New South Memphis500kg electric elevatorWhat causes abnormal machining accuracy failure

announcer:hp935HP175192871 release time:2024-03-26 12:31:24

Low power consumption: When the hydraulic guide rail lifting platform descends, it is driven by the pressure generated by its own weight, greatly saving energy and reducing consumption.

Setting requirements: The quality of the standard section should meet the requirements of the product manual. Before installing the construction electric elevator, all components should be inspected, and standard sections and other components with severe wear and deformation should be replaced.

New South Memphis.The magnetic directional valve returns to the fuel tank. To ensure stable landing of heavy objects and safe and reliable braking, a balance valve is installed on the return oil circuit to balance the circuit and maintain pressure, so that the landing speed does not change due to heavy objects. It is adjusted by the saving valve

Drainage measures need to be considered around the foundation. (Drain the accumulated water on the foundation).

.When applying a normal force of 300N to any position on either side of the door using a rigid 5000mm2 square or circular flat surface in the locked position of the landing door, the door should be able to withstand and have no deformation; - Deformation not exceeding 30mm; After the test, it worked normally.

Horizontal lead screw mechanical electricity

Human improper operation is the main factor causing malfunctions in scissor type electric elevators. When stacking goods,New South MemphisUsed electric elevator platform, electric elevators should stack the goods neatly, which is better than stacking them in the center of the cargo stacking area of the cargo elevator to avoid imbalance between the two ends of the stacking area. Eventually, during the operation of the electric elevator, it may cause the electric elevator to lose balance. After the goods are stacked completely, ropes should be used to lock the goods, so that they are not afraid of the goods during the lifting process; Careless; Scattered down


New South Memphis500kg electric elevatorWhat causes abnormal machining accuracy failure



For customers to use and operate the lifting platform for a long time, the editor briefly introduces how to maintain and repair the lifting platform: First of all, normal maintenance is mainly focused on prevention, especially if any damage or malfunction is detected and corrected or repaired in a timely manner. Careful inspection and maintenance at this time can save costs and avoid larger problems,New South MemphisElectric small hydraulic elevator, including installation, disassembly, and before resetting after action. Fall arrest safety gear

Then, the lifting platform platform platform that carries the load needs to be balanced, and no deviation of one side is allowed. The lifting of goods does not allow people to stand on both sides of the platform, and the difference between the net width and the outlet width of the cage door should not exceed 120mm. When the floor door is closed, except for the gap between the lower part of the door that should not exceed 35mm, the size of any through-hole and opening related to the distance between any door and adjacent moving parts, as well as the gap around the door or between parts, should comply with the provisions of Table 4 of 'Mechanical Safety - Safety Distance to Prevent Upper and Lower Limbs from Touching Dangerous Areas' GB23821-2009.

Setting requirements: The main connection methods between the wall bracket and the building include: connecting the wall bracket with the embedded parts on the wall; Fix with wall bolts; Embedded bolts; Welding with steel structures.

Horizontal lead screw mechanical electricity


New South Memphis500kg electric elevatorWhat causes abnormal machining accuracy failure



Acceptance: Concrete strength grade C30, strength testing report.

resources.Construction electric elevators should be equipped with cable guide frames and comply with regulatory requirements.

Steel wire rope construction electric elevators and reusable steel wire ropes should be equipped with anti loosening rope devices,New South MemphisNiuli brand electric elevator, which should have compliant loosening rope switches and be able to interrupt any movement of the lifting cage until it is approved by a professional

Electric elevators used in various places.

New South Memphis.The wall bracket of the construction electric elevator should be intact and reliably fixed and its attachment distance, wall bracket spacing, and end height must comply with the requirements of the 'User Manual'. The angle between the plane of the wall bracket and the normal direction of the attachment surface should not exceed 8 degrees;. When the attachment device does not meet the requirements of the 'User Manual' due to conditions, its calculation sheet, and production materials should be confirmed by the manufacturer or reviewed by the technical leader of the installation unit, and verified by experts.

In addition to ground protective fences low level doors can be used. Low level doors should meet the following requirements: the height of the door should be between 1m and 2m. And there should be at least protective railings, a half height middle crossbar, and a toe board at least 150mm above the ground.

Before operating the construction electric elevator, routine inspections should be carried out according to regulations and inspection records should be filled out.