AfragolaElectric hydraulic elevatorPlease choose the right way to use

announcer:hp935HP175192871 release time:2024-06-28 16:19:36

Setting requirements: The verticality deviation of the installation of the guide rail frame of the construction electric elevator should comply with the requirements of the user manual and specifications, as specified in the above table.

The end height of the guide rail frame above the high attachment point should comply with the provisions of the user manual.

Afragola.Afterwards,AfragolaElectric mobile hydraulic elevator, occupying a relatively small area, improving the utilization rate of the wellbore area.

.Construction electric elevators should be equipped with cable guide frames and comply with regulatory requirements.

Safety performance: Electric elevators not only have the safety device of traditional traction elevators, but also have an overflow valve to prevent excessive system pressure during upward movement

It is reported that a fixed electric elevator has good lifting stability and can only be used for fixed operations, making high-altitude operations easier


AfragolaElectric hydraulic elevatorPlease choose the right way to use



Manual pump: When the system malfunctions,AfragolaElectric tricycle hydraulic elevator, the manual pump can be operated to pump high-pressure oil to raise the car to the nearest floor position

The safety overtravel of limit switches and upper limit switches should comply with regulatory requirements.

Human improper operation is the main factor causing malfunctions in scissor type electric elevators. When stacking goods, electric elevators should stack the goods neatly, which is better than stacking them in the center of the cargo stacking area of the cargo elevator to avoid imbalance between the two ends of the stacking area. Eventually, during the operation of the electric elevator, it may cause the electric elevator to lose balance. After the goods are stacked completely, ropes should be used to lock the goods, so that they are not afraid of the goods during the lifting process; Careless; Scattered down

quality index.Setting requirements: When the distance between the outer edge of the construction electric elevator and the external overhead power line cannot meet the requirements of a small safety distance, the protective measures taken should comply with the specification requirements.

Many theaters use a lifting platform as a vertical transportation tool for goods. The rear of the main stage or the end of the side stage in many theaters are equipped with a set container transportation lifting platform, which is used to vertically transport items from the ground to a designated location or even the stage plane. The lifting platform of the music pool is often used for transporting movable seats, measures should be taken to make it meet the requirements the horizontal distance between the closed cage door and the closed landing door should not exceed 150mm. Otherwise, or side protection devices at the entrance of the landing station that meet the requirements should be equipped. The distance between any opening between the side protection device and the hanging cage or landing door should not exceed 150mm.


AfragolaElectric hydraulic elevatorPlease choose the right way to use



Protective measures should comply with regulatory requirements.

Excellent service.The foundation base or embedded parts should be fully embedded in the concrete foundation plate.

The pressure joint between the pipe joint and the rubber hose fails prematurely, causing oil leakage or pipe explosion. The oil temperature rises due to frequent action of the overflow valve.

Setting requirements: The foundation and foundation of the construction electric elevator should meet the requirements of the user manual. Before installing the construction electric elevator, the foundation should be inspected and accepted according to the requirements of the specifications. Only after passing the inspection can the installation be carried out.

Afragola.There is no need to set up a computer room above the shaft like an elevator, and the top floor height can be installed at least 2.5 meters.

The scissor type electric elevator is a widely used high-altitude operation special equipment. Its scissor mechanical structure ensures high stability of the lifting platform wide working platform, and high bearing capacity, making the high-altitude operation range wider and suitable for multiple people to work simultaneously. It makes high-altitude operation more efficient and safer

After the electric elevator passes the inspection, the user unit shall organize the leasing unit,AfragolaElectric pull rod elevator, installation unit, and supervision unit to conduct acceptance. For the implementation of construction general contracting, the acceptance shall be organized by the construction general contracting unit. The acceptance form should be signed by the relevant responsible person.