which is better than stacking them in the center of the cargo stacking area of the cargo elevator to avoid imbalance between the two ends of the stacking area. Eventually, during the operation of the electric elevator,KoboshburgFully automatic elevator electric, it may cause the electric elevator to lose balance. After the goods are stacked completely, ropes should be used to lock the goods so that they are not afraid of the goods during the lifting process; Careless; Scattered down

The spacing between wall brackets and the height of guide rails above the high attachment point should comply with the requirements of the user manual.


Koboshburg2 meter electric elevatorThe difference when used in low temperature pipelines



When the door is closed, except for the gap between the lower part of the door that should not exceed 35mm, any through-hole and opening size related to the distance between any door and adjacent moving parts, should comply with the provisions of Table 4 of GB 23821-2009.

Normal operation starts. Click on this free download of construction technical information. Safety limit devices should be installed on electric elevators for construction, with upper and lower limit switches that are sensitive and reliable.

When the wall bracket adopts non matching standard products, design calculations should be carried out.

Product survey.During the use period, the user unit should organize professional technical personnel to inspect the construction electric elevator monthly according to the standard requirements, the door may not meet the above requirements,KoboshburgElectric mobile elevator, but safety should be maintained.

The device should be used within the valid calibration period and operate effectively and reliably. The anti fall safety device should have a valid inspection certificate (or inspection report), and the validity period should not exceed 1 year. Anti fall safety devices have been manufactured for five years

Setting requirements: When the distance between the outer edge of the construction electric elevator and the external overhead power line cannot meet the requirements of a small safety distance, the protective measures taken should comply with the specification requirements.

Koboshburg.Emergency manual valve: In case of power failure, it can cause the car to descend to the nearest floor position and open the door

The safety bulletin board for construction electric elevators should be hung at the protective shed of the electric elevator, with a size of 8 meters by 2 meters.

Drivers of construction electric elevators should hold special construction operations and are not allowed to operate without a certificate.