HuairenCustomized hydraulic lifting platformWhat are the tools and quality requirements of the production line?

announcer:hp530HP141750488 release time:2024-01-29 09:51:25

HuairenIndoor hydraulic lifting platform,

Protective device: In case of power or oil circuit failure, there should be a safety rope to prevent the workbench from falling out of control. (Allow controlled descent)

The speed circuit is the circuit that switches the motion speed and speed of the actuator in the hydraulic system of the guide rail hydraulic lifting platform. Mainly including valves, pumps, and actuators. The commonly used speed circuits include speed circuits, high-speed circuits, and speed switching circuits.

Huairen.Below, we will analyze for everyone. According to the market survey and understanding conducted by the editor of hydraulic freight elevator manufacturers, many customers choose hydraulic elevators instead of elevators due to the following reasons: narrow transportation location, which cannot meet the requirements of elevators; Unable to excavate the elevator shaft at the working location; Elevators are expensive and difficult to meet their needs.

When using hydraulic elevators,Huairen3 ton hydraulic lifting platform, frequent inspections and maintenance should be carried out, which not only extends the service life of the hydraulic elevator, but also enables it to exert greater power during operation. Of course, hydraulic elevators also have their own regular repair times and protection methods: regular protection (carried out per shift).

.A hydraulic elevator is a type of elevator equipment consisting of a walking mechanism, hydraulic mechanism, electric mechanism, and support mechanism. The hydraulic oil forms a certain pressure by the vane pump, and enters the lower end of the hydraulic cylinder through an oil filter, explosion-proof electromagnetic directional valve, hydraulic control one-way valve, causing the hydraulic cylinder to move upwards and lift heavy objects. The return oil at the upper end of the hydraulic cylinder returns to the oil tank through the explosion-proof electromagnetic directional valve, and its rated pressure overflow valve is adjusted. The pressure gauge observes the reading value on the pressure gauge.

The hydraulic oil used in the system has the same brand and the oil temperature is between 45~80 ℃. Use a large flow rate to remove impurities from the system as much as possible. The hydraulic system needs to be cleaned repeatedly three times or more, and after each cleaning, the system should be drained while the oil is hot. After cleaning, clean the filter and add new oil after using a new filter element.

The noise and oil level of the elevator oil cylinder are too low. From the air at the connection of the oil filter or joint to the oil the coupling inside the oil cylinder is loose. The internal fault of the oil cylinder is that the installation of the oil cylinder motor is not concentric. From the motor, the air and oil at the moving shaft are blocked. The oil return pipe of the oil filter is loose, and the air or oil pipe is on the oil surface, Mixing air into the oil to eliminate: The concentricity should be adjusted to within 0.1MM. The coupling should be repaired or the oil pump should be replaced to increase the oil volume above 400mm in the oil filter and joint positions. The rotating shaft sealing ring should be replaced to clean the oil filter screen, filter the oil, lock the return oil pipeline, and extend the return oil pipeline below the oil level. If there is air mixed in the oil or the air in the hydraulic cylinder is not completely discharged, it will cause cavitation under high pressure and cause significant noise. At this point, it is necessary to exhaust the air in a timely manner.


HuairenCustomized hydraulic lifting platformWhat are the tools and quality requirements of the production line?



Next, the hydraulic cargo elevator manufacturer will explain the maintenance of the mechanical equipment of the elevator: the brakes of each organization should be frequently checked and adjusted to ensure the clearance between the brake pads and wheels is sensitive and reliable. On the surface, there should be no dirt present. If there is dirt, it is necessary to wash it off with gasoline or thinner.

All high-altitude operations must first build scaffolding or take measures to prevent teams from falling before boarding the vehicle bridge.

Users should arrange dedicated personnel to operate hydraulic elevators, formulate usage details and safety precautions for hydraulic elevators based on their own situation, and hang them on the

Quality risk.Each box, distribution box, etc. should be kept clean and promptly cleaned of dust on electrical equipment.

The hydraulic oil used in the system has the same brand, and the oil temperature is between 45~80 ℃. Use a large flow rate to remove impurities from the system as much as possible. The hydraulic system needs to be cleaned repeatedly three times or more, and after each cleaning, the system should be drained while the oil is hot. After cleaning clean the filter and add new oil after using a new filter element.

The installation personnel should confirm and count the equipment details, confirm that there are no omissions in the shipped equipment details, check if the tools are complete and ensure the smooth progress of the installation process.


HuairenCustomized hydraulic lifting platformWhat are the tools and quality requirements of the production line?



The elevator is evenly distributed at any position on the guide rail at 150% of the maximum load capacity, and should be stable at the maximum lifting height.

Application process.Lines of various safety equipment

There are two reasons for the sinking of the hydraulic cargo elevator table: on the one hand, the hydraulic pressure is flexible, and under high pressure or temperature,Huairen8-meter hydraulic lifting platform, the volume will change, which is reflected in the lowering of the position on the table.

The lifting platform is placed on a horizontal support surface, and the concentrated load of MAX load capacity is placed at any position 300mm away from the periphery of the workbench. After lifting 100 times, draw on the guide rail lifting platform, prohibit any idle personnel from entering the work area, ensure that the work area is free of clothing, and maintain a clean and tidy workplace.

When using an electric mobile scissor lifting platform outdoors, if the wind force exceeds level 5, the wind ropes at the four corners of the hydraulic lift platform should be tightened and fixed, and the support legs should be reinforced for protection and stability to avoid safety accidents caused by excessive swinging of the electric lifting platform