Hague10 meter electric lifting platformCommon sense of tool use

announcer:hp935HP175192871 release time:2024-04-21 10:22:02

Setting requirements: The foundation and foundation of the construction electric elevator should meet the requirements of the user manual. Before installing the construction electric elevator, the foundation should be inspected and accepted according to the requirements of the specifications. Only after passing the inspection can the installation be carried out.

The entrance of each landing platform must be equipped with a landing door, which must open towards the landing platform side, and the door bolt must be set on the side next to the construction electric elevator.

Hague.The shutdown device (emergency stop switch) should be non automatic reset type.

After the electric elevator passes the inspection, the user unit shall organize the leasing unit,HagueElectric mobile hydraulic elevator, and supervision unit to conduct acceptance. For the implementation of construction general contracting, the acceptance shall be organized by the construction general contracting unit. The acceptance form should be signed by the relevant responsible person.

.Double layer steel mesh: The diameter of the steel bars is 12mm, with a spacing of 200mm.

It is reported that a fixed electric elevator has good lifting stability and can only be used for fixed operations, making high-altitude operations easier

Use floor doors and cage door devices on construction sites where conditions permit.


Hague10 meter electric lifting platformCommon sense of tool use



Drainage measures need to be considered around the foundation. (Drain the accumulated water on the foundation).

How to determine the sufficient amount of clean oil for the hydraulic station of an electric elevator? Why cannot water be used to flush the hydraulic station of an electric elevator?

Before installation, the installation unit should confirm that the foundation, foundation bearing capacity, embedded parts,Hague12 meter electric elevator, and foundation drainage measures of the installed construction electric elevator and auxiliary heavy equipment comply with the requirements of the special construction plan for the installation and dismantling of the construction electric elevator based on the construction electric elevator foundation acceptance form, concealed engineering acceptance form, and concrete strength report.

Encyclopedic knowledge.Before operating the construction electric elevator, routine inspections should be carried out according to regulations and inspection records should be filled out.

The landing door should meet the requirements of the specifications and achieve standardization.

The motor of the hydraulic guide rail lifting platform is set around the wellbore,HagueIndoor electric elevator, occupying a relatively small area, improving the utilization rate of the wellbore area.


Hague10 meter electric lifting platformCommon sense of tool use



As a material loading and unloading equipment recognized by customers in the lifting platform, the guide rail hydraulic lifting platform is superior in terms of product, and operating costs. The editor of the electric elevator will provide a detailed analysis: the advantages of the product are that the equipment bears a large load, can achieve multiple points, and can be controlled up and down floors to achieve safe use.

safety requirements .Small safe operation distance: Circuit voltage (kV) of external power lines<11~1035~110220330~550 Small safe operation distance (m) 4681015 Setting requirements: A small safe distance should be maintained between the outer edge of the construction electric elevator and the edge of the external overhead power line.

Normal operation starts. Click on this free download of construction technical information. Safety limit devices should be installed on electric elevators for construction with upper and lower limit switches that are sensitive and reliable.

The L distance depends on the selected wall mount model.

Hague.In addition to ground protective fences, low level doors can be used. Low level doors should meet the following requirements: the height of the door should be between 1m and 2m. And there should be at least protective railings, a half height middle crossbar, and a toe board at least 150mm above the ground.

The safety notice board for construction electric elevators should be prominently placed on the hanging cage for the rated load capacity and rated number of passengers of the construction electric elevator. It is strictly prohibited to use construction electric elevators beyond the rated load capacity or rated number of passengers.

The scissor type electric elevator is a widely used high-altitude operation special equipment. Its scissor mechanical structure ensures high stability of the lifting platform wide working platform, and high bearing capacity, making the high-altitude operation range wider and suitable for multiple people to work simultaneously. It makes high-altitude operation more efficient and safer