Cage wooden boxSmall electric automatic elevatorWhat is the role of description

announcer:hp935HP175192871 release time:2024-07-16 10:25:47

the safety distance can be 0.40m.

The scissor type electric elevator is a widely used high-altitude operation special equipment. Its scissor mechanical structure ensures high stability of the lifting platform

The safety distance between the outer edge of the upper part of the landing door and the moving parts of the electric elevator during normal operation should not be less than 0.75m; If the rated speed is not greater than 0.7m/s, wide working platform, and high bearing capacity, making the high-altitude operation range wider and suitable for multiple people to work simultaneously. It makes high-altitude operation more efficient and safer

Cage wooden box.Lower limit switch: In normal working state, before the suspension cage touches the buffer, the lower limit switch first acts.

Protective measures should comply with regulatory requirements.

.During loading and unloading, the horizontal distance between the edge of the cage door and the edge of the landing station should not exceed 50mm.

Steel wire ropes, pulleys, and counterweight steel wire ropes shall comply with the following regulations: the characteristics of steel wire ropes shall comply with the requirements of General Purpose Steel Wire Ropes GB/T20118; Maintenance, wear, deformation and corrosion of steel wire ropes

The net height of the landing door opening should not be less than 8m, and the difference between the net width and the outlet width of the cage door should not exceed 120mm. When the floor door is closed, except for the gap between the lower part of the door that should not exceed 35mm, the size of any through-hole and opening related to the distance between any door and adjacent moving parts, should comply with the provisions of Table 4 of 'Mechanical Safety - Safety Distance to Prevent Upper and Lower Limbs from Touching Dangerous Areas' GB23821-2009.


Cage wooden boxSmall electric automatic elevatorWhat is the role of description



Many theaters use a lifting platform as a vertical transportation tool for goods. The rear of the main stage or the end of the side stage in many theaters are equipped with a set container transportation lifting platform, which is used to vertically transport items from the ground to a designated location or even the stage plane. The lifting platform of the music pool is often used for transporting movable seats,Cage wooden boxMicro electric hoist, etc.

Before each shift of work, with a size of 8 meters by 2 meters.

Implementing multiple shifts of homework should fill in and submit records according to regulations.

Civil engineering advantages: The pit depth of the guide rail type lifting platform is generally around 150-300mm, and the top layer is not affected. It can be customized according to the location and environment.


Cage wooden boxSmall electric automatic elevatorWhat is the role of description



Implementing multiple shifts of homework should fill in and submit records according to regulations.

Market trend.The landing door should meet the requirements of the specifications and achieve standardization.

Only after the operation of professional personnel can the suspension cage movement be restored.

The bearing capacity of the building structure at the attachment point of the wall bracket should meet the requirements specified in the user manual for construction electric elevators.

Cage wooden box.In addition to ground protective fences, low level doors can be used. Low level doors should meet the following requirements: the height of the door should be between 1m and 2m. And there should be at least protective railings,Cage wooden boxRechargeable electric elevator, a half height middle crossbar, and a toe board at least 150mm above the ground.

Setting requirements: For construction electric elevators with foundations installed on roof slabs, floors,Cage wooden box10 meter self-propelled elevator, or other lower suspended structures, the bearing capacity of the foundation support structure should be checked. Click here to download the construction technical information for free. Basic drainage facilities should be installed.

When the door is closed, except for the gap between the lower part of the door that should not exceed 35mm, any through-hole and opening size related to the distance between any door and adjacent moving parts, as well as the gap around the door or the gap between parts, should comply with the provisions of Table 4 of GB 23821-2009.