dad1 ton small lifting cargo elevator5 ways to find faults

announcer:hp779HP136589660 release time:2024-04-02 12:31:51

After the goods are transported, clean the platform.

Purpose The hydraulic lift is widely used in various industrial enterprises and production lines such as automobile, mold manufacturing, wood processing, chemical filling etc., to meet the lifting requirements of different operation heights, and can be equipped with various table forms (such as ball, roller, turntable, steering, tipping, telescoping) and with various ways (separate, linkage, explosion-proof), it has the characteristics of stable and accurate lifting, frequent starting, and large load capacity, Effectively solve various lifting and lowering operation difficulties in industrial enterprises, strict testing, more affordable prices, and more preferential treatment. Welcome to consult

dad.Before using the machine, the staff should carefully check the hydraulic and electrical systems to ensure there is no leakage or bare leakage before using it.

For guideway elevators installed outdoors, they are often exposed to rain and sunlight, so special attention should be paid to regular maintenance and inspection to avoid accidents.

.Corrosion prevention measures for the body of aerial work vehicles Attention to small scratches The paint surface of aerial work vehicles often corrodes. In addition to common collisions, scratches, and small rocks on the drive tire, there can also be a paint peeling point that can cause a small rust over time. Because most of these scars are small and easy to ignore. Therefore, regularly inspect the engine compartment lid and surrounding areas, and once found, go to a professional beauty shop for processing in a timely manner.

Secondly, there should be no dirt on the friction surface. If there is any dirt,dadGuide rail chain lifting cargo elevator, it should be washed off with gasoline or thinner; The reduction gearbox, gearbox, external meshing gear, and other parts of the equipment, as well as the hydraulic oil, must be tested according to the requirements in the table; Correct maintenance of the hydraulic guide rail elevator: Regularly inspect the wire ropes at various parts for broken wires and looseness. If any such phenomenon is found, replace it in a timely manner. The maintenance of the wire ropes must be carried out in strict accordance with the specifications; Check the connection condition of each part according to the braking rules and regulations. If there is any looseness, tighten it in a timely manner. Check the tightness of the connecting bolts of the equipment when the body is under pressure. All connecting shafts should be equipped with cotter pins; Check whether the operation of each mechanism is normal, whether there are noises and faults according to regulations, and promptly remove all faults; When installing, disassembling, and adjusting the rotating mechanism of the equipment, it is important to note that the reducer and the gear center line should be parallel, and the meshing clearance should be appropriate; Regularly conduct a comprehensive inspection of the equipment to see if there is any damage to the wires and cables, and if there is overheating of the motor. Replace the motor in a timely manner and eliminate the fault before continuing operation; Ensure that the bearings, boxes, distribution boxes, and brushes of the motor are kept clean, and that the travel switch points of each safety device must be safe and reliable.

Prepare the foundation according to the foundation plan, pay attention to alignment,dadProduction of lifting cargo elevators, leveling, and alignment, and ensure the level of the foundation and various usage requirements.


dad1 ton small lifting cargo elevator5 ways to find faults



Several types: motor winding open circuit. When one phase of the motor winding is open circuit or one of the parallel branches is open circuit, it will cause three-phase current imbalance and cause the motor to overheat.

How to solve the problem of oil pipe leakage due to the sinking of the elevator? It may be caused by damaged seals or cracks in the oil pipe, resulting in a pressure drop and inability to support the oil pipe to a large height.

The anti rust work of aerial vehicles is generally something that needs attention when they have not been used for a long time. How should we protect the body of aerial vehicles from corrosion? This is actually a simple matter of not having to spend money on anti-corrosion at the repair station. As long as we car owners use some materials they can find on their own, we can achieve this. At the same time, paying attention to driving habits can ensure that high-altitude work vehicles do not rust. Here are a few points for reference.

Quality improvement.Connect the motor to the elevator naturally. During connection, it must be ensured that the concentricity of the elevator output shaft and the motor input shaft is consistent, and that the outer flanges of the two are parallel. Inconsistent centering can cause the motor shaft to break or the elevator gear to wear.

Outriggers: mechanical outriggers, hydraulic outriggers, ordinary hand cranking outriggers, and pull-out outriggers.

Before connecting the motor to the elevator, the elevator manufacturer should first make the motor shaft keyway perpendicular to the tightening bolt. To ensure uniform stress, but do not tighten them. Then screw on the other two mounting bolts at diagonal positions, and then tighten the four mounting bolts one by one. After that, tighten the tightening bolts. All tightening bolts shall be fixed with a torque wrench according to the indicated fixed torque data, and the use of elevators and lifting platforms shall be checked


dad1 ton small lifting cargo elevator5 ways to find faults



Walking: assisted self-propelled, two wheel traction, self driving, and car modification.

details.Systems: explosion-proof electronic control system, PIC system.

The main structure and use of the guide rail type elevator are closed gear transmission, they belong to the soft tooth surface. As the common failure form of closed soft tooth surface gear transmission is tooth surface pitting, the design is based on the tooth surface fatigue strength and checked based on the tooth root bending fatigue strength. The bracket bracket is used to fix and support all mechanical parts and some electrical components of the elevator chassis. It is mainly welded from parts such as side plates, connecting tubes, and connecting pieces. The materials are all selected, including the thickness of both sides of the plate, products, and tens of millions of products. Professional elevator factory transactions are safe and guaranteed. At the same time, in order to reduce the weight of the bracket, compact structure, small impact load, stable transmission, low noise, and has the characteristics of reverse self-locking. It can ensure that the transmission mechanism can self-lock when the motor is powered off during patient handling, so a worm gear reducer is selected. The involute worm is used and the material is steel. Its spiral surface is quenched to improve transmission efficiency and increase wear resistance. The worm gear is made of polyformaldehyde. Plastic worm wheels have the advantages of good processing economy, vibration absorption and noise reduction stable transmission, light weight, wear resistance, and self reliance, making the design of the elevator more humanized.

Frequently check for water accumulation and humidity. It is inevitable for aerial vehicles to drive in rainy and snowy weather, this can cause moisture to hide. Therefore, activities in the outer edges of wheel hubs, doors, bottom corners of tree trunks, key holes, and wiper brackets, as well as other areas, should be regularly inspected, and the drainage holes in the doors and various parts should be kept unblocked to ensure that the car seat covers, such as humidity, carpets, and floors, prevent rust from forming parts.

dad.Fixed elevator is a transportation equipment that directly lifts and loads goods from the ground. It is mainly used for goods transportation between height differences in production lines, material loading and unloading, component lifting during assembly of large equipment, fixed three-dimensional parking, and other places. So what is the new price for fixed elevators?

Does the cleanliness of the hydraulic station have relevant rules and requirements?

To ensure excellent power supply at the installation site, install a separate distribution box. When using the distribution box, the electrical leakage switch must meet the requirements for construction elevators. If the installed construction elevator is variable frequency, the selection of the leakage switch should be compatible with the frequency converter.