PingluManual hydraulic lifting platformInternet marketing brings new opportunities for development

announcer:hp530HP141750488 release time:2024-04-11 09:43:01

PingluPlatform hydraulic lifting,

Regularly inspect the hydraulic lifting equipment of the upper and lower materials to ensure the safety of the rail type elevator and the safety of the material supply to the rail type lifting platform.

Next, the hydraulic cargo elevator manufacturer will explain the maintenance of the mechanical equipment of the elevator: the brakes of each organization should be frequently checked and adjusted to ensure the clearance between the brake pads and wheels is sensitive and reliable. On the surface, there should be no dirt present. If there is dirt, it is necessary to wash it off with gasoline or thinner.

Pinglu.The manufacturer of hydraulic cargo elevators tells you the precautions for high-altitude operations.

The characteristics of the platform include reliable hydraulic system, simple operation, large load-bearing capacity and rear hinge support.

.Hydraulic elevator manufacturers remind us that the basic principle of the hydraulic elevator speed control circuit is that the system often needs to adjust the movement speed of the hydraulic cylinder and hydraulic motor to adapt to the working cycle needs of the main machine. The speed of hydraulic cylinders and hydraulic motors depends on the displacement and input flow rate. It can be seen that changing the flow rate or displacement can affect the speed of the cylinder and motor.

Pre install equipment, maintain unobstructed access roads and sufficient parking space before pre installation. Some hydraulic cargo elevators require heavy lifting assistance for installation some require equipment such as forklifts for installation, and some can be pre installed manually. When it is necessary to install with the assistance of a truck crane and a forklift, full consideration should be given to whether the on-site environment meets the working conditions of the truck crane.

The manufacturer of the hydraulic cargo elevator tells you the reason and cleaning method: Reason: Overload cleaning method: Reduce the load to clean. Reason: The return valve is not closed. Cleaning method: Tighten the return valve to clean. Reason: The one-way valve of the manual pump is stuck and the return valve is malfunctioning. Cleaning method: Unscrew the bolt at the valve port of the oil pump, conduct maintenance, cleaning, and replace the cleaning hydraulic oil to clean.


PingluManual hydraulic lifting platformInternet marketing brings new opportunities for development



The noise and oil level of the elevator oil cylinder are too low. From the air at the connection of the oil filter or joint to the oil, the coupling inside the oil cylinder is loose. The internal fault of the oil cylinder is that the installation of the oil cylinder motor is not concentric. From the motor, the air and oil at the moving shaft are blocked. The oil return pipe of the oil filter is loose, Mixing air into the oil to eliminate: The concentricity should be adjusted to within 0.1MM. The coupling should be repaired or the oil pump should be replaced to increase the oil volume above 400mm in the oil filter and joint positions. The rotating shaft sealing ring should be replaced to clean the oil filter screen, filter the oil, lock the return oil pipeline, and extend the return oil pipeline below the oil level. If there is air mixed in the oil or the air in the hydraulic cylinder is not completely discharged, it will cause cavitation under high pressure and cause significant noise. At this point, it is necessary to exhaust the air in a timely manner.

It must be abnormal. To solve the problem the first step is to identify the cause of the problem. Professional elevator manufacturers have strict testing, quality assurance, and promotional activities are ongoing. Welcome to consult

Protective device: In case of power or oil circuit failure, there should be a safety rope to prevent the workbench from falling out of control. (Allow controlled descent)

Quality inspection report.The electromagnetic coil of the electromagnetic directional valve is not firmly fixed, and frequent separation and suction can also produce high noise.

Due to damage to the gear pump of the lifting cargo elevator equipment and no pressure lifting. Replace the gear pump.

What are the methods for reducing shaking on lifting platforms? Reducing the shaking of the lifting platform can reduce the psychological obstacles of the operators, ensure the smooth progress of the operation, and also greatly help improve safety. Warm reminder: safety, do not operate blindly. Lifts are widely used in many places, and their working principles vary. Today, we will analyze the working principles of elevators. The types of elevators are generally divided into the following: fixed elevators This type of elevator uses hydraulic oil cylinders and pump stations to transmit power, the length of the support rod for the scissor fork, the number of layers, the angle of the angle axis, and the expansion and contraction of the oil cylinder complete the lifting operation. Its advantages are large load-bearing capacity, and high safety.


PingluManual hydraulic lifting platformInternet marketing brings new opportunities for development



The hydraulic pump produces noise. When the hydraulic elevator rises, the hydraulic pump runs at high speed. If there is a problem with the gears or bearings of the hydraulic pump, it will also cause resonance in the hydraulic system and generate noise.

Free consultation.The speed circuit is the circuit that switches the motion speed and speed of the actuator in the hydraulic system of the guide rail hydraulic lifting platform. Mainly including valves, pumps, and actuators. The commonly used speed circuits include speed circuits, high-speed circuits,PingluManufacturer of scissor lift, and speed switching circuits.

Due to the formation of a flow closed-loop, the volumetric speed regulation hydraulic elevator has good performance and high load stiffness. The hydraulic system using the volumetric speed regulation scheme has a higher efficiency and greater energy loss compared to the throttling scheme, as its output power is roughly equal to the power required for the elevator to move up. But using an elevator volume speed control system can only reduce the energy consumption during the upward process of the elevator. When the elevator goes down, the oil in the cylinder moves down the throttle valve under pressure, which will cause the temperature of the hydraulic system to rise. Not to mention anything else, just an intelligent alarm is enough to demonstrate the true value of hydraulic elevators.

Pre install equipment, maintain unobstructed access roads and sufficient parking space before pre installation. Some hydraulic cargo elevators require heavy lifting assistance for installation, some require equipment such as forklifts for installation, and some can be pre installed manually. When it is necessary to install with the assistance of a truck crane and a forklift, full consideration should be given to whether the on-site environment meets the working conditions of the truck crane.

Pinglu.The smoothness of the gearbox, gearbox, external meshing gears, and hydraulic oil are all carried out according to the requirements in the smoothness table.

Remove the hydraulic oil tank filler cap, filter cover, inspection hole, hydraulic oil pipe and other parts to avoid dust when removing the system oil pipe. Clean the disassembled parts before opening them. When disassembling the hydraulic oil tank filler cap, first remove the soil around the tank cap, loosen the tank cap, and remove any remaining debris from the joint (do not rinse with water to prevent water from seeping into the tank). After confirming cleaning, open the tank cap.

The hydraulic elevator overflow valve can also generate high noise. When air is mixed in hydraulic oil, the overflow valve is stuck or severely worn,PingluTwo ton hydraulic lifting platform, the spring of the overflow valve is fatigued and deformed, resulting in unstable pressure regulation of the overflow valve, and the relief time of the overflow valve is too short, it is easy to cause the pilot valve performance of the overflow valve to be partially stable, causing air to vibrate inside the pilot valve and generate noise. So we need to regularly clean the overflow valve. When the overflow valve is damaged or severely worn, it should be replaced.