AnshanElectric vertical elevatorMeticulous workmanship

announcer:hp935HP175192871 release time:2024-07-10 13:13:25

Setting requirements: The wall bracket should use the manufacturer's matching standard products.

When the distance between the outer edge of the construction electric elevator and the edge line of the external overhead power line cannot meet the requirements in the table above, effective protective measures should be taken.

Anshan.Setting requirements: The up travel (limit) switch should be able to automatically stop the cage running at the rated speed before reaching the upper limit switch, but should not trigger the up travel (limit) switch as high

A complete lifting platform accessory can be selected and customized according to different places, venues, and environmental usage conditions. Meet the needs of different users. So why lifting platforms can be used and installed in so many industries and places is because they can achieve multi-purpose, demonstrate multifunctional meet various different needs, and win market demand. In modern industrial transportation processes, lifting platforms have begun to play an increasingly important role, whether in airports, docks, warehouses, floors, workshops and other places that require rapid loading and unloading of goods, they have played a very practical value, long-term operation and use of these devices inevitably lead to wear and consumption, and regular maintenance and upkeep are essential. Otherwise both work efficiency and utilization rate will decrease, and at that time, the gains and losses will outweigh the losses.

.Setting requirements: Drainage measures should be set up for the foundation of construction electric elevators to ensure smooth drainage.

Installation verticality deviation guide rail frame erection height, h/mH≤ 7070100150H& gt; 200 verticality deviation/mm≤ (1/100h≤ 70≤ 90≤ 110≤ 130 pairs of steel wire rope construction electric elevators, the verticality deviation of the guide rail frame should not exceed (5/1000) h.

To meet the needs of stage craftsmanship and layout; Product; In the music and dance theater stage arranged in a zigzag pattern, auxiliary lifting platforms are often arranged in front, back,AnshanNiuli brand electric elevator, and right of the main stage lifting platform. The side and rear auxiliary lifting platforms are used for the smooth opening of the side platform and rear vehicle turntable, while the front auxiliary lifting platform is used to place the rear vehicle turntable near the platform entrance. The leveling lifting platform below the side platform and rear vehicle turntable can be used to level the platform after the side platform or rear vehicle turntable is driven out, so that the entire platform does not have a height difference, ensuring the safety of the cast members.


AnshanElectric vertical elevatorMeticulous workmanship



When the horizontal distance between the edge of the cage and the edge of the landing or between the cage and the landing door is greater than 150mm and there is no effective protection from other structures, the side protection device for the landing entrance should be equipped.

Construction electric elevators should be equipped with safety devices to prevent the cage from falling. The anti fall safety device should be functional at all times, disassembly, and before resetting after action. Fall arrest safety gear

Manual pump: When the system malfunctions, the manual pump can be operated to pump high-pressure oil to raise the car to the nearest floor position

Customer first.The foundation production and acceptance of electric elevators for foundation construction should comply with the user manual and regulatory requirements.

The list of materials for making landing doors is as follows: Table 1: List of materials for making landing doors. Landing doors should be installed at the entrance of each landing station, and the landing doors should function properly.

The angle between the wall bracket and the horizontal plane should comply with the requirements of the user manual.


AnshanElectric vertical elevatorMeticulous workmanship



Setting requirements: When the distance between the outer edge of the construction electric elevator and the external overhead power line cannot meet the requirements of a small safety distance, the protective measures taken should comply with the specification requirements.

Where is good.When the door is closed, except for the gap between the lower part of the door that should not exceed 35mm, any through-hole and opening size related to the distance between any door and adjacent moving parts,AnshanStage electric elevator,AnshanElectric screw elevator, as well as the gap around the door or the gap between parts, should comply with the provisions of Table 4 of GB 23821-2009.

Stop.

Implementing multiple shifts of homework should fill in and submit records according to regulations.

Anshan.Horizontal lead screw mechanical electricity

There is no need to set up a computer room above the shaft like an elevator, and the top floor height can be installed at least 2.5 meters.

Horizontal lead screw mechanical electricity