HartwanCustomized electric elevatorThe market is still optimistic

announcer:hp935HP175192871 release time:2024-06-20 19:29:25

Hartwan200 kg electric elevator,

Setting requirements: The foundation and foundation of the construction electric elevator should meet the requirements of the user manual. Before installing the construction electric elevator, the foundation should be inspected and accepted according to the requirements of the specifications. Only after passing the inspection can the installation be carried out.

Every theater is a public place with a large number of people, and safety considerations should be taken into account in stage design. According to relevant national regulations, in order to prevent accidents caused by the crushing of electric elevators or improper control by drivers. Electric elevators should be equipped with the following necessary safety devices to ensure that the car of the electric elevator stops rising or falling in a timely manner.

Hartwan.Is the water cooling and air cooling of the hydraulic station the same?

Electric elevators used in various places.

.The bearing capacity of the building structure at the attachment point of the wall bracket should meet the requirements specified in the user manual for construction electric elevators.

In order to meet the needs of contemporary audiences and achieve perfect effects, in addition to lighting and sound, stage machinery is particularly important on the stage. On the stage, there are suspension rods, suspension points, lighting bridges, lighting suspension cages, and fire curtains. Under the stage, there are lifting platforms, car platforms, turntables, and lifting orchestras. Some lifting platforms are equipped with turntables, or there are lifting platforms in the turntables. Various types of lifting platforms are equipped in professional opera houses, dance theaters, drama theaters, and many internationally renowned music halls. It has the functions of quickly changing scenery, meeting the needs of stage craft layout, meeting the needs of stage design and choreographers creating special atmosphere and effects, the guide rail hydraulic lifting platform is superior in terms of product and changing the stage form according to the needs of the performance.

As a material loading and unloading equipment recognized by customers in the lifting platform, civil engineering, and operating costs. The editor of the electric elevator will provide a detailed analysis: the advantages of the product are that the equipment bears a large load, can achieve multiple points, and can be controlled up and down floors to achieve safe use.


HartwanCustomized electric elevatorThe market is still optimistic



Setting requirements: The guide rail should be rigid and flexible components such as wire ropes or chains should not be used.

In addition to fixed modes, there are also types of car mounted mobile devices. As the name suggests,HartwanElectric scissor type lifting platform, this type of lifting device is a combination of lifting equipment and car mounted systems. It is very flexible to move, and of course, it is better to use it. For example, there are such lifting devices in airports, as they can be moved, So the scope of the operation is not limited to a specific place, some advertisements are relatively high in height. At this time when installing outdoor advertisements, mobile lifting equipment can be used to transport billboards or staff to the designated height for work. This type of equipment can also be divided into two types based on the driving mode: hydraulic lifting and electric lifting. The so-called hydraulic lifting is the use of hydraulic oil to drive and reach a specified height. The electric mode is driven by a motor or teeth to lift to a certain height. However, currently, hydraulic lifting platforms are more widely used.

Small safe operation distance: Circuit voltage (kV) of external power lines<11~1035~110220330~550 Small safe operation distance (m) 4681015 Setting requirements: A small safe distance should be maintained between the outer edge of the construction electric elevator and the edge of the external overhead power line.

Where is it.Before installation, the installation unit should confirm that the foundation, foundation bearing capacity, and foundation drainage measures of the installed construction electric elevator and auxiliary heavy equipment comply with the requirements of the special construction plan for the installation and dismantling of the construction electric elevator based on the construction electric elevator foundation acceptance form, concealed engineering acceptance form, and concrete strength report.

Construction electric elevators should be equipped with cable guide frames and comply with regulatory requirements.

Stage equipment safety door. To prevent personnel from extending their heads, hands, and feet out of the shaft and objects from falling into the vertical shaft. Its vertical position should be closed, its cabin should be full of doors, and the height of the hoistway (hall door) should not be less than 8 meters; The electric door opening and closing switches should be removed from the vertical and passenger compartment doors. In order to prevent accidents caused by vertical, passenger car doors, and car roof doors not being closed.; Door interlocks should be installed on both the vertical and passenger compartment doors.


HartwanCustomized electric elevatorThe market is still optimistic



The L distance depends on the selected wall mount model.

High quality and low price.Civil engineering advantages: The pit depth of the guide rail type lifting platform is generally around 150-300mm, and the top layer is not affected. It can be customized according to the location and environment.

Check whether the sealing of components such as the oil cylinder, oil pipe,Hartwan1 ton electric elevator, and motor of the aluminum alloy electric elevator is good and whether there is any air leakage.

The counterweight guide rail should meet the specification requirements.

Hartwan.The angle between the wall bracket and the horizontal plane should comply with the requirements of the user manual.

Chain type electric lifting mechanism: With a good guiding mechanism, it can ensure that the equipment does not tilt during operation. Gear and rack electric lifting mechanism: precise transmission and high cost.

The landing door should be in a normally closed state. Without the permission of the construction electric elevator driver, the landing door shall not be opened.