OstrovinkaFixed lifting cargo elevatorstatistics

announcer:hp779HP136589660 release time:2024-05-04 09:14:48

For guideway elevators installed outdoors, they are often exposed to rain and sunlight, so special attention should be paid to regular maintenance and inspection to avoid accidents.

Before connecting the motor to the elevator, the elevator manufacturer should first make the motor shaft keyway perpendicular to the tightening bolt. To ensure uniform stress, first screw on the mounting bolts at any diagonal position, but do not tighten them. Then screw on the other two mounting bolts at diagonal positions, and then tighten the four mounting bolts one by one. After that tighten the tightening bolts. All tightening bolts shall be fixed with a torque wrench according to the indicated fixed torque data, and the use of elevators and lifting platforms shall be checked

Ostrovinka.After careful inspection, it was found that there were two main causes: loss of hydraulic pressure, and leakage of hydraulic valves or seals.

It is good for aerial work vehicles not to cover their clothes and park outside. If it is windy and rainy, the clothes will repeatedly slap the car paint, especially if the vehicle blows sand on the clothes, causing many fine scratches on them, as the paint will become black over time. In addition, when the wind does not directly spray powder or clean the mechanism on the sand, it should be washed with water, and prevent the vacuum cleaner of the aerial work vehicle from scratching the sand particles on the paint surface.

.Several types: motor winding open circuit. When one phase of the motor winding is open circuit, or one of the parallel branches is open circuit, it will cause three-phase current imbalance and cause the motor to overheat.

Test the goods elevator every day to see if it can operate normally.

Goods should be stacked well on the platform, and should not be tilted. When the goods elevator is lifting or lowering beyond the scope of the platform, no one should stand around to watch.


OstrovinkaFixed lifting cargo elevatorstatistics



Hydraulic pump station: domestic lifting platform dedicated pump station, Italian imported pump station with external protective devices: organ m type, mesh type and iron plate sealed type.

Small pneumatic or electric derusting, which uses the principle of friction generated by air compression or electromagnetic effects to polish and remove rust on the surface of a spiral elevator, can be used for precision instrument push rods or for enterprises that require micro operation of spiral elevators.

Hydraulic pump station: domestic lifting platform dedicated pump station, Italian imported pump station with external protective devices: organ m type, mesh type, and iron plate sealed type.

Analysis project.What is the new price of fixed elevators? Fixed elevators are currently very popular in the market. Due to different manufacturers, different materials, different load ratings, and different brand awareness,OstrovinkaFixed hydraulic lifting cargo elevator, the prices also vary. Currently,Ostrovinka13 meter guide rail type cargo elevator, the prices of fixed elevators produced in the domestic market are: rated load 1-5 tons, lifting height 7 meters, table size 2500 mm * 2000 mm and the price is around 27000-45000 yuan; The rated load is 1-3 tons, the lifting height is 0 meters, the table size is 2300 mm * 2000 mm and the price is around yuan. Rated load and lifting height of each fixed elevator, or muddy roads. The bottom and some gaps and indoor floors are prone to sludge accumulation. If the owner does not clean them in a timely manner, this can cause moisture to hide. Therefore, doors, bottom corners of tree trunks, key holes, and wiper brackets, as well as other areas, should be regularly inspected, and the drainage holes in the doors and various parts should be kept unblocked to ensure that the car seat covers, such as humidity, prevent rust from forming parts.


OstrovinkaFixed lifting cargo elevatorstatistics



Test the goods elevator every day to see if it can operate normally.

Bidding.Motor connection error. When the triangular connection motor is mistakenly connected into a star shape and floors, the motor still operates with full load, and the current flowing through the stator winding exceeds the rated current, leading to the motor stopping itself. If the stopping time is slightly longer and the power supply is not cut off, the winding will not only be severely overheated, but also burned. When a star connected motor is mistakenly connected into a triangle, or when several coil groups are connected in series into a single branch, the motor is mistakenly connected into two branches in parallel, both the windings and the iron core will overheat, and in severe cases, the windings will be burned.

What is the solution to the problem of rust on the surface of the spiral elevator? Sandpaper has a large loss on the spiral elevator itself. Specializing in products, renewable resources business, including: elevator factory

Incorrect connection of the elevator motor When a coil, coil group, or one phase winding group is connected inversely, it can cause a serious imbalance in the three-phase current and cause the winding to overheat.

Ostrovinka.Secondly, there should be no dirt on the friction surface. If there is any dirt, it should be washed off with gasoline or thinner; The reduction gearbox, gearbox, external meshing gear, and other parts of the equipment, as well as the hydraulic oil, must be tested according to the requirements in the table; Correct maintenance of the hydraulic guide rail elevator: Regularly inspect the wire ropes at various parts for broken wires and looseness. If any such phenomenon is found,OstrovinkaHydraulic lifting cargo elevator, tighten it in a timely manner. Check the tightness of the connecting bolts of the equipment when the body is under pressure. All connecting shafts should be equipped with cotter pins; Check whether the operation of each mechanism is normal, whether there are noises and faults according to regulations, and promptly remove all faults; When installing, disassembling, and adjusting the rotating mechanism of the equipment, it is important to note that the reducer and the gear center line should be parallel, and the meshing clearance should be appropriate; Regularly conduct a comprehensive inspection of the equipment to see if there is any damage to the wires and cables, boxes, distribution boxes, and brushes of the motor are kept clean, and that the travel switch points of each safety device must be safe and reliable.

The purpose of hydraulic lifting platform Users can choose the power mode and configuration according to their own scope of use: power systems include: DC power supply, single-phase or three-phase power supply, diesel engine.

It is strictly prohibited for personnel to climb up and down the floors by using the goods elevator privately.