Nuremberg Large hydraulic lifting platformMain economic and technical indicators are stable and improving

announcer:hp530HP141750488 release time:2024-01-04 11:37:39

Lines of various safety equipment

Protective device: In case of power or oil circuit failure, there should be a safety rope to prevent the workbench from falling out of control. (Allow controlled descent)

Nuremberg .Hydraulic elevators have two working periods and two end dwell times within a working cycle. Working hours refer to the period of lifting and falling objects. The suspension period refers to the period during which the machine temporarily stops working at the required height of rest. Therefore, each working period is divided into three different stages: starting, constant speed lifting, and braking.

Motor not running: Check all components of the motor for damage and check if there are any problems with the circuit and wiring.

.Regularly check the operation of each mechanism for normal operation and noise. If any faults are found, the hydraulic cargo elevator wholesale should be promptly eliminated. Otherwise, it will affect the use of the guide rail hydraulic lifting platform. When refueling, the hydraulic oil should be filtered and filled, and the refueling tools should be reliable and clean. The hydraulic cargo elevator manufacturer should not remove the filter at the fuel tank filler to improve the refueling speed. Refueling personnel should use clean gloves and work clothes to prevent solid and fiber impurities from falling into the oil.

Vehicle mounted lifting platform is widely used for high-altitude operations in hotels, buildings, airports, stations, sports venues, workshops, warehouses, advertising, etc.

When encountering signs of overheating in the electric motor, it is necessary to park the car in a timely manner, clean the problem, and continue running. The motor bearings should be smooth and outstanding.


Nuremberg Large hydraulic lifting platformMain economic and technical indicators are stable and improving



The elevator is evenly distributed at any position on the guide rail at 150% of the maximum load capacity, and should be stable at the maximum lifting height.

The safety belt should be inspected before use and a static load test should be conducted regularly (every 6 months). The load for the boarding bridge test is 225 kilograms, and the test time is 5 minutes. After the test, check for deformation, cracks, etc., and keep test records. Unqualified seat belts should be promptly dealt with.

The noise and oil level of the elevator oil cylinder are too low. From the air at the connection of the oil filter or joint to the oil, the coupling inside the oil cylinder is loose. The internal fault of the oil cylinder is that the installation of the oil cylinder motor is not concentric. From the motor, the air and oil at the moving shaft are blocked. The oil return pipe of the oil filter is loose, and the air or oil pipe is on the oil surface, Mixing air into the oil to eliminate: The concentricity should be adjusted to within 0.1MM. The coupling should be repaired or the oil pump should be replaced to increase the oil volume above 400mm in the oil filter and joint positions. The rotating shaft sealing ring should be replaced to clean the oil filter screen, filter the oil, lock the return oil pipeline, and extend the return oil pipeline below the oil level. If there is air mixed in the oil or the air in the hydraulic cylinder is not completely discharged it will cause cavitation under high pressure and cause significant noise. At this point,Nuremberg Self propelled hydraulic lifting platform, it is necessary to exhaust the air in a timely manner.

investment.The speed circuit is the circuit that switches the motion speed and speed of the actuator in the hydraulic system of the guide rail hydraulic lifting platform. Mainly including valves, pumps, and actuators. The commonly used speed circuits include speed circuits high-speed circuits, even if the butter is polished to increase its properties.

The manufacturer of hydraulic cargo elevators reminds the use of guide rail hydraulic lifting cargo elevators. Guide rail hydraulic lifting cargo elevators: Do not stand within the specified range, prohibit any idle personnel from entering the work area, ensure that the work area is free of clothing and maintain a clean and tidy workplace.


Nuremberg Large hydraulic lifting platformMain economic and technical indicators are stable and improving



Regularly check the operation of each mechanism for normal operation and noise. If any faults are found, it will affect the use of the guide rail hydraulic lifting platform. When refueling, the hydraulic oil should be filtered and filled, and the refueling tools should be reliable and clean. The hydraulic cargo elevator manufacturer should not remove the filter at the fuel tank filler to improve the refueling speed. Refueling personnel should use clean gloves and work clothes to prevent solid and fiber impurities from falling into the oil.

Sales Department.If the circuit of the device is not disconnected or lowered,Nuremberg Large hydraulic lifting platform, it is necessary to check the fuse for repair and replacement.

On the other hand, under the action of high pressure, the hydraulic system inevitably causes the hydraulic valve to flow back or the sealing components to produce oil. The main reasons for the natural descent of the hydraulic cargo elevator include the following points: replacement of the support valve due to leakage. The lowering valve is damaged or not powered on. Require the lowering valve to be kept clean on a daily basis, and if damaged, replace it with a new hydraulic lowering valve in a timely manner.

When disassembling and adjusting the reverse organization of the equipment, attention should be paid to ensuring that the centerline of the reverse organization reducer is parallel to the centerline of the gear, and its meshing surface is not less than 70%. The meshing gap should be appropriate.

Nuremberg .Each brush should be kept clean on its surface,Nuremberg Large hydraulic lifting platform, and the brush pressure should be adjusted to ensure that its area is not less than 50%.

If the circuit of the device is not disconnected or lowered, it is necessary to check the fuse for repair and replacement.

I believe many people want to know about the maintenance issues of guide rail hydraulic lifting platforms, as it is related to their service life. During use, frequently check the connection of each part. If loose, tighten it. When the body is under pressure, the tightness of the connecting bolts of the body should be checked (the pressure state that can be used). All connecting shafts should have split pins and hydraulic cargo elevators should be fully opened.