VeronaScissor fork electric lifting tableOverview of the style differences

announcer:hp935HP175192871 release time:2024-03-29 11:35:41

Use floor doors and cage door devices on construction sites where conditions permit.

When the horizontal distance between the edge of the cage and the edge of the landing or between the cage and the landing door is greater than 150mm and there is no effective protection from other structures, the side protection device for the landing entrance should be equipped.

Verona..

From the perspective of the safety performance of the machinery itself,VeronaThree meter electric elevator, mechanical components may fall off or be damaged due to various factors. This problem depends on regular inspection and maintenance of the machinery

.Work is essential, and the main protective accessories include safety belts, guardrails, protective covers, platforms and stairs, etc.

To ensure safe and reliable braking of the lifting platform and prevent accidents, a hydraulic control one-way valve, also known as a hydraulic lock, is added to ensure safe self-locking in the event of an accidental rupture of the hydraulic pipeline. An overload sound control alarm has been installed to distinguish between overload or equipment failure. Electrical system explosion-proof button SB1&flash; The rotation of the SB6 motor and the commutation of the explosion-proof electromagnetic directional valve are used to maintain load increase or decrease, and; Program adjustment time delay to avoid frequent movement of electric elevators that may affect their service life.

During loading and unloading, the horizontal distance between the edge of the cage door and the edge of the landing station should not exceed 50mm.


VeronaScissor fork electric lifting tableOverview of the style differences



Secondly, for the replacement of hydraulic oil on the lifting platform, it is recommended to replace it every three months. If the frequency of use is not high, it can be replaced once a year. The hydraulic oil must be clean, and after changing the hydraulic oil, it must be automatically lifted and lowered 2 to 3 times to ensure that the air in the oil cylinder is completely discharged, maintain sufficient space,VeronaElectric 6-meter elevator, and ensure that the lifting platform can be lifted to the rated lifting height.

Items and other miscellaneous items.

Construction electric elevators outside the lightning protection range

Application process.The landing door should meet the requirements of the specifications and achieve standardization.

Setting requirements: The guide rail should be rigid and flexible components such as wire ropes or chains should not be used.

Safety grounding device. In order to protect against electrical equipment. The metal casing of electrical equipment and the metal structure of electric elevators should be equipped with a safety grounding device. The grounding wire should operate multiple wires, and the neutral wire should not be arbitrarily held as a safety grounding wire. Its grounding resistance should not exceed 4 ohms; The power supply of the electric elevator can be cut off.


VeronaScissor fork electric lifting tableOverview of the style differences



Construction electric elevators should be equipped with cable guide frames and comply with regulatory requirements.

Bidding.Steel wire ropes, and counterweight steel wire ropes shall comply with the following regulations: the characteristics of steel wire ropes shall comply with the requirements of General Purpose Steel Wire Ropes GB/T20118; Maintenance, wear, deformation, and corrosion of steel wire ropes

Only after the operation of professional personnel can the suspension cage movement be restored.

Secondly, the lifting platform is driven by electrical energy and lifted by the hydraulic system. During operation it is necessary to avoid irregular operations. To ensure the normal and orderly operation of the lifting platform and achieve the ideal unloading level, timely inspection of various functions is essential.

Verona.The connection method and angle between the wall bracket and the building structure should comply with the requirements of the user manual.

Once again, whether the sealing rings are damaged or ineffective, whether there is a lack of hydraulic oil,VeronaElectric belt elevator, and whether the oil cylinder is leaking. It is necessary to clean the lifting frame, scissors, wiring, and oil cylinder once a week to avoid dust and debris affecting normal operation.

Stage equipment safety door. To prevent personnel from extending their heads hands, and feet out of the shaft and objects from falling into the vertical shaft. Its vertical position should be closed, its cabin should be full of doors, and the height of the hoistway (hall door) should not be less than 8 meters; The electric door opening and closing switches should be removed from the vertical and passenger compartment doors. In order to prevent accidents caused by vertical, passenger car doors, and car roof doors not being closed.; Door interlocks should be installed on both the vertical and passenger compartment doors.