MiamiElectric hydraulic platform lift truckHow to take measures for large-scale enterprises

announcer:hp237HP184976196 release time:2024-08-04 14:06:54

When repairing the elevator, shortness of breath there are many precautions to pay attention to during the maintenance process. We have summarized the relevant matters for your reference only.

It is strictly prohibited to run the engine for a long time in a closed garage. The exhaust gas from the elevator engine contains carbon monoxide. This is a toxic gas that has been exposed to low concentrations of carbon monoxide for a long time. It can cause symptoms such as headache, nausea and vomiting, body weakness and dizziness, psychological confusion, and even brain damage. In severe cases, it can cause death, such as starting the engine of the equipment in the garage.

Miami.Lifts, due to their superior performance and convenient use, occupy a large share in the heavy machinery industry and have always been trusted by customers.

Therefore, the use of stable voltage in elevators is crucial for safe operation. Elevators have high stability a wide working platform, and a high load-bearing capacity, making high-altitude operations more efficient and safe. To avoid the harm of voltage instability, please ensure voltage stability.

.The self walking high-altitude work platform has strong adaptability and can be used in harsh environments and general explosion-proof places.

Single mast elevator Standard configuration of single mast elevator: platform height specifications: optional 4m, 6m, 8m, 9m; Power supply: single-phase AC (AC220V/50HZ), other forms can be optional; Movement method: manual traction.

What are the configuration requirements for the upcoming elevator; Generally speaking, the higher the configuration requirements of a lift, the higher the price of the lift. Users should be aware of this, so they must choose the appropriate model and configuration based on their own needs, not only to avoid resource waste but also to ensure the production efficiency of the lift.


MiamiElectric hydraulic platform lift truckHow to take measures for large-scale enterprises



The entire elevator is made of high-strength aluminum profiles which have high strength, beautiful appearance, small size, light weight,MiamiSmall mobile hydraulic lifting platform, compact structure, convenient movement, stable lifting platform, and are suitable for use in factories,MiamiLifting hydraulic lifting platform, hotels buildings, stations, airports, etc.

Ensure that the distance between the upper and lower limit switches and the limit iron is within the 0.2-2mm boundary between the limit switch handle and the upper and lower limit iron when the limit switch is disconnected. After adjusting the limit switch and limit switch appropriately, you can proceed with the assembly of the guide rail frame, attachment frame, and cable guide frame.

Equipped with anti fall safety protection devices to prevent pipeline bursting. Various mobile elevator manufacturers have formal qualifications. Welcome to inquire by phone and sincerely invite cooperation!

Product line.Drain and discard the hydraulic oil, tighten the joint,MiamiHydraulic lifting platform, remove the oil filter, clean it with compressed air, and then return it to the oil tank and connect the pipeline.

After the elevator is lifted, it is necessary to fully study the maintenance manual of the elevator and do a good job in use and maintenance. In the detection of various indicators of the elevator, it is necessary to follow the regulations and ensure that the elevator is idle.

Industry platforms are also tailored for various types of company populations. The elevator can be roughly divided into


MiamiElectric hydraulic platform lift truckHow to take measures for large-scale enterprises



Firstly, the maintenance process should be carried out on the premise of ensuring the safety of staff. Before repairing the elevator, the power must be disconnected, and the power must be verified and hung up; No power transmission, people working&# quo; Identification plate for. During the maintenance process, it is not allowed to disconnect the grounding wire of the elevator. If it is necessary for maintenance work, after the maintenance is completed, the grounding wire must be connected before the power test can be conducted. When replacing elevator spare parts, it is necessary to ensure that the spare parts are available

How much is it.The hydraulic system is equipped with an emergency descent function to prevent power outages and unexpected situations, and the emergency operation is simple.

Therefore, high-altitude work equipment has received increasing attention, and the continuous development and innovation of lifting and lowering have gained the trust and use of customers. The following is an introduction by the editor to everyone: The operation status of the elevator. The elevator products are made of high-strength and high-quality materials, which can be divided into single mast column type, double mast column type, three mast column type, and four single pillar type according to the lifting height. The elevators use high-strength and high-quality materials, which have the advantages of beautiful appearance, small volume, light weight, smooth lifting, safety and reliability. Below, the editor will introduce the product description of the single column elevator.

We are well aware of the harm of pressure, but how can we prevent water from seeping into the hydraulic system of the elevator? After reading this article, you may know that oil contains excessive water impurities, which can rust the hydraulic components of the elevator, reduce the strength of the oil film, and accelerate mechanical wear. In addition to preventing water impurities from invading during maintenance, it is also important to note that when the oil storage tank is not in use, the cover should be tightened and placed upside down; Oil with high water content needs to be filtered multiple times and the hydraulic oil of the elevator that is filtered each time needs to be replaced with a dry filter paper. In the absence of specialized instruments for detection, the oil can be dropped onto the hot iron plate, and no steam can be emitted before being added immediately. So when repairing the hydraulic system of aluminum alloy, be careful of the entry of moisture!

Miami.The single column elevator is an indoor type, widely used for high-altitude operations in various industries such as star hotels and large supermarkets. It has balanced lifting and easy operation, and can enter general lobbies. It can easily enter and exit the elevator with low power consumption, no pollution, and does not harm the ground during work. It can be used for wall sticking and exploration work, and there are no dead corners during work.

Blow out the plunger with compressed air, then install it and reinstall it.

The scientific design schemes for elevators mainly include leveling and locking circuits, variable amplitude balance circuits, emergency lowering systems, etc. In order to prevent sudden damage to the hydraulic system or pipelines of the platform due to accidents, and to ensure that the workbench does not experience situations that endanger the safety of personnel and equipment such as sudden arm fall or workbench overturning, we have designed different solutions for each system according to its different conditions.