AlexandriaMultifunctional electric elevatorSpecification model

announcer:hp935HP175192871 release time:2024-08-01 10:58:19

Once again, weekly inspections should be conducted to check whether the connecting screws at various parts of the lifting platform are tightened, whether the sealing rings are damaged or ineffective, whether there is a lack of hydraulic oil, and whether the oil cylinder is leaking. It is necessary to clean the lifting frame, scissors, wiring, and oil cylinder once a week to avoid dust and debris affecting normal operation.

After the electric elevator passes the inspection, the user unit shall organize the leasing unit, installation unit, the acceptance shall be organized by the construction general contracting unit. The acceptance form should be signed by the relevant responsible person.

Alexandria.The movement of its related components is direct.

When the foundation is set on the roof or floor structure, the bearing capacity of its supporting structure should be checked.

.To meet the needs of choreographers and choreographers in different plays, different heights of the lifting platform can be used to change the shape of the stage according to the requirements of the choreographers and choreographers, and save manpower and material resources for setting up. By using the tilting device of the lifting platform to form a tilted platform, a better highlighting effect can be achieved in various performances. According to the needs of the plot,AlexandriaElectric hydraulic elevator, special atmosphere and effects can be created. Even simple stage machinery often participates in performance activities, creating unexpected atmosphere and effects according to the needs of the plot. For example using the low-speed descent of the lifting platform to represent a sunken ship in the sea, using the valves on the lifting platform and the sudden disappearance and appearance of actors on the lifting platform.

When the wall bracket adopts non matching standard products, design calculations should be carried out.

Every theater is a public place with a large number of people, and safety considerations should be taken into account in stage design. According to relevant national regulations,AlexandriaElectric chain elevator, in order to prevent accidents caused by the crushing of electric elevators or improper control by drivers. Electric elevators should be equipped with the following necessary safety devices to ensure that the car of the electric elevator stops rising or falling in a timely manner.


AlexandriaMultifunctional electric elevatorSpecification model



The function of the lifting platform in a theater is roughly as follows: the main lifting platform arranged in the main performance area of the stage is mainly used to quickly change the scenery. Typically, with&quo; Product; In the music and dance theater stage arranged in a zigzag pattern, side car platform and rear car turntable perform a rapid transformation of the entire or partial scene. This arrangement allows for rapid switching of three full sets.

Setting requirements: A limit switch should be set at both the upper and lower ends of the stroke, which should be able to cut off the power supply before the suspension cage and other mechanical stop devices (such as buffers), so that the suspension cage can stop

When applying a normal force of 300N to any position on either side of the door using a rigid 5000mm2 square or circular flat surface in the locked position of the landing door, the door should be able to withstand and have no deformation; - Deformation not exceeding 30mm; After the test, it worked normally.

Welcome calls .Implementing multiple shifts of homework should fill in and submit records according to regulations.

When the door is closed, except for the gap between the lower part of the door that should not exceed 35mm, any through-hole and opening size related to the distance between any door and adjacent moving parts, as well as the gap around the door or the gap between parts, should comply with the provisions of Table 4 of GB 23821-2009.

The verticality of the guide rail frame should meet the requirements of the specifications.


AlexandriaMultifunctional electric elevatorSpecification model



Setting requirements: Drainage measures should be set up for the foundation of construction electric elevators to ensure smooth drainage.

Welcome to inquire.The L distance depends on the selected wall mount model.

Stop.

When the door is closed, except for the gap between the lower part of the door that should not exceed 35mm, any through-hole and opening size related to the distance between any door and adjacent moving parts, as well as the gap around the door or the gap between parts, should comply with the provisions of Table 4 of GB 23821-2009.

Alexandria.Construction electric elevators should be equipped with cable guide frames and comply with regulatory requirements.

Tank oil temperature protection: When the oil temperature in the tank exceeds the standard setting value,AlexandriaMobile electric elevator, the oil temperature protection device sends a signal to suspend the use of the elevator. The elevator can only be started when the oil temperature drops

When a rigid 5000mm2 square or circular flat surface is applied with a normal force of 600N to either side of the door, the door may not meet the above requirements, but safety should be maintained.