CincinnatiHydraulic lifting platform smallFeatures of Pneumatic Conveying System

announcer:hp391HP142030639 release time:2024-07-21 10:01:46

When the motor overheats, it should be stopped immediately, and after troubleshooting, it should continue to operate. The motor bearings should be in good condition.

For customers to use and operate the lifting platform for a long time, the editor briefly introduces how to maintain and repair the lifting platform: First of all,CincinnatiHydraulic fixed lifting platform, normal maintenance is mainly focused on prevention, especially if any damage or malfunction is detected and corrected or repaired in a timely manner. Careful inspection and maintenance at this time can save costs and avoid larger problems, resulting in costly repairs.

Cincinnati.When using a hydraulic lifting cargo elevator, it is necessary to have corresponding inspection routes. If the route malfunctions and the joint becomes loose, it is necessary to turn it on or off properly. In this case, there may be short lines or damaged components. Using a table for inspection is relatively better.

For homepage | add favorites | email | QQ: If you have any questions, please QQ us!

.Staying below high-altitude work sites is prohibited, and safety nets or other protective devices should be installed below the work site to avoid injury from falling objects.

Troubleshooting: When the elevator power light is turned on, press the up button, the motor rotates, but the lifting platform does not rise. This may be due to the reversal of the motor after the three-phase power supply is connected, just change the two phase wires of the heavy machine.

In short, when using a fixed loading and unloading platform, there is basically no need to worry about stability, as the manufacturer has taken many measures in this regard, providing more guarantees, so many times it can be used with confidence.


CincinnatiHydraulic lifting platform smallFeatures of Pneumatic Conveying System



The above detailed introduction, I believe everyone has a certain understanding of elevator selection, so that they can have a clear goal when choosing, and then choose the elevator that is suitable for customers.

Of course, the hydraulic lifting platform uses a dual protection structure, which can make the work relatively safer. When lifting, an appropriate working surface can be selected, so that the lifting platform will be safer during operation. The process of operating the hydraulic lifting platform should be standardized, so that maintenance and debugging can be carried out before leaving the factory. At the same time, it can also ensure that all technical indicators can meet the design requirements, but it is necessary to connect the ground wire during use. Of course, the hydraulic electrical system does not need to be adjusted in this situation.

Pay attention to checking each part of the steel wire rope for broken wires and loose strands. If the tide passes through the relevant regulations, it must be replaced immediately. The maintenance and upkeep of steel wire ropes should strictly follow the provisions of GB5144-85.

Recommendation and consultation.Everyone knows that construction elevators are used during the construction process because they have stability,CincinnatiFixed electric hydraulic lifting platform, are sturdy and reliable during use, and are widely used in the field of high-rise buildings due to their small size and other advantages.

When working at heights exceeding 1.5 meters, safety nets or safety belts must be used.

Secondly, the lifting platform is driven by electrical energy and lifted by the hydraulic system. During operation, it is necessary to avoid irregular operations. To ensure the normal and orderly operation of the lifting platform and achieve the ideal unloading level, timely inspection of various functions is essential.


CincinnatiHydraulic lifting platform smallFeatures of Pneumatic Conveying System



Drain all the hydraulic oil in the oil tank, open the oil tank, take out the oil suction filter, clean it, and return it to the oil tank. Install it in its original position. Fill the fuel tank with new oil.

Work courses.Shafts must have split pins and be sufficient.

Of course, the hydraulic lifting platform uses a dual protection structure, so that the lifting platform will be safer during operation. The process of operating the hydraulic lifting platform should be standardized an appropriate working surface can be selected, so that maintenance and debugging can be carried out before leaving the factory. At the same time, it can also ensure that all technical indicators can meet the design requirements, but it is necessary to connect the ground wire during use. Of course, the hydraulic electrical system does not need to be adjusted in this situation.

If there are problems inside the elevator and electrical professionals are present, any components of the hydraulic system should be disassembled and repaired in a completely depressurized condition.

Cincinnati.The current fixed hydraulic elevators are mainly enclosed or meshed lifting channels surrounded by buildings and light steel structures, oil pumps, safety valves fixed hydraulic lifting platform speed control valves The small oil tank cylinder part of hydraulic components such as directional valves: composed of one or more cylinders of a lifting cylinder, a straight top platform, or a lifting shear fork frame forming a door system. The closed or mesh platform door or door system consists of a steel structure, with manual and automatic doors. Generally, open platforms do not have doors. The electrical part is composed of power, signal, safety, lighting, and other devices. The platform part is a steel structure platform that carries heavy objects, There are enclosed (i.e. cabin type) or open types, with guide rollers or guide shoes on both sides. The platform bottom can be connected to the lifting cylinder or lifting scissor type steel frame auxiliary parts, which are composed of hydraulic pipe fittings, and steel structure bases; Safety devices: safety valves pressure gauges, limit limits,CincinnatiSmall electric hydraulic lifting platform, door electromechanical interlocking, rupture valves, emergency switches, non electrical professionals are not allowed to disassemble and assemble electrical appliances at will to prevent accidental connection or electric shock!

When using the elevator, the legs must be opened first. If the legs are not lifted, it is strictly prohibited to lift them.