Xinhua6m electric elevatorWhat are the performance

announcer:hp935HP175192871 release time:2024-03-23 13:56:22

When the landing door is closed,XinhuaLight electric elevator, the full width of the lifting passage opening should be covered.

Emergency manual valve: In case of power failure, it can cause the car to descend to the nearest floor position and open the door

Xinhua.Correct use can also greatly improve work efficiency. So how should it be used?

During normal operation, the horizontal distance between the closed cage door and the closed landing door should not exceed 150mm. Otherwise,XinhuaSmall electric elevator, measures should be taken to make it meet the requirements, or side protection devices at the entrance of the landing station that meet the requirements should be equipped. The distance between any opening between the side protection device and the hanging cage or landing door should not exceed 150mm.

.Work is essential, and the main protective accessories include safety belts, protective covers, platforms and stairs, etc.

The landing door should meet the requirements of the specifications and achieve standardization.

Especially suitable for steel structured factories suitable for both indoor and outdoor installation.


Xinhua6m electric elevatorWhat are the performance



Setting requirements: The installation and dismantling workers, electricians and other operators of construction electric elevators should have special construction operations.

Normal operation starts. Click on this free download of construction technical information. Safety limit devices should be installed on electric elevators for construction, with upper and lower limit switches that are sensitive and reliable.

The end height of the guide rail frame above the high attachment point should comply with the provisions of the user manual.

Latest consultation.The distance between the electric hoist and overhead line in Electrical safety construction shall meet the specification requirements, otherwise protective measures shall be taken.

Setting requirements: The anti loosening and anti loosening parts between the connecting parts should comply with the provisions of the user manual and should not be replaced by other objects. For connecting bolts with pre tightening requirements, a torque wrench or special tool should be used to accurately tighten the bolts to the specified torque value according to the specified tightening sequence. When installing standard section connecting bolts, it is advisable to place the screw at the bottom and the nut at the top.

Before installation, the installation unit should confirm that the foundation, foundation bearing capacity, embedded parts, and foundation drainage measures of the installed construction electric elevator and auxiliary heavy equipment comply with the requirements of the special construction plan for the installation and dismantling of the construction electric elevator based on the construction electric elevator foundation acceptance form, concealed engineering acceptance form and concrete strength report.


Xinhua6m electric elevatorWhat are the performance



Protective measures should comply with regulatory requirements.

Inspection requirements.Monthly maintenance and inspection of hydraulic lifting platform rollers, intermediate shafts and bearings, oil cylinder pin shafts and bearings, and at this position, the hydraulic ground should be 40-50 millimeters higher than the bottom of the box. If the hydraulic oil becomes dark,XinhuaMigao Electric Elevator, sticky, or has foreign objects such as gravel, it should be replaced in a timely manner (32 # hydraulic oil). Annual maintenance and inspection of all hydraulic pipelines and joints of the lifting platform. The pipeline must not be damaged, and the joints must not be loose. All joints must be tightened. Remove and disassemble the lowering valve of the lifting platform, blow out the plunger with compressed air, then install it and reinstall it. Drain and discard the hydraulic oil, tighten the joint, remove the oil filter, clean it with compressed air, and then return it to the oil tank and connect the pipeline.

Non automatic reset upper and lower limit switches should be installed at both the upper and lower ends of the stroke, which should be able to cut off the power supply before the suspension cage and other mechanical stop devices (such as buffers),

The landing door should meet the requirements of the specifications and achieve standardization.

Xinhua.Steel wire ropes, pulleys, and counterweight steel wire ropes shall comply with the following regulations: the characteristics of steel wire ropes shall comply with the requirements of General Purpose Steel Wire Ropes GB/T20118; Maintenance, wear, deformation, the guide rail hydraulic lifting platform is superior in terms of product, civil engineering, and operating costs. The editor of the electric elevator will provide a detailed analysis: the advantages of the product are that the equipment bears a large load, can achieve multiple points, and can be controlled up and down floors to achieve safe use.

Low power consumption: When the hydraulic guide rail lifting platform descends, it is driven by the pressure generated by its own weight, greatly saving energy and reducing consumption.