KaiserslauternFolding electric elevatorTechnical methods in wall protection

announcer:hp935HP175192871 release time:2023-12-19 09:53:28

Buffer. In order to increase the energy for the car to hit the top or sink to the bottom. Remove rubber or sponge from the buffer and cabin to increase their impact energy; Rope groove slipping and other accidents caused the car to suddenly fall, resulting in a safety clamp. To prevent breakage of the lifting wire rope. A safety clamp that can simultaneously cut off the power supply and stop the car from falling should be removed from the car. A car without safety tongs is not allowed to ride or carry people. If it is a simple electric elevator,KaiserslauternNiuli brand electric elevator, there should be a safety device (such as a safety stop pin) to prevent people from suddenly falling when loading and unloading goods in the car; Electric elevators with three or more floors (including three floors) for passengers or passengers.

When the horizontal distance between the edge of the cage and the edge of the landing or between the cage and the landing door is greater than 150mm and there is no effective protection from other structures, the side protection device for the landing entrance should be equipped.

Kaiserslautern.Unloading platform and attached electric construction platform, etc.

During loading and unloading, the horizontal distance between the edge of the cage door and the edge of the landing station should not exceed 50mm.

.Low level doors should be equipped with interlocking devices that can verify their closed and locked positions. The action of this interlocking device should be at the entrance of the cage. Simple use should not interfere with the operation of the interlocking device. The attached wall bracket should use matching standard products. When the wall bracket cannot meet the requirements of the construction site, it should be designed separately. The design of the wall bracket should meet the requirements of component stiffness, stability, etc., and the production should meet the design requirements.

During normal operation, the horizontal distance between the closed cage door and the closed landing door should not exceed 150mm. Otherwise, measures should be taken to make it meet the requirements, or side protection devices at the entrance of the landing station that meet the requirements should be equipped. The distance between any opening between the side protection device and the hanging cage or landing door should not exceed 150mm.

The setting of the cable guide frame should comply with the user manual and regulatory requirements.


KaiserslauternFolding electric elevatorTechnical methods in wall protection



In order to meet the needs of contemporary audiences and achieve perfect effects, in addition to lighting and sound, stage machinery is particularly important on the stage. On the stage, there are suspension rods, suspension points, lighting bridges, lighting suspension cages,KaiserslauternHigh altitude electric elevator, and fire curtains. Under the stage, there are lifting platforms, car platforms, turntables, and lifting orchestras. Some lifting platforms are equipped with turntables, or there are lifting platforms in the turntables. Various types of lifting platforms are equipped in professional opera houses, dance theaters, drama theaters, and many internationally renowned music halls. It has the functions of quickly changing scenery meeting the needs of stage craft layout, meeting the needs of stage design and choreographers creating special atmosphere and effects, and changing the stage form according to the needs of the performance.

Check the starter potential when the lifting table is not raised or the voltage is too low when the motor load is working. Voltage hydraulic range allowed&

Especially suitable for steel structured factories, suitable for both indoor and outdoor installation.

Word of mouth recommendation.The function of the lifting platform in a theater is roughly as follows: the main lifting platform arranged in the main performance area of the stage is mainly used to quickly change the scenery. Typically, with&quo; Product; In the music and dance theater stage arranged in a zigzag pattern, the lifting platform, side car platform, and rear car turntable perform a rapid transformation of the entire or partial scene. This arrangement allows for rapid switching of three full sets.

Then, the lifting platform platform platform that carries the load needs to be balanced, and no deviation of one side is allowed. The lifting of goods does not allow people to stand on both sides of the platform, and the lifting of goods should try to maintain a stable and uniform speed.

Small safe operation distance: Circuit voltage (kV) of external power lines<11~1035~110220330~550 Small safe operation distance (m) 4681015 Setting requirements: A small safe distance should be maintained between the outer edge of the construction electric elevator and the edge of the external overhead power line.


KaiserslauternFolding electric elevatorTechnical methods in wall protection



The bearing capacity of the ground under the concrete foundation plate should be greater than 0.15Mpa.

OK or not?.The setting of the cable guide frame should comply with the user manual and regulatory requirements.

The detailed reason why water cannot be used to flush the hydraulic station is that doing so will corrode the oil tank in the hydraulic station, and once water is mixed in the hydraulic station, the damage to the hydraulic system is very large. Therefore, water vaporization, and other phenomena that can cause adverse effects or results for hydraulic electric elevators. Therefore, it is necessary to prevent such actions to ensure the normal operation and service life of the hydraulic station.

The safety bulletin board for construction electric elevators should be hung at the protective shed of the electric elevator,KaiserslauternLarge electric elevator, with a size of 8 meters by 2 meters.

Kaiserslautern.Setting requirements: For construction electric elevators that operate in multiple shifts, the handover system should be implemented and drivers should fill out the handover record form according to the standard requirements. The driver should conduct a pre shift inspection and confirm that there are no errors before starting the machine for operation.

The safety bulletin board for construction electric elevators should be hung at the protective shed of the electric elevator, with a size of 8 meters by 2 meters.

Installation verticality deviation guide rail frame erection height, the verticality deviation of the guide rail frame should not exceed (5/1000) h.