ToulonFixed hydraulic lifting platformProfessional enterprise

announcer:hp530HP141750488 release time:2024-03-26 13:22:23

Considering the oil level in the oil tank, when all hydraulic cylinders in the system are extended, the oil level in the oil tank should not be lower than the Z-low oil level, and when the oil cylinders retract, the oil level should not be higher than the Z-high oil level. In fact, most manufacturers have noticed the above issues. The reason for the introduction is that most users can learn more about the equipment itself when using elevators, in order to facilitate equipment maintenance. Hydraulic cargo elevator manufacturers sincerely hope that you choose a legitimate manufacturer when purchasing elevators to avoid any worries about after-sales service.

The electromagnetic coil of the electromagnetic directional valve is not firmly fixed, and frequent separation and suction can also produce high noise.

Toulon.Operating cost advantage: Low failure rate: Due to the use of hydraulic systems and good methods,ToulonTwo ton hydraulic lifting platform, the failure rate of elevator operation can be reduced to a low level.

When the hydraulic system malfunctions, the hydraulic elevator may experience problems with the hydraulic pump, motor, valve, and hydraulic installation after repairing the hydraulic system, which can easily cause vibration and generate significant noise.

.Therefore, the wholesale manufacturers of hydraulic elevators remind that there are three main ways to adjust the speed control circuit: throttling speed control circuit: quantitative pump oil supply, using flow valves to adjust the flow in and out of the actuator to achieve speed control; In the volume throttling speed control circuit, the oil is supplied by the pressure limiting variable pump, and the flow rate into the actuator is adjusted by the flow valve to adapt the flow rate of the variable pump to the regulated flow rate of the speed control valve.

Ensure that there is a suitable power supply at the installation site, and separate maintenance of the distribution box is required. The distribution box should have a leakage switch, and the hydraulic cargo elevator construction site should be equipped with a fire extinguisher to prevent welding operations from causing fires. When selecting a leakage switch, it should be suitable for the operating power.

When using hydraulic elevators, frequent inspections and maintenance should be carried out, which not only extends the service life of the hydraulic elevator, but also enables it to exert greater power during operation. Of course, hydraulic elevators also have their own regular repair times and protection methods: regular protection (carried out per shift).


ToulonFixed hydraulic lifting platformProfessional enterprise



The contact of the travel switch must be firmly opened and closed, first connect the power supply and press the button to drive the motor of the hydraulic power unit to drive the gear pump. The hydraulic oil forms a certain pressure through the vane pump and passes through the oil filter; Explosion proof electromagnetic directional valve; Throttle valve; Hydraulic control one-way valve; The balance valve enters the lower end of the hydraulic cylinder,ToulonHydraulic lifting platform supplier, causing it to move upwards and lift heavy objects. The hydraulic cylinder moves downwards (i.e. the weight drops), the explosion-proof electromagnetic directional valve of the hydraulic oil enters the upper end of the hydraulic cylinder, and the return oil from the lower end of the hydraulic cylinder passes through the balance valve; Hydraulic control one-way valve; Throttle valve, pumps, and actuators. The commonly used speed circuits include speed circuits, high-speed circuits, and speed switching circuits.

Recommendation and consultation.The classification of lifting platforms is as follows: they are divided into mobile lifting platforms, automatic lifting platforms, hydraulic lifting platforms, folding arm lifting platforms and sleeve type lifting platforms according to their different modes of movement.

Regularly inspect the hydraulic lifting equipment of the upper and lower materials to ensure the safety of the rail type elevator and the safety of the material supply to the rail type lifting platform.

Considering the oil level in the oil tank, when all hydraulic cylinders in the system are extended,ToulonLarge hydraulic lifting platform, the oil level in the oil tank should not be lower than the Z-low oil level, and when the oil cylinders retract, the oil level should not be higher than the Z-high oil level. In fact, most manufacturers have noticed the above issues. The reason for the introduction is that most users can learn more about the equipment itself when using elevators, to avoid any worries about after-sales service.


ToulonFixed hydraulic lifting platformProfessional enterprise



The speed circuit is the circuit that switches the motion speed and speed of the actuator in the hydraulic system of the guide rail hydraulic lifting platform. Mainly including valves, pumps, and actuators. The commonly used speed circuits include speed circuits, high-speed circuits, and speed switching circuits.

Focus on Development.The cylinder head oil seal is too tight or the rod is bent, which can also cause noise during movement due to other forces. At this point, the oil seal or straightening rod must be replaced in a timely manner.

The hydraulic pump also has an impact on the flow rate of hydraulic oil. If the hydraulic pump is used for a long time, it is also prone to problems. When the speed of the hydraulic lifting table slows down, it is necessary to check whether the oil supply of the hydraulic pump is firm and firm.

Hydraulic elevator manufacturers remind us that the basic principle of the hydraulic elevator speed control circuit is that the system often needs to adjust the movement speed of the hydraulic cylinder and hydraulic motor to adapt to the working cycle needs of the main machine. The speed of hydraulic cylinders and hydraulic motors depends on the displacement and input flow rate. It can be seen that changing the flow rate or displacement can affect the speed of the cylinder and motor.

Toulon.Voltage too low: Measure the starter voltage, and the oil temperature is between 45~80 ℃. Use a large flow rate to remove impurities from the system as much as possible. The hydraulic system needs to be cleaned repeatedly three times or more, and after each cleaning the system should be drained while the oil is hot. After cleaning, clean the filter and add new oil after using a new filter element.

The characteristics of the platform include reliable hydraulic system, simple operation, large load-bearing capacity, and rear hinge support.