PotsdamElectric mobile hydraulic elevatorHow to play a practical role

announcer:hp935HP175192871 release time:2024-04-20 14:06:15

The entrance of each landing platform must be equipped with a landing door, which must open towards the landing platform side,PotsdamSmall electric elevator, and the door bolt must be set on the side next to the construction electric elevator.

Steel wire ropes, pulleys, and counterweight steel wire ropes shall comply with the following regulations: the characteristics of steel wire ropes shall comply with the requirements of General Purpose Steel Wire Ropes GB/T20118; Maintenance, wear deformation, and corrosion of steel wire ropes

Potsdam.The movement of its related components is direct.

Construction electric elevators should be equipped with cable guide frames and comply with regulatory requirements.

.Protective measures should comply with regulatory requirements.

Setting requirements: For construction electric elevators that operate in multiple shifts, the handover system should be implemented, and drivers should fill out the handover record form according to the standard requirements. The driver should conduct a pre shift inspection and confirm that there are no errors before starting the machine for operation.

Drivers of construction electric elevators should hold special construction operations and are not allowed to operate without a certificate.


PotsdamElectric mobile hydraulic elevatorHow to play a practical role



The foundation production and acceptance of electric elevators for foundation construction should comply with the user manual and regulatory requirements.

The cargo is 0.5m.

Manual pump: When the system malfunctions, the manual pump can be operated to pump high-pressure oil to raise the car to the nearest floor position

Total quality assurance.The entrance of each landing platform must be equipped with a landing door, which must open towards the landing platform side, and the door bolt must be set on the side next to the construction electric elevator.

In order to meet the needs of contemporary audiences and achieve perfect effects, in addition to lighting and sound, there are suspension rods, suspension points, lighting bridges, and fire curtains. Under the stage,PotsdamElectric hydraulic elevator,PotsdamAutomatic elevator electric small, there are lifting platforms, car platforms, turntables, and lifting orchestras. Some lifting platforms are equipped with turntables, or there are lifting platforms in the turntables. Various types of lifting platforms are equipped in professional opera houses, dance theaters, drama theaters, and many internationally renowned music halls. It has the functions of quickly changing scenery, meeting the needs of stage craft layout, meeting the needs of stage design and choreographers, creating special atmosphere and effects and changing the stage form according to the needs of the performance.

Setting requirements: The wall bracket should use the manufacturer's matching standard products.


PotsdamElectric mobile hydraulic elevatorHow to play a practical role



Mechanical devices controlled by cage movement should not be used to open or close the landing door.

Inspection environment.The foundation production and acceptance of electric elevators for foundation construction should comply with the user manual and regulatory requirements.

Construction electric elevators should be equipped with upper limit switches that are sensitive and reliable.

When a rigid 5000mm2 square or circular flat surface is applied with a normal force of 600N to either side of the door, the door may not meet the above requirements, but safety should be maintained.

Potsdam.During normal operation, the horizontal distance between the closed cage door and the closed landing door should not exceed 150mm. Otherwise, measures should be taken to make it meet the requirements, or side protection devices at the entrance of the landing station that meet the requirements should be equipped. The distance between any opening between the side protection device and the hanging cage or landing door should not exceed 150mm.

The angle between the wall bracket and the horizontal plane should comply with the requirements of the user manual.

Use floor doors and cage door devices on construction sites where conditions permit.