KemonaFlagpole electric elevatorThings to pay attention to when choosing

announcer:hp935HP175192871 release time:2024-01-30 15:02:56

When the foundation is set on the roof or floor structure, the bearing capacity of its supporting structure should be checked.

When applying a normal force of 300N to any position on either side of the door using a rigid 5000mm2 square or circular flat surface in the locked position of the landing door, the door should be able to withstand and have no deformation; - Deformation not exceeding 30mm; After the test, it worked normally.

Kemona.Before use, we should observe whether there is any damage to the electric elevator. We can conduct a no-load test to raise and lower it. If there are any damaged parts, they should be replaced in a timely manner to prevent major accidents.

To meet the needs of choreographers and choreographers in different plays,KemonaElectric aluminum alloy elevator, different heights of the lifting platform can be used to change the shape of the stage according to the requirements of the choreographers and choreographers, in order to adapt to the requirements of the plot for the scenery or venue, and save manpower and material resources for setting up. By using the tilting device of the lifting platform to form a tilted platform, a better highlighting effect can be achieved in various performances. According to the needs of the plot, creating unexpected atmosphere and effects according to the needs of the plot. For example, it should be designed separately. The design of the wall bracket should meet the requirements of component stiffness using the valves on the lifting platform and the sudden disappearance and appearance of actors on the lifting platform.

.The bearing capacity of the ground under the concrete foundation plate should be greater than 0.15Mpa.

Mechanical devices controlled by cage movement should not be used to open or close the landing door.

The bearing capacity of the building structure at the attachment point of the wall bracket should meet the requirements specified in the user manual for construction electric elevators.


KemonaFlagpole electric elevatorThings to pay attention to when choosing



Low level doors should be equipped with interlocking devices that can verify their closed and locked positions. The action of this interlocking device should be at the entrance of the cage. Simple use should not interfere with the operation of the interlocking device. The attached wall bracket should use matching standard products. When the wall bracket cannot meet the requirements of the construction site, strength, stability, etc.,KemonaElectric hydraulic elevator 15 meters, and the production should meet the design requirements.

Setting requirements: A limit switch should be set at both the upper and lower ends of the stroke, which should be able to cut off the power supply before the suspension cage and other mechanical stop devices (such as buffers), so that the suspension cage can stop

The setting of the cable guide frame should comply with the user manual and regulatory requirements.

For more please check.Acceptance: Concrete strength grade C30, strength testing report.

Construction electric elevators should be equipped with cable guide frames and comply with regulatory requirements.

The motor of the hydraulic guide rail lifting platform is set around the wellbore, occupying a relatively small area, improving the utilization rate of the wellbore area.


KemonaFlagpole electric elevatorThings to pay attention to when choosing



The motor of the hydraulic guide rail lifting platform is set around the wellbore, occupying a relatively small area, improving the utilization rate of the wellbore area.

Free consultation.Installation and dismantling personnel and drivers should hold certificates to work.

If the set screw is loose,KemonaElectric elevator platform, be sure to pin it tightly to prevent accidents caused by the shaft pin falling off. Hydraulic oil should be kept clean and replaced every 6 months.

The spacing between wall brackets and the height of guide rails above the high attachment point should comply with the requirements of the user manual.

Kemona.The net height of the landing door opening should not be less than 8m, and the difference between the net width and the outlet width of the cage door should not exceed 120mm. When the floor door is closed, except for the gap between the lower part of the door that should not exceed 35mm, the size of any through-hole and opening related to the distance between any door and adjacent moving parts, as well as the gap around the door or between parts, should comply with the provisions of Table 4 of 'Mechanical Safety - Safety Distance to Prevent Upper and Lower Limbs from Touching Dangerous Areas' GB23821-2009.

Setting requirements: Drainage measures should be set up for the foundation of construction electric elevators to ensure smooth drainage.

Protective measures should comply with regulatory requirements.