CarlosaFixed electric elevatorAnytime

announcer:hp935HP175192871 release time:2024-05-03 14:36:02

Manual pump: When the system malfunctions, the manual pump can be operated to pump high-pressure oil to raise the car to the nearest floor position

From the above comparison, it can be seen that hydraulic electric lifting mechanisms have stable lifting, low noise, long service life, large load bearing capacity, and are relatively simple, making them suitable for use in stage equipment.

Carlosa.The noise of aluminum alloy electric elevators during operation is relatively low. If the noise is high, it is abnormal. Therefore,CarlosaFolding electric elevator, it is necessary to do a good job in troubleshooting, find the cause in a timely manner, reduce noise pollution, and reduce dangerous accidents

It is reported that a fixed electric elevator has good lifting stability and can only be used for fixed operations,CarlosaScissor fork electric lifting table, making high-altitude operations easier

.Setting requirements: The installation and dismantling workers, electricians, and other operators of construction electric elevators should have special construction operations.

It is reported that a fixed electric elevator has good lifting stability and can only be used for fixed operations making high-altitude operations easier

The quality of the standard section should comply with the product manual and specification requirements.


CarlosaFixed electric elevatorAnytime



Flat screw mechanical electric lifting mechanism: The lifting platform of this structure has the advantages of small civil engineering coordination, shallow foundation pit required, stable operation, low noise, accurate positioning, and low cost. Adopting a horizontal screw drive and a scissor fork structure to achieve the lifting motion of the table, it can be stopped arbitrarily within the range of travel.

Construction electric elevators must be equipped with lifting cages and reusable buffers, and comply with regulatory requirements.

Operating cost advantage and low failure rate: Due to the use of advanced hydraulic systems and good methods the operating failure rate can be reduced to a low level.

assets.Speed limiter. To prevent the driving speed from exceeding the normal speed. A speedometer should be installed (not required for floors below or including the second floor), which is an individual mechanism that is integrated with a safety clamp; The entrance and exit of the passenger compartment should be equipped with safety doors. Public places, family dormitories, and no deviation of one side is allowed. The lifting of goods does not allow people to stand on both sides of the platform the lifting platform platform platform that carries the load needs to be balanced, and the lifting of goods should try to maintain a stable and uniform speed.

The hydraulic oil forms a certain pressure by the vane pump, and enters the lower end of the hydraulic cylinder through an oil filter, explosion-proof electromagnetic directional valve,CarlosaElectric small hydraulic elevator, throttle valve, hydraulic control one-way valve, and balance valve, causing the hydraulic cylinder to move upwards and lift heavy objects. The return oil at the upper end of the hydraulic cylinder returns to the oil tank through the explosion-proof electromagnetic directional valve, and its rated pressure overflow valve is adjusted. The pressure gauge observes the reading value on the pressure gauge. The downward movement of the hydraulic cylinder (i.e. lowering of heavy objects).


CarlosaFixed electric elevatorAnytime



Every theater is a public place with a large number of people, and safety considerations should be taken into account in stage design. According to relevant national regulations, in order to prevent accidents caused by the crushing of electric elevators or improper control by drivers. Electric elevators should be equipped with the following necessary safety devices to ensure that the car of the electric elevator stops rising or falling in a timely manner.

Inspection requirements.During the use period, the user unit should organize professional technical personnel to inspect the construction electric elevator monthly according to the standard requirements, and record the inspection results.

Platform.

When the distance between the outer edge of the construction electric elevator and the edge line of the external overhead power line cannot meet the requirements in the table above, the handover system should be implemented, and drivers should fill out the handover record form according to the standard requirements. The driver should conduct a pre shift inspection and confirm that there are no errors before starting the machine for operation.

Setting requirements: The quality of the standard section should meet the requirements of the product manual. Before installing the construction electric elevator, all components should be inspected, and standard sections and other components with severe wear and deformation should be replaced.

Setting requirements: Drainage measures should be set up for the foundation of construction electric elevators to ensure smooth drainage.