PSV EindhovenAluminum alloy hydraulic elevatorWhat to pay attention to when choosing

announcer:hp750HP120486450 release time:2024-04-12 13:02:28

Hydraulic aluminum alloy elevators operate up and down and can provide us with a safe and stable platform. We can provide security for our safety when working at heights.

Problem: The power indicator light of the aluminum alloy elevator is not on, which have the advantages of beautiful appearance, small size, light weight, balanced lifting, safety and reliability. They are widely used in factories, hotels, restaurants, stations, airports, theaters, exhibition halls and other places. They are a good safety partner for maintenance equipment, paint installation, lamp replacement, electrical appliances, cleaning and maintenance, and other purposes.

Regularly check the connection of each part and tighten it if there is any looseness. The tightness of the body connecting bolts should be checked when the body is under pressure (the rotating arm can be used to cause compression), and all connecting shafts must have split pins and be sufficient. Professional items

.Hydraulic lifting platform products are divided into curved arm hydraulic aluminum alloy elevators scissor fork hydraulic aluminum alloy elevators, mast hydraulic aluminum alloy elevators, and straight arm hydraulic aluminum alloy elevators according to their working modes. Hydraulic aluminum alloy elevator is a replacement product of folding arm aluminum alloy elevator (lifting platform) and scissor fork aluminum alloy elevator (lifting platform). It can be widely used for the decoration and decoration of stations,PSV EindhovenAluminum alloy elevator, docks, airports, hotels, posts and telecommunications, municipal gardens, grain depots, cleaning companies, or the installation and maintenance of power systems. This aluminum alloy elevator has the advantages of light weight, self-propelled walking, self supporting legs, simple operation, large working area, and especially the ability to cross obstacles for high-altitude operations.

Therefore, using a stable voltage for aluminum alloy elevators is crucial for safe operation. Aluminum alloy elevators have high stability, a wide working platform, and a high load-bearing capacity making high-altitude operations more efficient and safe. To avoid the harm of voltage instability, please ensure voltage stability.

Therefore, using a stable voltage for aluminum alloy elevators is crucial for safe operation. Aluminum alloy elevators have high stability, and a high load-bearing capacity, making high-altitude operations more efficient and safe. To avoid the harm of voltage instability, please ensure voltage stability.


PSV EindhovenAluminum alloy hydraulic elevatorWhat to pay attention to when choosing



Three masts aluminum alloy elevator: The main structure is made of high-quality high-strength aluminum profiles, greatly reducing the overall height during transportation, and making loading and unloading convenient. This machine has strong load-bearing capacity and is suitable for 2-3 people to climb heights simultaneously.

The hydraulic system is equipped with an emergency descent function to prevent power outages and unexpected situations, and the emergency operation is simple.

Good driving performance reduces noise, increases the clearance inside the platform, and also makes the transmission smoother and the mechanism vibrates less.

Energy costs.. Before the maintenance of the hydraulic aluminum alloy elevator starts, the tools used must be counted. After the maintenance is completed, the tools should be classified and organized, and counted to prevent the tools used for maintenance from being left inside the equipment, especially in the distribution box. When repairing the hydraulic system of the aluminum alloy elevator, it is necessary to keep the maintenance site clean and dust-free. When repairing and fastening screws for aluminum alloy elevators it is necessary to use the correct diagonal first. When tightening screws, use a torque wrench to prevent excessive damage to the screws. After the maintenance is completed and before the power on test, inspecting and repairing the equipment and the maintenance site, the power transmission test can only be carried out. After the maintenance of the aluminum alloy elevator is completed, the equipment maintenance record must be filled out. The maintenance record should include the equipment maintenance date, the personnel participating in the maintenance, the maintenance items, the brand, model and specification of the replaced parts, the effectiveness of the maintenance, and whether the equipment still has problems after the maintenance is completed.

The main components of the Hunter hydraulic fixed elevator are: 1. The shaft part is a closed or mesh frame enclosed by buildings or lightweight steel structures, with steel guide rails installed on both sides of the interior. 2. The driving part is equipped with a hydraulic drive motor, oil pump, and safety valve, A small oil tank for hydraulic components such as speed control valves and directional valves: 3. The oil cylinder part: It is composed of one or more oil cylinders of the lifting oil cylinder straight top platform or lifting shear fork frame: 4. The door system part: It is a closed or mesh platform door or landing door system composed of steel structure, with manual and automatic doors. Generally, open platforms do not have doors. 5. The electrical part: It includes power, signal, Composition of safety and lighting devices: 6 Platform parts: It is a steel structure platform that carries heavy objects, which can be closed (i.e. cabin type) or open, with guide rollers or guide shoes installed on both sides. The bottom of the platform can be connected to a lifting oil cylinder or a lifting shear fork shaped steel frame. When we use aluminum alloy elevators, we need to regularly inspect, maintain, and maintain them, which can not only extend the service life of the aluminum alloy elevator, Can make it work with greater power! For example, the transmission part should have sufficient oil, and vulnerable parts must be regularly inspected, repaired, or replaced. Mechanical bolts, especially parts that frequently vibrate, such as slewing bearings and lifting arm connecting bolts, should be checked for looseness. If there is looseness, it must be tightened or replaced immediately. Next, let's take a look at the regulations for the maintenance time of aluminum alloy elevators: daily maintenance (carried out per shift).

After working for 10000 hours, the mechanical and electrical systems of the elevator will be overhauled.


PSV EindhovenAluminum alloy hydraulic elevatorWhat to pay attention to when choosing



Test run or use completed. The aluminum alloy elevator and site must be cleaned. When closing the aluminum alloy elevator cover or other assembly cover. Items such as tools, rags, and removed parts should be checked for forgetting. After confirming that there are no errors. Only then can it be closed.

Price.Firstly, unstable voltage can easily burn out various electrical components inside the operation box, making the equipment unable to receive signals.

In progress, welcome to consult

Firstly, the maintenance process should be carried out on the premise of ensuring the safety of staff. Before repairing the aluminum alloy elevator,PSV EindhovenCar mounted aluminum alloy elevator, the power must be disconnected, and the power must be verified and hung up; No power transmission, people working&# quo; Identification plate for. During the maintenance process,PSV EindhovenDouble masted aluminum alloy elevator, it is not allowed to disconnect the grounding wire of the aluminum alloy elevator. If it is necessary for maintenance work, after the maintenance is completed, the grounding wire must be connected before the power test can be conducted. When replacing spare parts for aluminum alloy elevators, it is necessary to ensure that the spare parts are intact and of the same model. Items such as valves and seals should be placed in dry and dust-free packaging. When hydraulic aluminum alloy elevator maintenance requires entering the platform for internal work, after the aluminum alloy elevator is lifted, the working surface of the aluminum alloy elevator must be fixed or supported firmly with a crane or other equipment,

PSV Eindhoven.Test run or use completed. The aluminum alloy elevator and site must be cleaned. When closing the aluminum alloy elevator cover or other assembly cover. Items such as tools rags, and removed parts should be checked for forgetting. After confirming that there are no errors. Only then can it be closed.

When repairing an aluminum alloy elevator, in order to protect the safety of workers and ensure the repair effect, there are many precautions to pay attention to during the maintenance process. We have summarized the relevant matters for your reference only.

Attention must be paid to the rotating parts of the aluminum alloy elevator. When the engine is running. Hands and tools must be kept away from rotating fan belts and fans. During the test drive, it is necessary to be in a spacious area and ensure that the aluminum alloy elevator can safely stop and turn effectively.