LiaoningElectric water gate elevatorWhat is the defect processing method

announcer:hp935HP175192871 release time:2024-03-22 13:15:19

Implementing multiple shifts of homework should fill in and submit records according to regulations.

Setting requirements: The guide rail should be rigid and flexible components such as wire ropes or chains should not be used.

Liaoning.The safety overtravel of limit switches and upper limit switches should comply with regulatory requirements.

Electric elevators used in various places.

.Chain type electric lifting mechanism: With a good guiding mechanism, it can ensure that the equipment does not tilt during operation. Gear and rack electric lifting mechanism: precise transmission and high cost.

The end height of the guide rail frame above the high attachment point should comply with the provisions of the user manual.

Chain type electric lifting mechanism: With a good guiding mechanism,LiaoningAutomatic electric elevator, it can ensure that the equipment does not tilt during operation. Gear and rack electric lifting mechanism: precise transmission and high cost.


LiaoningElectric water gate elevatorWhat is the defect processing method



Secondly, for the replacement of hydraulic oil on the lifting platform, it is recommended to replace it every three months. If the frequency of use is not high, and after changing the hydraulic oil, it must be automatically lifted and lowered 2 to 3 times to ensure that the air in the oil cylinder is completely discharged, maintain sufficient space, and ensure that the lifting platform can be lifted to the rated lifting height.

How to determine the sufficient amount of clean oil for the hydraulic station of an electric elevator? Why cannot water be used to flush the hydraulic station of an electric elevator?

The connection method and angle between the wall bracket and the building structure should comply with the requirements of the user manual.

Test conclusion.After the electric elevator passes the inspection, the user unit shall organize the leasing unit, installation unit, and supervision unit to conduct acceptance. For the implementation of construction general contracting, the driver of the construction electric elevator should inspect the construction electric elevator according to the requirements of the user manual and specifications, record the inspection results, and report any problems found to the user unit.

Setting requirements: The installation and dismantling workers, electricians, and other operators of construction electric elevators should have special construction operations.


LiaoningElectric water gate elevatorWhat is the defect processing method



Setting requirements: The spacing of wall brackets along the vertical direction should comply with the provisions of the user manual.

Direct labor.In order to meet the needs of contemporary audiences and achieve perfect effects, stage machinery is particularly important on the stage. On the stage, there are suspension rods, suspension points, lighting bridges, lighting suspension cages and fire curtains. Under the stage, car platforms there are lifting platforms, turntables, and lifting orchestras. Some lifting platforms are equipped with turntables, or there are lifting platforms in the turntables. Various types of lifting platforms are equipped in professional opera houses, dance theaters, drama theaters, and many internationally renowned music halls. It has the functions of quickly changing scenery meeting the needs of stage craft layout, meeting the needs of stage design and choreographers, creating special atmosphere and effects, and changing the stage form according to the needs of the performance.

Mobile electric elevators are divided into: four wheel mobile lifting platform, two wheel traction lifting platform, car modified lifting platform, manual lifting platform, manual lifting platform, and AC/DC dual purpose lifting platform

The hydraulic oil forms a certain pressure by the vane pump, and enters the lower end of the hydraulic cylinder through an oil filter, explosion-proof electromagnetic directional valve,LiaoningMobile small electric elevator, throttle valve, hydraulic control one-way valve, and balance valve, causing the hydraulic cylinder to move upwards and lift heavy objects. The return oil at the upper end of the hydraulic cylinder returns to the oil tank through the explosion-proof electromagnetic directional valve, and its rated pressure overflow valve is adjusted. The pressure gauge observes the reading value on the pressure gauge. The downward movement of the hydraulic cylinder (i.e. lowering of heavy objects).

Liaoning.The setting of the cable guide frame should comply with the user manual and regulatory requirements.

Low level doors should be equipped with interlocking devices that can verify their closed and locked positions. The action of this interlocking device should be at the entrance of the cage. Simple use should not interfere with the operation of the interlocking device. The attached wall bracket should use matching standard products. When the wall bracket cannot meet the requirements of the construction site, it should be designed separately. The design of the wall bracket should meet the requirements of component stiffness, strength, stability, etc., and the production should meet the design requirements.

Electric elevators used in various places.