ShuangqiaoElectric curved arm elevatorYou are welcome to contact

announcer:hp935HP175192871 release time:2024-02-26 12:17:22

The use of standard section connecting bolts should comply with the user manual and specification requirements.

The safety distance between the outer edge of the upper part of the landing door and the moving parts of the electric elevator during normal operation should not be less than 0.75m; If the rated speed is not greater than 0.7m/s, the safety distance can be 0.40m.

Shuangqiao.The impact load can cause early wear, fracture,ShuangqiaoExternal wall electric elevator, and fragmentation of mechanical structural components, as well as generate impact pressure in the hydraulic system, which in turn can damage hydraulic components, oil seals, and high-pressure oil

The connection method and angle between the wall bracket and the building structure should comply with the requirements of the user manual.

.Operating cost advantage and low failure rate: Due to the use of advanced hydraulic systems and good methods the operating failure rate can be reduced to a low level.

In addition to ground protective fences,ShuangqiaoHand propelled electric elevator, low level doors can be used. Low level doors should meet the following requirements: the height of the door should be between 1m and 2m. And there should be at least protective railings, a half height middle crossbar, and a toe board at least 150mm above the ground.

In order to meet the needs of contemporary audiences and achieve perfect effects, in addition to lighting and sound, there are suspension rods, suspension points,ShuangqiaoSmall electric elevator platform, lighting bridges, lighting suspension cages, and fire curtains. Under the stage, there are lifting platforms, car platforms, turntables, and lifting orchestras. Some lifting platforms are equipped with turntables, dance theaters, drama theaters and many internationally renowned music halls. It has the functions of quickly changing scenery, meeting the needs of stage craft layout, meeting the needs of stage design and choreographers, creating special atmosphere and effects, and changing the stage form according to the needs of the performance.


ShuangqiaoElectric curved arm elevatorYou are welcome to contact



When the wall bracket adopts non matching standard products design calculations should be carried out.

The usual operation of landing and docking.

The connection method and angle between the wall bracket and the building structure should comply with the requirements of the user manual.

manufacturer.High lifting height, using side mounted oil cylinders, stable operation, noise free, easy maintenance, and longer service life.

Setting requirements: When the distance between the outer edge of the construction electric elevator and the external overhead power line cannot meet the requirements of a small safety distance, the protective measures taken should comply with the specification requirements.

Setting requirements: The foundation and foundation of the construction electric elevator should meet the requirements of the user manual. Before installing the construction electric elevator, the foundation should be inspected and accepted according to the requirements of the specifications. Only after passing the inspection can the installation be carried out.


ShuangqiaoElectric curved arm elevatorYou are welcome to contact



The advantages and disadvantages of several commonly used electric lifting mechanisms are as follows: hydraulic electric lifting mechanisms: using hydraulic technology, smooth lifting and low noise.

resources.Setting requirements: Drainage measures should be set up for the foundation of construction electric elevators to ensure smooth drainage.

Limit switches should be triggered directly by the movement of the suspension cage or its related components.

Construction electric elevators should be equipped with cable guide frames and comply with regulatory requirements.

Shuangqiao.Secondly, the lifting platform is driven by electrical energy and lifted by the hydraulic system. During operation, it is necessary to avoid irregular operations. To ensure the normal and orderly operation of the lifting platform and achieve the ideal unloading level, timely inspection of various functions is essential.

The scissor type electric elevator is a widely used high-altitude operation special equipment. Its scissor mechanical structure ensures high stability of the lifting platform, wide working platform, making the high-altitude operation range wider and suitable for multiple people to work simultaneously. It makes high-altitude operation more efficient and safer

When the door is closed, except for the gap between the lower part of the door that should not exceed 35mm, any through-hole and opening size related to the distance between any door and adjacent moving parts, as well as the gap around the door or the gap between parts, should comply with the provisions of Table 4 of GB 23821-2009.