BrugesElevating cargo elevator factory buildingThe company's losses are expanding rapidly

announcer:hp779HP136589660 release time:2024-05-02 18:00:28

the elevator manufacturer should first make the motor shaft keyway perpendicular to the tightening bolt. To ensure uniform stress

Before connecting the motor to the elevator, first screw on the mounting bolts at any diagonal position, but do not tighten them. Then screw on the other two mounting bolts at diagonal positions, and then tighten the four mounting bolts one by one. After that, and the use of elevators and lifting platforms shall be checked

Systems: explosion-proof electronic control system remote control system, PIC system.

Bruges.The main structure and use of the guide rail type elevator are closed gear transmission, and the large and small gears are made of steel. After quenching and tempering treatment, they belong to the soft tooth surface. As the common failure form of closed soft tooth surface gear transmission is tooth surface pitting, connecting tubes, and connecting pieces. The materials are all selected, including the thickness of both sides of the plate, products, and tens of millions of products. Professional elevator factory transactions are safe and guaranteed. At the same time, in order to reduce the weight of the bracket, many process holes are designed on both sides of the plate. The worm gear and worm mechanism has the advantages of large transmission ratio, compact structure, small impact load, stable transmission, low noise, and has the characteristics of reverse self-locking. It can ensure that the transmission mechanism can self-lock when the motor is powered off during patient handling, so a worm gear reducer is selected. The involute worm is used and the material is steel. Its spiral surface is quenched to improve transmission efficiency and increase wear resistance. The worm gear is made of polyformaldehyde. Plastic worm wheels have the advantages of good processing economy, stable transmission, vibration absorption and noise reduction, light weight, wear resistance, making the design of the elevator more humanized.

Nowadays, small and medium-sized enterprises are products with the idea of good quality and preferential prices.

.The cleanliness of the hydraulic station is an important aspect of the elevator hydraulic station, so it should not be taken lightly. Moreover, from a professional perspective, there are relevant rules and requirements. You should refer to the specification manual, so that you can have a correct understanding and know how to achieve better cleanliness.

The purpose of hydraulic lifting platform Users can choose the power mode and configuration according to their own scope of use: power systems include: DC power supply, single-phase or three-phase power supply, diesel engine.

Does the cleanliness of the hydraulic station have relevant rules and requirements?


BrugesElevating cargo elevator factory buildingThe company



Low cost: Compared to the scissor type mobile lifting platform, the cost is much lower. Therefore, when purchasing a lifting platform, it is necessary to consider the use range, frequency of work, load, and other factors of the lifting platform to select a lifting platform suitable for the work requirements.

Replace with new oil and do not intermittently use the old oil, otherwise the moving parts in the system will accelerate wear.

Does the cleanliness of the hydraulic station have relevant rules and requirements?

Quality department.To ensure excellent power supply at the installation site, install a separate distribution box. When using the distribution box,BrugesGuide rail lifting cargo elevator, the electrical leakage switch must meet the requirements for construction elevators. If the installed construction elevator is variable frequency, the selection of the leakage switch should be compatible with the frequency converter.

The water cooling of hydraulic stations is generally tubular water cooling, and the type selection is based on the heat load to calculate the heat exchange area, while the air-cooled elevator is conducted using an air cooler, and the heat exchange capacity is calculated based on the heat load. Then, the type selection calculation is performed when the flow can be satisfied. Therefore, the two types of cooling are different, and there are significant differences. Long-term lifting and lowering of cargo elevator factory

'Using the elevator is not about maintaining and overhauling the equipment after it has failed. It is important to maintain the equipment in accordance with the correct maintenance and overhaul. First, do the preparatory work to eliminate all possible fault problems and accidents. I hope that today's summary of knowledge points by the editor can help everyone.'.


BrugesElevating cargo elevator factory buildingThe company



Secondly, there should be no dirt on the friction surface. If there is any dirt, it should be washed off with gasoline or thinner; The reduction gearbox, gearbox, external meshing gear, and other parts of the equipment, must be tested according to the requirements in the table; Correct maintenance of the hydraulic guide rail elevator: Regularly inspect the wire ropes at various parts for broken wires and looseness. If any such phenomenon is found, replace it in a timely manner. The maintenance of the wire ropes must be carried out in strict accordance with the specifications; Check the connection condition of each part according to the braking rules and regulations. If there is any looseness, tighten it in a timely manner. Check the tightness of the connecting bolts of the equipment when the body is under pressure. All connecting shafts should be equipped with cotter pins; Check whether the operation of each mechanism is normal, whether there are noises and faults according to regulations, and promptly remove all faults; When installing, disassembling, and adjusting the rotating mechanism of the equipment, it is important to note that the reducer and the gear center line should be parallel and the meshing clearance should be appropriate; Regularly conduct a comprehensive inspection of the equipment to see if there is any damage to the wires and cables, and if there is overheating of the motor. Replace the motor in a timely manner and eliminate the fault before continuing operation; Ensure that the bearings, boxes, distribution boxes, and brushes of the motor are kept clean, and that the travel switch points of each safety device must be safe and reliable.

Product survey.The water cooling of hydraulic stations is generally tubular water cooling,Bruges5 ton cargo elevator, and the type selection is based on the heat load to calculate the heat exchange area, while the air-cooled elevator is conducted using an air cooler, and the heat exchange capacity is calculated based on the heat load. Then, the type selection calculation is performed when the flow can be satisfied. Therefore, the two types of cooling are different, and there are significant differences. Long-term lifting and lowering of cargo elevator factory

All previous inspections and commissioning have been carried out, and all technical indicators have met the design requirements. When using, it is only necessary to connect the power supply, and there is no need to adjust the hydraulic and electrical systems.

Walking: assisted self-propelled, two wheel traction, self driving, and car modification.

Bruges.What types of elevators are there? There are many types of such equipment, such as fixed lifting devices and vehicular lifting devices, depending on the form of movement. The so-called fixed lifting is generally installed in one place and fixed, and then lifting operations can be carried out. This type of lifting equipment is generally used more on the assembly line,BrugesElevating cargo elevator, and some large production lines need to lift the materials to a certain position when loading them, and then put them into production on the production line. A special lifting device needs to be fixed at a certain position on the production line.

Hydraulic pump station: domestic lifting platform dedicated pump station Italian imported pump station with external protective devices: organ m type, and iron plate sealed type.