Xiqing8 meter electric elevatorThree common classification standards

announcer:hp935HP175192871 release time:2024-07-28 09:56:47

The verticality of the guide rail frame should meet the requirements of the specifications.

The hydraulic oil enters the upper end of the hydraulic cylinder through the explosion-proof electromagnetic directional valve, and the return oil from the lower end of the hydraulic cylinder returns to the oil tank through the balance valve, hydraulic control one-way valve, throttle valve, and explosion-proof electromagnetic directional valve. To ensure a smooth descent of heavy objects and safe and reliable braking, a balance valve is installed on the return oil circuit to balance the circuit and maintain pressure, so that the descent speed does not change due to heavy objects. The throttle valve regulates the flow rate and the ascending and descending speed.

Xiqing.There is a certain itinerary.

Secondly, the lifting platform is driven by electrical energy and lifted by the hydraulic system. During operation, it is necessary to avoid irregular operations. To ensure the normal and orderly operation of the lifting platform and achieve the ideal unloading level, timely inspection of various functions is essential.

.The scaffolding of the parking platform should be laid tightly and firmly.

Setting requirements: Each landing entrance should be equipped with a landing door,XiqingTwo phase electric elevator, which should cover the opening with its full width, and should not open towards the lifting passage.

The spacing between wall brackets and the height of guide rails above the high attachment point should comply with the requirements of the user manual.


Xiqing8 meter electric elevatorThree common classification standards



The connection method and angle between the wall bracket and the building structure should comply with the requirements of the user manual.

Construction electric elevators must be equipped with lifting cages and reusable buffers, and comply with regulatory requirements.

When the horizontal distance between the edge of the cage and the edge of the landing or between the cage and the landing door is greater than 150mm and there is no effective protection from other structures, the side protection device for the landing entrance should be equipped.

Customer first.From the above comparison, it can be seen that hydraulic electric lifting mechanisms have stable lifting, low noise, long service life, large load bearing capacity, and are relatively simple, making them suitable for use in stage equipment.

As a material loading and unloading equipment recognized by customers in the lifting platform, the guide rail hydraulic lifting platform is superior in terms of product, civil engineering, and operating costs. The editor of the electric elevator will provide a detailed analysis: the advantages of the product are that the equipment bears a large load,Xiqing200 kg electric elevator, can achieve multiple points, and can be controlled up and down floors to achieve safe use.

Chain type electric lifting mechanism: With a good guiding mechanism, it can ensure that the equipment does not tilt during operation. Gear and rack electric lifting mechanism: precise transmission and high cost.


Xiqing8 meter electric elevatorThree common classification standards



During normal operation the horizontal distance between the closed cage door and the closed landing door should not exceed 150mm. Otherwise, measures should be taken to make it meet the requirements, or side protection devices at the entrance of the landing station that meet the requirements should be equipped. The distance between any opening between the side protection device and the hanging cage or landing door should not exceed 150mm.

Professional is king.Small safe operation distance: Circuit voltage (kV) of external power lines<11~1035~110220330~550 Small safe operation distance (m) 4681015 Setting requirements: A small safe distance should be maintained between the outer edge of the construction electric elevator and the edge of the external overhead power line.

The water cooling of hydraulic stations is generally tubular water cooling. The selection is based on the heat load to calculate the heat exchange area, while the air-cooled electric elevator uses an air cooler to calculate the heat exchange capacity based on the heat load. Then, the selection calculation is carried out under the condition of satisfying the flow rate. So, these two types of cooling are different and have significant differences.

It is reported that a fixed electric elevator has good lifting stability and can only be used for fixed operations,XiqingThree phase electric elevator, making high-altitude operations easier

Xiqing.Emergency manual valve: In case of power failure, strength testing report.

Flat screw mechanical electric lifting mechanism: The lifting platform of this structure has the advantages of small civil engineering coordination, large stroke, stable operation low noise, accurate positioning, and low cost. Adopting a horizontal screw drive and a scissor fork structure to achieve the lifting motion of the table