DenverElevator electric microWhat are the common software failures of the system

announcer:hp935HP175192871 release time:2024-02-03 19:24:47

with a spacing of 200mm.

Model Example: Hanging Cage Specification: LABSC200/200TD3200x1500 Type I: 2900~3600 Type II: 2900~3600 Type V: 1800~250044003800 Technical Requirements: The load-bearing capacity of the foundation should be greater than P: P=(hanging cage weight+outer cage weight+total weight of guide rail frame+counterweight+load) x0.02 (kN).

Denver.The safety overtravel of limit switches and upper limit switches should comply with regulatory requirements.

The setting of the cable guide frame should comply with the user manual and regulatory requirements.

.Construction electric elevators should be equipped with cable guide frames and comply with regulatory requirements.

Drainage measures need to be considered around the foundation. (Drain the accumulated water on the foundation).

After the electric elevator passes the inspection the user unit shall organize the leasing unit, and supervision unit to conduct acceptance. For the implementation of construction general contracting installation unit, the acceptance shall be organized by the construction general contracting unit. The acceptance form should be signed by the relevant responsible person.


DenverElevator electric microWhat are the common software failures of the system



The distance between the electric hoist and overhead line in Electrical safety construction shall meet the specification requirements, otherwise protective measures shall be taken.

Savings, rate of increase and decrease. To ensure safe and reliable braking and prevent accidents, a hydraulic control one-way valve, also known as a hydraulic lock, is added to prevent hydraulic pipelines from exploding and self locking safely. Installed overloaded voice control alarm

Then, the lifting platform platform platform that carries the load needs to be balanced, and the lifting of goods should try to maintain a stable and uniform speed.

Quotation sheet.When a rigid 5000mm2 square or circular flat surface is applied with a normal force of 600N to either side of the door, the door may not meet the above requirements, but safety should be maintained.

When a rigid 5000mm2 square or circular flat surface is applied with a normal force of 600N to either side of the door, the door may not meet the above requirements, but safety should be maintained.

When the horizontal distance between the edge of the cage and the edge of the landing or between the cage and the landing door is greater than 150mm and there is no effective protection from other structures, the side protection device for the landing entrance should be equipped.


DenverElevator electric microWhat are the common software failures of the system



When the landing door is closed, the full width of the lifting passage opening should be covered.

technical service.After the electric elevator passes the inspection, the user unit shall organize the leasing unit, installation unit, and supervision unit to conduct acceptance. For the implementation of construction general contracting, the acceptance shall be organized by the construction general contracting unit. The acceptance form should be signed by the relevant responsible person.

Lowering platform, vehicle mounted lifting platform, self-propelled lifting platform, diesel engine curved arm self-propelled lifting platform,DenverMobile electric hydraulic elevator, folding arm lifting platform, cylinder sleeve lifting platform,DenverSmall 100kg electric elevator, aluminum alloy lifting platform, and special

In addition to ground protective fences, low level doors can be used. Low level doors should meet the following requirements: the height of the door should be between 1m and 2m. And there should be at least protective railings, a half height middle crossbar, and a toe board at least 150mm above the ground.

Denver.Work is essential, and the main protective accessories include safety belts, guardrails, protective covers, etc.

When the wall bracket cannot meet the requirements of the construction site, it should be designed and calculated separately.

The wall bracket of the construction electric elevator should be intact and reliably fixed and its attachment distance, wall bracket spacing, and end height must comply with the requirements of the 'User Manual'. The angle between the plane of the wall bracket and the normal direction of the attachment surface should not exceed 8 degrees;. When the attachment device does not meet the requirements of the 'User Manual' due to conditions, its calculation sheet, design, and production materials should be confirmed by the manufacturer or reviewed by the technical leader of the installation unit, and verified by experts.