The entrance of each landing platform must be equipped with a landing door, which must open towards the landing platform side, and the door bolt must be set on the side next to the construction electric elevator.

Setting requirements: For construction electric elevators with foundations installed on roof slabs, floors, or other lower suspended structures, the bearing capacity of the foundation support structure should be checked. Click here to download the construction technical information for free. Basic drainage facilities should be installed.

Montpellier.Savings, rate of increase and decrease. To ensure safe and reliable braking and prevent accidents, a hydraulic control one-way valve, also known as a hydraulic lock, it will take on the function of raising or lowering. In order to prevent the lift car from crashing or sinking, stage equipment should be dismantled with over travel switches that can cut off power and cannot be automatically reset, and installed in the machine room, rather than in the shaft; A buffer should be installed that can absorb the energy of the moving mechanism and reduce impact.

.For customers to use and operate the lifting platform for a long time, the editor briefly introduces how to maintain and repair the lifting platform: First of all,MontpellierPortable electric elevator, normal maintenance is mainly focused on prevention, especially if any damage or malfunction is detected and corrected or repaired in a timely manner. Careful inspection and maintenance at this time can save costs and avoid larger problems resulting in costly repairs.

Pipeline rupture valve: When the hydraulic system pipeline ruptures and the car stalls and descends, it can automatically cut off the oil circuit and stop descent

Setting requirements: Before starting work every day and changing shifts, the driver of the construction electric elevator should inspect the construction electric elevator according to the requirements of the user manual and specifications, record the inspection results and report any problems found to the user unit.


MontpellierElectric mini elevatorThere are several levels of processing



The spacing between wall brackets and the height of guide rails above the high attachment point should comply with the requirements of the user manual.

Lower limit switch: In normal working state, before the suspension cage touches the buffer,MontpellierAll electric small elevator, the lower limit switch first acts.

The connection method and angle between the wall bracket and the building structure should comply with the requirements of the user manual.

new product.Setting requirements: Each landing entrance should be equipped with a landing door, which should cover the opening with its full width, and should not open towards the lifting passage.

Before operating the construction electric elevator, routine inspections should be carried out according to regulations and inspection records should be filled out.

Setting requirements: Each landing entrance should be equipped with a landing door, which should cover the opening with its full width, strength testing report.

new product.The list of materials for making landing doors is as follows: Table 1: List of materials for making landing doors. Landing doors should be installed at the entrance of each landing station, and the landing doors should function properly.

The counterweight steel wire rope should be equipped with an anti loosening device that is sensitive and reliable.

Mechanical devices controlled by cage movement should not be used to open or close the landing door.

Montpellier.Secondly, the lifting platform is driven by electrical energy and lifted by the hydraulic system. During operation,MontpellierHand propelled electric elevator, it is necessary to avoid irregular operations. To ensure the normal and orderly operation of the lifting platform and achieve the ideal unloading level, timely inspection of various functions is essential.

Acceptance: Concrete strength grade C30, strength testing report.

In addition to ground protective fences, low level doors can be used. Low level doors should meet the following requirements: the height of the door should be between 1m and 2m. And there should be at least protective railings, a half height middle crossbar, and a toe board at least 150mm above the ground.