Xilingol LeagueGuide rail electric elevatorContinuous upgrading of production technology

announcer:hp935HP175192871 release time:2024-03-22 13:00:17

To ensure safe and reliable braking of the lifting platform and prevent accidents, a hydraulic control one-way valve, also known as a hydraulic lock is added to ensure safe self-locking in the event of an accidental rupture of the hydraulic pipeline. An overload sound control alarm has been installed to distinguish between overload or equipment failure. Electrical system explosion-proof button SB1&flash; The rotation of the SB6 motor and the commutation of the explosion-proof electromagnetic directional valve are used to maintain load increase or decrease, and; Program adjustment time delay to avoid frequent movement of electric elevators that may affect their service life.

Setting requirements: The main connection methods between the wall bracket and the building include: connecting the wall bracket with the embedded parts on the wall; Fix with wall bolts; Embedded bolts; Welding with steel structures.

Xilingol League.Fully autonomous lifting is widely used in various high-altitude work fields, such as factory maintenance, airport maintenance, street light maintenance, and so on; How to use electric elevators correctly to extend the service life of the equipment and be flexible

When a rigid 5000mm2 square or circular flat surface is applied with a normal force of 600N to either side of the door,Xilingol LeagueElectric tatami elevator, the door may not meet the above requirements, but safety should be maintained.

.The hydraulic oil forms a certain pressure by the vane pump, and enters the lower end of the hydraulic cylinder through an oil filter, throttle valve, hydraulic control one-way valve, and balance valve,Xilingol LeagueSmall electric mobile elevator, causing the hydraulic cylinder to move upwards and lift heavy objects. The return oil at the upper end of the hydraulic cylinder returns to the oil tank through the explosion-proof electromagnetic directional valve, and its rated pressure overflow valve is adjusted. The pressure gauge observes the reading value on the pressure gauge. The downward movement of the hydraulic cylinder (i.e. lowering of heavy objects).

Drainage measures need to be considered around the foundation. (Drain the accumulated water on the foundation).

Chain type electric lifting mechanism: With a good guiding mechanism, it can ensure that the equipment does not tilt during operation. Gear and rack electric lifting mechanism: precise transmission and high cost.


Xilingol LeagueGuide rail electric elevatorContinuous upgrading of production technology



Before operating the construction electric elevator, routine inspections should be carried out according to regulations and inspection records should be filled out.

Setting requirements: Buffers should be installed below the suspension cage and counterweight running channel.

Setting requirements: The verticality deviation of the installation of the guide rail frame of the construction electric elevator should comply with the requirements of the user manual and specifications, as specified in the above table.

Latest consultation.Construction electric elevators should be equipped with cable guide frames and comply with regulatory requirements.

Secondly, the lifting platform is driven by electrical energy and lifted by the hydraulic system. During operation, timely inspection of various functions is essential.

Drainage measures need to be considered around the foundation. (Drain the accumulated water on the foundation).


Xilingol LeagueGuide rail electric elevatorContinuous upgrading of production technology



Later, when there is a major malfunction of the lifting platform, it should be repaired by professional personnel as soon as possible. After the malfunction occurs, it should not be used again to avoid accidents, personnel and property losses.

Honest service.The list of materials for making landing doors is as follows: Table 1: List of materials for making landing doors. Landing doors should be installed at the entrance of each landing station,Xilingol LeagueElectric elevator mechanism, and the landing doors should function properly.

There is a certain itinerary.

During the use period, the user unit should organize professional technical personnel to inspect the construction electric elevator monthly according to the standard requirements, and record the inspection results.

Xilingol League.Setting requirements: For construction electric elevators with foundations installed on roof slabs, floors or other lower suspended structures, the bearing capacity of the foundation support structure should be checked. Click here to download the construction technical information for free. Basic drainage facilities should be installed.

Stage equipment safety door. To prevent personnel from extending their heads, hands, and feet out of the shaft and objects from falling into the vertical shaft. Its vertical position should be closed, its cabin should be full of doors, and the height of the hoistway (hall door) should not be less than 8 meters; The electric door opening and closing switches should be removed from the vertical and passenger compartment doors. In order to prevent accidents caused by vertical, passenger car doors, and car roof doors not being closed.; Door interlocks should be installed on both the vertical and passenger compartment doors.

The angle between the wall bracket and the horizontal plane should comply with the requirements of the user manual.