ZhongshanFully automatic electric elevatorDevelopment is inevitable

announcer:hp935HP175192871 release time:2024-02-06 09:05:34

Setting requirements: Drainage measures should be set up for the foundation of construction electric elevators to ensure smooth drainage.

Monthly maintenance and inspection of hydraulic lifting platform rollers, intermediate shafts and bearings oil cylinder pin shafts and bearings, boom hinge shafts and bearings for wear. Add some oil to each part to extend the service life of the lifting platform bearings. The quality and level of hydraulic oil. The lifting platform should be raised throughout the entire process, and at this position, the hydraulic ground should be 40-50 millimeters higher than the bottom of the box. If the hydraulic oil becomes dark, sticky, or has foreign objects such as gravel, it should be replaced in a timely manner (32 # hydraulic oil). Annual maintenance and inspection of all hydraulic pipelines and joints of the lifting platform. The pipeline must not be damaged, and the joints must not be loose. All joints must be tightened. Remove and disassemble the lowering valve of the lifting platform, blow out the plunger with compressed air, then install it and reinstall it. Drain and discard the hydraulic oil,Zhongshan2 meter micro electric lifting platform, tighten the joint, remove the oil filter, clean it with compressed air, and then return it to the oil tank and connect the pipeline.

Zhongshan.The magnetic directional valve returns to the fuel tank. To ensure stable landing of heavy objects and safe and reliable braking, a balance valve is installed on the return oil circuit to balance the circuit and maintain pressure,ZhongshanElectric hydraulic elevator, so that the landing speed does not change due to heavy objects. It is adjusted by the saving valve

The net height of the landing door opening should not be less than 8m and the difference between the net width and the outlet width of the cage door should not exceed 120mm. When the floor door is closed, except for the gap between the lower part of the door that should not exceed 35mm,ZhongshanBasement electric elevator, the size of any through-hole and opening related to the distance between any door and adjacent moving parts, as well as the gap around the door or between parts, should comply with the provisions of Table 4 of 'Mechanical Safety - Safety Distance to Prevent Upper and Lower Limbs from Touching Dangerous Areas' GB23821-2009.

.When the distance between the outer edge of the construction electric elevator and the edge line of the external overhead power line cannot meet the requirements in the table above, effective protective measures should be taken.

The angle between the wall bracket and the horizontal plane should comply with the requirements of the user manual.

Setting requirements: The landing door should be standardized and tooled.


ZhongshanFully automatic electric elevatorDevelopment is inevitable



Setting requirements: The guide rail should be rigid and flexible components such as wire ropes or chains should not be used.

The suspension cage movement can only be resumed after operator operation.

Double layer steel mesh: The diameter of the steel bars is 12mm, with a spacing of 200mm.

Quality assurance.The verticality of the guide rail frame should meet the requirements of the specifications.

There is no need to set up a computer room above the shaft like an elevator, and the top floor height can be installed at least 2.5 meters.

During the use period, the user unit should organize professional technical personnel to inspect the construction electric elevator monthly according to the standard requirements, and record the inspection results.


ZhongshanFully automatic electric elevatorDevelopment is inevitable



Setting requirements: The wall bracket should use the manufacturer's matching standard products.

Bidding.Setting requirements: The layout and installation of all cables and wiring of electric elevators should be able to prevent mechanical damage.

When a suspension cage with a rated load capacity acts on the buffer at a speed greater than the rated speed of 0.2m/s, the average deceleration of the suspension cage should not exceed 1g, and the time when the peak deceleration exceeds 5g should not exceed

The scissor type electric elevator is a widely used high-altitude operation special equipment. Its scissor mechanical structure ensures high stability of the lifting platform, wide working platform, and high bearing capacity, making the high-altitude operation range wider and suitable for multiple people to work simultaneously. It makes high-altitude operation more efficient and safer

Zhongshan.The verticality of the guide rail frame should meet the requirements of the specifications.

The wall bracket of the construction electric elevator should be intact and reliably fixed, and its attachment distance, wall bracket spacing, and end height must comply with the requirements of the 'User Manual'. The angle between the plane of the wall bracket and the normal direction of the attachment surface should not exceed 8 degrees;. When the attachment device does not meet the requirements of the 'User Manual' due to conditions, design, and production materials should be confirmed by the manufacturer or reviewed by the technical leader of the installation unit