Sivetohelovi ćElectric cargo elevatorThere are many things to pay attention to in the selection of materials

announcer:hp935HP175192871 release time:2024-03-22 09:03:15

The foundation base or embedded parts should be fully embedded in the concrete foundation plate.

Monthly maintenance and inspection of hydraulic lifting platform rollers, oil cylinder pin shafts and bearings, boom hinge shafts and bearings for wear. Add some oil to each part to extend the service life of the lifting platform bearings. The quality and level of hydraulic oil. The lifting platform should be raised throughout the entire process,Sivetohelovi ćAutomatic elevator electric small, and at this position, the hydraulic ground should be 40-50 millimeters higher than the bottom of the box. If the hydraulic oil becomes dark, sticky, or has foreign objects such as gravel, it should be replaced in a timely manner (32 # hydraulic oil). Annual maintenance and inspection of all hydraulic pipelines and joints of the lifting platform. The pipeline must not be damaged, and the joints must not be loose. All joints must be tightened. Remove and disassemble the lowering valve of the lifting platform blow out the plunger with compressed air, then install it and reinstall it. Drain and discard the hydraulic oil, tighten the joint, remove the oil filter,Sivetohelovi ćElectric small hydraulic elevator, and then return it to the oil tank and connect the pipeline.

Sivetohelovi ć.Before installing the construction electric elevator, the foundation should be inspected and approved before installation.

When the landing door is closed, the full width of the lifting passage opening should be covered.

.Small safe operation distance: Circuit voltage (kV) of external power lines<11~1035~110220330~550 Small safe operation distance (m) 4681015 Setting requirements: A small safe distance should be maintained between the outer edge of the construction electric elevator and the edge of the external overhead power line.

Operating cost advantage and low failure rate: Due to the use of advanced hydraulic systems and good methods, the operating failure rate can be reduced to a low level.

Setting requirements: When the distance between the outer edge of the construction electric elevator and the external overhead power line cannot meet the requirements of a small safety distance, the protective measures taken should comply with the specification requirements.


Sivetohelovi ćElectric cargo elevatorThere are many things to pay attention to in the selection of materials



The angle between the wall bracket and the horizontal plane should comply with the requirements of the user manual.

Is the water cooling and air cooling of the hydraulic station the same?

The bearing capacity of the ground under the concrete foundation plate should be greater than 0.15Mpa.

How much is it.The safety distance between the outer edge of the upper part of the landing door and the moving parts of the electric elevator during normal operation should not be less than 0.75m; If the rated speed is not greater than 0.7m/s, the safety distance can be 0.40m.

Setting requirements: The verticality deviation of the installation of the guide rail frame of the construction electric elevator should comply with the requirements of the user manual and specifications,Sivetohelovi ćElectric one ton elevator, as specified in the above table.

The safety notice board for construction electric elevators should be prominently placed on the hanging cage for the rated load capacity and rated number of passengers of the construction electric elevator. It is strictly prohibited to use construction electric elevators beyond the rated load capacity or rated number of passengers.


Sivetohelovi ćElectric cargo elevatorThere are many things to pay attention to in the selection of materials



The pump body adopts an integrated pump station all equipped with imported high-quality pump stations, which can also be selected according to customer requirements to meet customer ideal requirements.

Quality documents.When a rigid 5000mm2 square or circular flat surface is applied with a normal force of 600N to either side of the door, the door may not meet the above requirements, but safety should be maintained.

Lower limit switch: In normal working state, before the suspension cage touches the buffer, the lower limit switch first acts.

Use floor doors and cage door devices on construction sites where conditions permit.

Sivetohelovi ć.Before installation, the installation unit should confirm that the foundation, foundation bearing capacity, embedded parts, and foundation drainage measures of the installed construction electric elevator and auxiliary heavy equipment comply with the requirements of the special construction plan for the installation and dismantling of the construction electric elevator based on the construction electric elevator foundation acceptance form, concealed engineering acceptance form, and concrete strength report.

The quality of the standard section should comply with the product manual and specification requirements.

The bearing capacity of the building structure at the attachment point of the wall bracket should meet the requirements specified in the user manual for construction electric elevators.