ShanhaiguanElectric light liftExports continue to increase

announcer:hp935HP175192871 release time:2024-02-25 10:03:45

The motor of the hydraulic guide rail lifting platform is set around the wellbore, occupying a relatively small area,ShanhaiguanElectric cargo elevator, improving the utilization rate of the wellbore area.

Protective measures should comply with regulatory requirements.

Shanhaiguan.Try to use this equipment in areas with wind force less than level five, and avoid using it when the wind force is too strong to avoid accidents.

Before installation, the installation unit should confirm that the foundation, foundation bearing capacity embedded parts, and foundation drainage measures of the installed construction electric elevator and auxiliary heavy equipment comply with the requirements of the special construction plan for the installation and dismantling of the construction electric elevator based on the construction electric elevator foundation acceptance form, and concrete strength report.

.The spacing between wall brackets and the height of guide rails above the high attachment point should comply with the requirements of the user manual.

Setting requirements: The quality of the standard section should meet the requirements of the product manual. Before installing the construction electric elevator,ShanhaiguanElevator manufacturer's electric elevator, all components should be inspected, and standard sections and other components with severe wear and deformation should be replaced.

The landing door should be in a normally closed state. Without the permission of the construction electric elevator driver, the landing door shall not be opened.


ShanhaiguanElectric light liftExports continue to increase



The verticality of the guide rail frame should meet the requirements of the specifications.

Pole

In addition to ground protective fences, low level doors can be used. Low level doors should meet the following requirements: the height of the door should be between 1m and 2m. And there should be at least protective railings, a half height middle crossbar, and a toe board at least 150mm above the ground.

original.Operating cost advantage and low failure rate: Due to the use of advanced hydraulic systems and good methods, the operating failure rate can be reduced to a low level.

When the door is closed, except for the gap between the lower part of the door that should not exceed 35mm, as well as the gap around the door or the gap between parts, should comply with the provisions of Table 4 of GB 23821-2009.

Every theater is a public place with a large number of people, and safety considerations should be taken into account in stage design. According to relevant national regulations, in order to prevent accidents caused by the crushing of electric elevators or improper control by drivers. Electric elevators should be equipped with the following necessary safety devices to ensure that the car of the electric elevator stops rising or falling in a timely manner.


ShanhaiguanElectric light liftExports continue to increase



For customers to use and operate the lifting platform for a long time,Shanhaiguan2 meter electric lifting platform, the editor briefly introduces how to maintain and repair the lifting platform: First of all, normal maintenance is mainly focused on prevention, especially if any damage or malfunction is detected and corrected or repaired in a timely manner. Careful inspection and maintenance at this time can save costs and avoid larger problems resulting in costly repairs.

Focus on Development.When applying a normal force of 300N to any position on either side of the door using a rigid 5000mm2 square or circular flat surface in the locked position of the landing door, the door should be able to withstand and have no deformation; - Deformation not exceeding 30mm; After the test, it worked normally.

Before each shift of work, the safety devices of the construction electric elevator should be inspected to ensure sensitivity and reliability.

Drainage measures need to be considered around the foundation. (Drain the accumulated water on the foundation).

Shanhaiguan.Setting requirements: Each landing entrance should be equipped with a landing door, which should cover the opening with its full width, and should not open towards the lifting passage.

Safety performance: Electric elevators not only have the safety device of traditional traction elevators, but also have an overflow valve to prevent excessive system pressure during upward movement

To ensure safe and reliable braking of the lifting platform and prevent accidents, a hydraulic control one-way valve, also known as a hydraulic lock, is added to ensure safe self-locking in the event of an accidental rupture of the hydraulic pipeline. An overload sound control alarm has been installed to distinguish between overload or equipment failure. Electrical system explosion-proof button SB1&flash; The rotation of the SB6 motor and the commutation of the explosion-proof electromagnetic directional valve are used to maintain load increase or decrease, and; Program adjustment time delay to avoid frequent movement of electric elevators that may affect their service life.