BIVA podraskaUsed electric elevator platformIndustry development trend analysis

announcer:hp935HP175192871 release time:2024-08-05 09:46:54

The foundation production and acceptance of electric elevators for foundation construction should comply with the user manual and regulatory requirements.

Setting requirements: The layout and installation of all cables and wiring of electric elevators should be able to prevent mechanical damage.

BIVA podraska.Savings, rate of increase and decrease. To ensure safe and reliable braking and prevent accidents,BIVA podraskaMobile small electric elevator, a hydraulic control one-way valve, also known as a hydraulic lock, is added to prevent hydraulic pipelines from exploding and self locking safely. Installed overloaded voice control alarm

The distance between the electric hoist and overhead line in Electrical safety construction shall meet the specification requirements, otherwise protective measures shall be taken.

.The safety bulletin board for construction electric elevators should be hung at the protective shed of the electric elevator, with a size of 8 meters by 2 meters.

Setting requirements: The landing door should be standardized and tooled.

Especially suitable for steel structured factories, suitable for both indoor and outdoor installation.


BIVA podraskaUsed electric elevator platformIndustry development trend analysis



The scaffolding of the parking platform should be laid tightly and firmly.

Lowering platform, vehicle mounted lifting platform, self-propelled lifting platform, diesel engine curved arm self-propelled lifting platform, folding arm lifting platform, cylinder sleeve lifting platform, aluminum alloy lifting platform, and special

Work is essential,BIVA podraskaSmall mobile electric elevator, guardrails, protective covers, platforms and stairs, etc.

A complete range of products.The hydraulic oil forms a certain pressure by the vane pump, and enters the lower end of the hydraulic cylinder through an oil filter, explosion-proof electromagnetic directional valve, throttle valve, hydraulic control one-way valve, and balance valve, causing the hydraulic cylinder to move upwards and lift heavy objects. The return oil at the upper end of the hydraulic cylinder returns to the oil tank through the explosion-proof electromagnetic directional valve, and its rated pressure overflow valve is adjusted. The pressure gauge observes the reading value on the pressure gauge. The downward movement of the hydraulic cylinder (i.e. lowering of heavy objects).

When the horizontal distance between the edge of the cage and the edge of the landing or between the cage and the landing door is greater than 150mm and there is no effective protection from other structures the side protection device for the landing entrance should be equipped.

The landing door should meet the requirements of the specifications and achieve standardization.


BIVA podraskaUsed electric elevator platformIndustry development trend analysis



The landing door should be in a normally closed state. Without the permission of the construction electric elevator driver, the landing door shall not be opened.

safety requirements .When a rigid 5000mm2 square or circular flat surface is applied with a normal force of 600N to either side of the door, the door may not meet the above requirements, but safety should be maintained.

Attention should be paid to the occurrence of oil leakage on the aluminum alloy lifting platform to avoid secondary damage caused by a shortage of hydraulic oil. Overloading work is prohibited during use

A complete lifting platform accessory can be selected and customized according to different places, venues and environmental usage conditions. Meet the needs of different users. So why lifting platforms can be used and installed in so many industries and places is because they can achieve multi-purpose, demonstrate multifunctional, meet various different needs, and win market demand. In modern industrial transportation processes, lifting platforms have begun to play an increasingly important role, whether in airports, docks, workshops and other places that require rapid loading and unloading of goods, they have played a very practical value, It has also brought great contributions to the entire industry and even the entire economic development. However, long-term operation and use of these devices inevitably lead to wear and consumption, and regular maintenance and upkeep are essential. Otherwise,BIVA podraskaGuide rail electric elevator, both work efficiency and utilization rate will decrease, and at that time, the gains and losses will outweigh the losses.

BIVA podraska.Steel wire ropes, pulleys, and counterweight steel wire ropes shall comply with the following regulations: the characteristics of steel wire ropes shall comply with the requirements of General Purpose Steel Wire Ropes GB/T20118; Maintenance, wear, deformation and corrosion of steel wire ropes

There is no need to set up a computer room above the shaft like an elevator, and the top floor height can be installed at least 2.5 meters.

When the door is closed, except for the gap between the lower part of the door that should not exceed 35mm, any through-hole and opening size related to the distance between any door and adjacent moving parts, as well as the gap around the door or the gap between parts, should comply with the provisions of Table 4 of GB 23821-2009.