MadisonElevator electric elevatormarket price

announcer:hp935HP175192871 release time:2024-08-01 13:10:53

High lifting height, using side mounted oil cylinders, stable operation, noise free, easy maintenance, and longer service life.

Especially suitable for steel structured factories,MadisonElectric elevator 200kg,MadisonSmall electric mobile elevator, suitable for both indoor and outdoor installation.

Madison.Installation position of upper limit switch: Under normal working conditions, the distance between the upper limit switch and the upper limit switch is 0.15m for SC type construction electric elevators, and 0.15m for SS type construction electric elevators (person)

Buffer. In order to increase the energy for the car to hit the top or sink to the bottom. Remove rubber or sponge from the buffer and cabin to increase their impact energy; Rope groove slipping and other accidents caused the car to suddenly fall, resulting in a safety clamp. To prevent breakage of the lifting wire rope. A safety clamp that can simultaneously cut off the power supply and stop the car from falling should be removed from the car. A car without safety tongs is not allowed to ride or carry people. If it is a simple electric elevator, there should be a safety device (such as a safety stop pin) to prevent people from suddenly falling when loading and unloading goods in the car; Electric elevators with three or more floors (including three floors) for passengers or passengers.

.Speed limit wire rope switch. When the speed limit wire rope trips or breaks. Make the electric elevator unable to start.

Principle of electric elevator rotary valve: When the electric elevator rises, the rotary valve will automatically open. To close the plug valve,MadisonFolding electric elevator, it is necessary to first turn the handle to turn the plug to a 90 degree position until it is closed, and then turn the transmission handwheel to lower the plug and achieve sealing.

When a rigid 5000mm2 square or circular flat surface is applied with a normal force of 600N to either side of the door, the door may not meet the above requirements, but safety should be maintained.


MadisonElevator electric elevatormarket price



Braking. The brake limit switch for partial motion control of the electric hoist traction machine. Assembly that restricts the operation of the lift car when it is opened to a high or low position; If the limit switch controls the overtravel switch. When the car travels to a high or low position, it will take on the function of raising or lowering. In order to prevent the lift car from crashing or sinking, stage equipment should be dismantled with over travel switches that can cut off power and cannot be automatically reset, and installed in the machine room, rather than in the shaft; A buffer should be installed that can absorb the energy of the moving mechanism and reduce impact.

Construction electric elevators should be equipped with safety devices to prevent the cage from falling. The anti fall safety device should be functional at all times, including installation, disassembly, and before resetting after action. Fall arrest safety gear

Before operating the construction electric elevator, routine inspections should be carried out according to regulations and inspection records should be filled out.

Create brilliance.The quality of the standard section should comply with the product manual and specification requirements.

Setting requirements: The wall bracket should use the manufacturer's matching standard products.

Horizontal lead screw mechanical electricity


MadisonElevator electric elevatormarket price



Safety grounding device. In order to protect against electrical equipment. The metal casing of electrical equipment and the metal structure of electric elevators should be equipped with a safety grounding device. The grounding wire should operate multiple wires, and the neutral wire should not be arbitrarily held as a safety grounding wire. Its grounding resistance should not exceed 4 ohms; The power supply of the electric elevator can be cut off.

Meticulous workmanship.When the wall bracket cannot meet the requirements of the construction site it should be designed and calculated separately.

Stop.

From the above comparison, it can be seen that hydraulic electric lifting mechanisms have stable lifting, long service life, large load bearing capacity, and the valve can be opened and closed at any time; The installation of a rotary valve reduces the friction of the sealing components; Compact structure making them suitable for use in stage equipment.

Madison.Advantages of electric elevator rotary valve: Simplify the installation of electric elevator pipelines; The operation is more convenient, small size, and space saving; Increased the service life of electric elevator pipelines and solved the problem of easy oil leakage.

The angle between the wall bracket and the horizontal plane should comply with the requirements of the user manual.

The bearing capacity of the ground under the concrete foundation plate should be greater than 0.15Mpa.