HaLarge hydraulic lifting platformOffer summary

announcer:hp530HP141750488 release time:2024-02-25 09:01:19

The precautions to consider when selecting a hydraulic lift oil tank include: considering the structure of the oil tank, with a space left between one end of the partition and the end plate of the oil tank to connect the gaps on both sides of the partition. The inlet and outlet of the hydraulic pump are arranged on both sides of the partition at the disconnected end, so that the distance Z between the inlet and return oil is far, The hydraulic oil tank has more heat dissipation effect.

Protective device: In case of power or oil circuit failure, there should be a safety rope to prevent the workbench from falling out of control. (Allow controlled descent)

Ha.This product has a solid structure, high load-bearing capacity, smooth lifting, easy installation and maintenance, and is an ideal cargo transportation equipment for replacing elevators on lower floors.

Reason: The lowering speed valve is out of adjustment. Cleaning method: If the lowering speed valve is adjusted, and if the adjustment is ineffective, replace it with a new valve.

.Car mounted lifting platform: The car mounted lifting platform is designed to improve the mobility of the lifting platform by fixing it to a transport vehicle or truck. It receives power from the car engine and achieves the lifting function of the car mounted lifting platform. To adapt to high-altitude operations inside and outside the factory area.

When disassembling and adjusting the reverse organization of the equipment, attention should be paid to ensuring that the centerline of the reverse organization reducer is parallel to the centerline of the gear,HaGuide rail hydraulic lifting platform, and its meshing surface is not less than 70%. The meshing gap should be appropriate.

Solution: Check if the performance of the legs is good, even if the butter is polished to increase its properties.


HaLarge hydraulic lifting platformOffer summary



The precautions to consider when selecting a hydraulic lift oil tank include: considering the structure of the oil tank, the partition in the traditional oil tank cannot settle dirt. A vertical partition should be installed along the longitudinal axis of the oil tank, with a space left between one end of the partition and the end plate of the oil tank to connect the gaps on both sides of the partition. The inlet and outlet of the hydraulic pump are arranged on both sides of the partition at the disconnected end, so that the distance Z between the inlet and return oil is far, The hydraulic oil tank has more heat dissipation effect.

The manufacturer of hydraulic cargo elevators tells you the precautions for high-altitude operations.

When disassembling and adjusting the reverse organization of the equipment, attention should be paid to ensuring that the centerline of the reverse organization reducer is parallel to the centerline of the gear and its meshing surface is not less than 70%. The meshing gap should be appropriate.

install.Lines of various safety equipment

The installation personnel should confirm and count the equipment details, check if the tools are complete confirm that there are no omissions in the shipped equipment details, the location of the platform should be selected to minimize the distance of the handling tools and vehicles in the factory. It is much easier to move a fully loaded transport vehicle to a designated location outside the building than to transport the loaded materials one by one to the designated location indoors. When selecting a platform location, full consideration should be given to the production process and operational needs of the factory. There are two modes of platform layout: merging: loading and unloading on the same platform.


HaLarge hydraulic lifting platformOffer summary



The noise and oil level of the elevator oil cylinder are too low. From the air at the connection of the oil filter or joint to the oil,HaHydraulic small lifting platform, the coupling inside the oil cylinder is loose. The internal fault of the oil cylinder is that the installation of the oil cylinder motor is not concentric. From the motor, the air and oil at the moving shaft are blocked. The oil return pipe of the oil filter is loose, and the air or oil pipe is on the oil surface Mixing air into the oil to eliminate: The concentricity should be adjusted to within 0.1MM. The coupling should be repaired or the oil pump should be replaced to increase the oil volume above 400mm in the oil filter and joint positions. The rotating shaft sealing ring should be replaced to clean the oil filter screen, filter the oil, lock the return oil pipeline, and extend the return oil pipeline below the oil level. If there is air mixed in the oil or the air in the hydraulic cylinder is not completely discharged, it will cause cavitation under high pressure and cause significant noise. At this point, it is necessary to exhaust the air in a timely manner.

Supply chain quality management.The hydraulic lifting platform is a manually movable type, and the lifting power of the platform is a two machine or three-phase power supply. It has manual and electric power, and is also equipped with a hand pump for use in case of power outage. This series of platforms have the characteristics of flexible movement,HaHydraulic automatic lifting platform, stable lifting, and easy operation, and are mainly used in factories, government agencies, commercial stores, which improves the utilization rate of the well surface.

Regularly inspect the hydraulic lifting equipment of the upper and lower materials to ensure the safety of the rail type elevator and the safety of the material supply to the rail type lifting platform.

Ha.Volume speed control circuit: Speed control is achieved by adjusting the displacement of a variable pump or variable motor.

After 10000 hours of operation on the hydraulic lift, major repairs will be carried out to the mechanical and electrical systems.

The main device does not engage. When this fault occurs, check whether the three-phase power supply is normal, whether the internal and external emergency stop button switches, the electric lock switch are turned on, whether the three-phase electrical phase sequence is correct, and whether the relay working indicator light is on.