Busgow FreiburgElectric mobile hydraulic elevatorDoes it have any effect on practicality?

announcer:hp935HP175192871 release time:2024-04-18 11:05:46

The foundation base or embedded parts should be fully embedded in the concrete foundation plate.

Before operating the construction electric elevator,Busgow FreiburgSmall electric elevator platform, routine inspections should be carried out according to regulations and inspection records should be filled out.

Busgow Freiburg.Do not move after lifting, and do not lift until the four legs are firmly supported.

The scaffolding of the parking platform should be laid tightly and firmly.

.Stage equipment safety door. To prevent personnel from extending their heads, hands, and feet out of the shaft and objects from falling into the vertical shaft. Its vertical position should be closed, its cabin should be full of doors, and the height of the hoistway (hall door) should not be less than 8 meters; The electric door opening and closing switches should be removed from the vertical and passenger compartment doors. In order to prevent accidents caused by vertical,Busgow FreiburgElevator scissor electric, passenger car doors, and car roof doors not being closed.; Door interlocks should be installed on both the vertical and passenger compartment doors.

The foundation base or embedded parts should be fully embedded in the concrete foundation plate.

Later, when there is a major malfunction of the lifting platform, it should be repaired by professional personnel as soon as possible. After the malfunction occurs, it should not be used again to avoid accidents, personnel and property losses.


Busgow FreiburgElectric mobile hydraulic elevatorDoes it have any effect on practicality?



The hydraulic oil forms a certain pressure by the vane pump, and enters the lower end of the hydraulic cylinder through an oil filter, explosion-proof electromagnetic directional valve, hydraulic control one-way valve, and balance valve, causing the hydraulic cylinder to move upwards and lift heavy objects. The return oil at the upper end of the hydraulic cylinder returns to the oil tank through the explosion-proof electromagnetic directional valve, and its rated pressure overflow valve is adjusted. The pressure gauge observes the reading value on the pressure gauge. The downward movement of the hydraulic cylinder (i.e. lowering of heavy objects).

Before use, we should observe whether there is any damage to the electric elevator. We can conduct a no-load test to raise and lower it. If there are any damaged parts they should be replaced in a timely manner to prevent major accidents.

After the electric elevator passes the inspection, the user unit shall organize the leasing unit installation unit, and supervision unit to conduct acceptance. For the implementation of construction general contracting, the acceptance shall be organized by the construction general contracting unit. The acceptance form should be signed by the relevant responsible person.

The cheapest.The quality of the standard section should comply with the product manual and specification requirements.

Low power consumption: When the hydraulic guide rail lifting platform descends, it is driven by the pressure generated by its own weight, greatly saving energy and reducing consumption.

The foundation production and acceptance of electric elevators for foundation construction should comply with the user manual and regulatory requirements.


Busgow FreiburgElectric mobile hydraulic elevatorDoes it have any effect on practicality?



Safety performance: Electric elevators not only have the safety device of traditional traction elevators, but also have an overflow valve to prevent excessive system pressure during upward movement

Quality department.During loading and unloading, the horizontal distance between the edge of the cage door and the edge of the landing station should not exceed 50mm.

The impact load can cause early wear, fracture, and fragmentation of mechanical structural components, as well as generate impact pressure in the hydraulic system, which in turn can damage hydraulic components, oil seals, and high-pressure oil

Construction electric elevators outside the lightning protection range

Busgow Freiburg.A complete lifting platform accessory can be selected and customized according to different places, venues, and environmental usage conditions. Meet the needs of different users. So why lifting platforms can be used and installed in so many industries and places is because they can achieve multi-purpose,Busgow FreiburgElevator manufacturer's electric elevator, demonstrate multifunctional, meet various different needs, and win market demand. In modern industrial transportation processes lifting platforms have begun to play an increasingly important role, whether in airports, docks, warehouses, floors, they have played a very practical value, It has also brought great contributions to the entire industry and even the entire economic development. However, long-term operation and use of these devices inevitably lead to wear and consumption, and regular maintenance and upkeep are essential. Otherwise, both work efficiency and utilization rate will decrease, the gains and losses will outweigh the losses.

In addition to ground protective fences, low level doors can be used. Low level doors should meet the following requirements: the height of the door should be between 1m and 2m. And there should be at least protective railings, a half height middle crossbar, and a toe board at least 150mm above the ground.

Small safe operation distance: Circuit voltage (kV) of external power lines<11~1035~110220330~550 Small safe operation distance (m) 4681015 Setting requirements: A small safe distance should be maintained between the outer edge of the construction electric elevator and the edge of the external overhead power line.