the bracket should be supported to prevent the electric elevator from overturning. Electrical and hydraulic systems should be maintained by professional personnel; When the battery level display is less than 40%

The quality of the standard section should comply with the product manual and specification requirements.

.Setting requirements: The wall bracket should use the manufacturer's matching standard products.

Setting requirements: Drainage measures should be set up for the foundation of construction electric elevators to ensure smooth drainage.

The entrance of each landing platform must be equipped with a landing door

The end height of the guide rail frame above the high attachment point should comply with the provisions of the user manual.

Construction electric elevators should be equipped with cable guide frames and comply with regulatory requirements.

Henderson.Electric elevators should be regularly maintained and cleaned. During maintenance and cleaning, which must open towards the landing platform side,HendersonElectric small elevator,HendersonFixed electric elevator,HendersonElectric elevator 5 meters, and the door bolt must be set on the side next to the construction electric elevator.


HendersonSecond floor electric elevatorIndustrial Development



Setting requirements: The verticality deviation of the installation of the guide rail frame of the construction electric elevator should comply with the requirements of the user manual and specifications, as specified in the above table.

Non automatic reset upper and lower limit switches should be installed at both the upper and lower ends of the stroke, which should be able to cut off the power supply before the suspension cage and other mechanical stop devices (such as buffers),

Protective measures should comply with regulatory requirements.

where.Model Example: Hanging Cage Specification: LABSC200/200TD3200x1500 Type I: 2900~3600 Type II: 2900~3600 Type V: 1800~250044003800 Technical Requirements: The load-bearing capacity of the foundation should be greater than P: P=(hanging cage weight+outer cage weight+total weight of guide rail frame+counterweight+load) x0.02 (kN).

Setting requirements: For construction electric elevators that operate in multiple shifts, and the difference between the net width and the outlet width of the cage door should not exceed 120mm. When the floor door is closed and drivers should fill out the handover record form according to the standard requirements. The driver should conduct a pre shift inspection and confirm that there are no errors before starting the machine for operation.

The net height of the landing door opening should not be less than 8m, except for the gap between the lower part of the door that should not exceed 35mm, the size of any through-hole and opening related to the distance between any door and adjacent moving parts, as well as the gap around the door or between parts, should comply with the provisions of Table 4 of 'Mechanical Safety - Safety Distance to Prevent Upper and Lower Limbs from Touching Dangerous Areas' GB23821-2009.


HendersonSecond floor electric elevatorIndustrial Development



The list of materials for making landing doors is as follows: Table 1: List of materials for making landing doors. Landing doors should be installed at the entrance of each landing station, and the landing doors should function properly.

how much.The hydraulic oil forms a certain pressure by the vane pump, and enters the lower end of the hydraulic cylinder through an oil filter, explosion-proof electromagnetic directional valve, throttle valve, hydraulic control one-way valve, and balance valve, causing the hydraulic cylinder to move upwards and lift heavy objects. The return oil at the upper end of the hydraulic cylinder returns to the oil tank through the explosion-proof electromagnetic directional valve, and its rated pressure overflow valve is adjusted. The pressure gauge observes the reading value on the pressure gauge. The downward movement of the hydraulic cylinder (i.e. lowering of heavy objects).

Setting requirements: The up travel (limit) switch should be able to automatically stop the cage running at the rated speed before reaching the upper limit switch, but should not trigger the up travel (limit) switch as high

The hydraulic oil enters the upper end of the hydraulic cylinder through the explosion-proof electromagnetic directional valve, and the return oil from the lower end of the hydraulic cylinder returns to the oil tank through the balance valve, hydraulic control one-way valve, and explosion-proof electromagnetic directional valve. To ensure a smooth descent of heavy objects and safe and reliable braking, a balance valve is installed on the return oil circuit to balance the circuit and maintain pressure, so that the descent speed does not change due to heavy objects. The throttle valve regulates the flow rate and the ascending and descending speed.

Henderson.The connection method and angle between the wall bracket and the building structure should comply with the requirements of the user manual.

Setting requirements: The wall bracket should use the manufacturer's matching standard products.

The L distance depends on the selected wall mount model.