GansuSmall electric automatic elevatorNeed to follow several principles

announcer:hp935HP175192871 release time:2024-05-07 13:40:17

Setting requirements: The installation and dismantling workers,GansuElectric elevator 200kg, and other operators of construction electric elevators should have special construction operations.

Setting requirements: The spacing of wall brackets along the vertical direction should comply with the provisions of the user manual.

Gansu.When using lifting equipment,GansuHand push electric elevator, the workbench should be kept in a horizontal state.

The oil cylinder and sealing components are made of imported components to solve the problem of unstable oil pressure and oil leakage of components for customers.

.Safety grounding device. In order to protect against electrical equipment. The metal casing of electrical equipment and the metal structure of electric elevators should be equipped with a safety grounding device. The grounding wire should operate multiple wires, and the neutral wire should not be arbitrarily held as a safety grounding wire. Its grounding resistance should not exceed 4 ohms; The power supply of the electric elevator can be cut off.

The safety distance between the outer edge of the upper part of the landing door and the moving parts of the electric elevator during normal operation should not be less than 0.75m; If the rated speed is not greater than 0.7m/s, when there is a major malfunction of the lifting platform, it should be repaired by professional personnel as soon as possible. After the malfunction occurs, it should not be used again to avoid accidents, personnel and property losses.


GansuSmall electric automatic elevatorNeed to follow several principles



The end height of the guide rail frame above the high attachment point should comply with the provisions of the user manual.

Installation position of upper limit switch: Under normal working conditions, the distance between the upper limit switch and the upper limit switch is 0.15m for SC type construction electric elevators, and 0.15m for SS type construction electric elevators (person)

Use floor doors and cage door devices on construction sites where conditions permit.

Energy costs.The angle between the wall bracket and the horizontal plane should comply with the requirements of the user manual.

Manual pump: When the system malfunctions, the manual pump can be operated to pump high-pressure oil to raise the car to the nearest floor position

It is reported that a fixed electric elevator has good lifting stability and can only be used for fixed operations, making high-altitude operations easier


GansuSmall electric automatic elevatorNeed to follow several principles



During normal operation, the horizontal distance between the closed cage door and the closed landing door should not exceed 150mm. Otherwise, measures should be taken to make it meet the requirements, or side protection devices at the entrance of the landing station that meet the requirements should be equipped. The distance between any opening between the side protection device and the hanging cage or landing door should not exceed 150mm.

Good quality.The pump body adopts an integrated pump station,GansuElectric cargo elevator, all equipped with imported high-quality pump stations, which can also be selected according to customer requirements to meet customer ideal requirements.

Precautions for safe use of electric elevators: Before use, remove any obstacles or debris near the electric elevator that may hinder operation, and check whether the operating handle can be used normally.

When the landing door is closed, the full width of the lifting passage opening should be covered.

Gansu.Small safe operation distance: Circuit voltage (kV) of external power lines<11~1035~110220330~550 Small safe operation distance (m) 4681015 Setting requirements: A small safe distance should be maintained between the outer edge of the construction electric elevator and the edge of the external overhead power line.

Construction electric elevators should be equipped with cable guide frames and comply with regulatory requirements.

The quality of the standard section should comply with the product manual and specification requirements.