Guenzburg Hydraulic ladderCan you work at height

announcer:hp530HP141750488 release time:2024-04-18 11:52:57

There is noise inside the hydraulic cylinder. When replacing the hydraulic oil, there was air in the hydraulic cylinder due to an operational error. Under high pressure, it is easy to generate cavitation and high-frequency noise. When the rod is bent or replaced with a new seal, the new seal is too tight, which can also produce significant noise. If it is a problem of tight sealing, the noise can be reduced after running in for a period of time. If the rod is bent, it needs to be corrected. In addition, hydraulic pipelines should use hoses as much as possible, even when arranging pipelines, it can reduce vibration and noise, and the pipelines should avoid dead bends as much as possible.

The cylinder head oil seal is too tight or the rod is bent, which can also cause noise during movement due to other forces. At this point, the oil seal or straightening rod must be replaced in a timely manner.

Guenzburg .The hydraulic system of the fixed lifting platform of the hydraulic cargo elevator is equipped with anti fall and overload safety protection devices, and operation buttons can be set on each floor and the lifting platform workbench to achieve multi-point operation.

The undercut length of the weld mm should not exceed 10% of the weld seam, and the depth should not exceed 0.4mm.

.Optional configuration of fixed lifting platform: The fixed lifting platform can be equipped with auxiliary devices according to usage requirements, such as the safety protection device of the fixed lifting platform; Electrical methods; Form of work platform; Power form, etc. The correct selection of various configurations maximizes the functionality of the lifting platform and achieves effective use.

Before installation, the installation personnel should confirm the infrastructure such as the foundation and shaft pay attention to alignment, leveling, and alignment points, and confirm that the foundation meets the requirements before construction.

New reference wiring diagram 2. Elevator leg noise. Mobile elevators should open the legs before operation. In this case, if the legs lack butter, noise will be generated.


Guenzburg Hydraulic ladderCan you work at height



New reference wiring diagram 2. Elevator leg noise. Mobile elevators should open the legs before operation. In this case,Guenzburg Indoor hydraulic lifting platform car, if the legs lack butter, noise will be generated.

Advantages of geotechnical engineering: There is no need for a computer room above the shaft, and the top floor height can reach over 5 meters.

There is a phenomenon of self stopping when running up and down. Due to poor contact of the safety protection switch it is easy for hydraulic cargo elevator manufacturers to cause this problem.

Quotation sheet.After 5000 hours of elevator operation, carry out medium maintenance on the mechanical and electrical systems.

The precautions to consider when selecting a hydraulic lift oil tank include: considering the structure of the oil tank, the partition in the traditional oil tank cannot settle dirt. A vertical partition should be installed along the longitudinal axis of the oil tank, with a space left between one end of the partition and the end plate of the oil tank to connect the gaps on both sides of the partition. The inlet and outlet of the hydraulic pump are arranged on both sides of the partition at the disconnected end, so that the distance Z between the inlet and return oil is far, The hydraulic oil tank has more heat dissipation effect.

There is noise inside the hydraulic cylinder. When replacing the hydraulic oil, there was air in the hydraulic cylinder due to an operational error. Under high pressure, it is easy to generate cavitation and high-frequency noise. When the rod is bent or replaced with a new seal, the new seal is too tight, which can also produce significant noise. If it is a problem of tight sealing, the noise can be reduced after running in for a period of time. If the rod is bent, it needs to be corrected. In addition, hydraulic pipelines should use hoses as much as possible, even when arranging pipelines, it can reduce vibration and noise, and the pipelines should avoid dead bends as much as possible.


Guenzburg Hydraulic ladderCan you work at height



Pay attention to checking each steel wire rope for signs of broken wires and loose drums. If it exceeds the relevant rules, it is necessary to replace it immediately. The protection of steel wire ropes should strictly follow the rules of GB5144-85.

Respect for customers.The elevator itself has a simple structure and is easy to maintain, which has been favored by a large number of enterprises and individual customers. Hydraulic elevator is a multifunctional heavy loading and unloading mechanical equipment. The lifting system of hydraulic elevators is driven by hydraulic pressure, also known as hydraulic powered elevators.

If any problems are found,Guenzburg Customized hydraulic lifting platform, please contact the manufacturer in a timely manner to avoid exceeding the warranty period.

After long-term use of the automatic lifting platform equipment, it is inevitable that some malfunctions will occur. In order not to affect work, it is necessary to promptly solve the difficulties in starting the motor and abnormal sounds. Generally, due to overload,Guenzburg Hydraulic lifting platform and hydraulic lifting platform, and a small cross-sectional area of the power supply cable, there should be a safety rope to prevent the workbench from falling out of control. (Allow controlled descent)

The installation personnel should have the qualification for installing hydraulic cargo elevators, carefully implement the special construction plan for installation and construction, and provide safety technical disclosure to the installation personnel for technical design.

The hydraulic lifting platform often checks the connection status of each part, and if there is any looseness it should be tightened. The connection bolts of the machine body should be checked for tightness when the elevator body is under pressure (the compression condition can be formed by rotating the arm). All connecting shafts need to have split pins and need to be fully opened.