Mason AlfordPortable electric elevatorWhich fields can be applied

announcer:hp935HP175192871 release time:2024-07-07 11:31:00

When the wall bracket cannot meet the requirements of the construction site, it should be designed and calculated separately.

The distance between the electric hoist and overhead line in Electrical safety construction shall meet the specification requirements, otherwise protective measures shall be taken.

Mason Alford.Installation position of upper limit switch: Under normal working conditions, the distance between the upper limit switch and the upper limit switch is 0.15m for SC type construction electric elevators,Mason AlfordElectric bed elevator, and 0.15m for SS type construction electric elevators (person)

When applying a normal force of 300N to any position on either side of the door using a rigid 5000mm2 square or circular flat surface in the locked position of the landing door, the door should be able to withstand and have no deformation; - Deformation not exceeding 30mm; After the test, it worked normally.

.Flat screw mechanical electric lifting mechanism: The lifting platform of this structure has the advantages of small civil engineering coordination, shallow foundation pit required, large stroke, stable operation, low noise accurate positioning, and low cost. Adopting a horizontal screw drive and a scissor fork structure to achieve the lifting motion of the table, it can be stopped arbitrarily within the range of travel.

The safety bulletin board for construction electric elevators should be hung at the protective shed of the electric elevator, with a size of 8 meters by 2 meters.

The setting of the cable guide frame should comply with the user manual and regulatory requirements.


Mason AlfordPortable electric elevatorWhich fields can be applied



The advantages and disadvantages of several commonly used electric lifting mechanisms are as follows: hydraulic electric lifting mechanisms: using hydraulic technology, smooth lifting and low noise.

The shutdown device (emergency stop switch) should be non automatic reset type.

Acceptance: Concrete strength grade C30, strength testing report.

Quality management.In addition to ground protective fences, low level doors can be used. Low level doors should meet the following requirements: the height of the door should be between 1m and 2m. And there should be at least protective railings, a half height middle crossbar, and a toe board at least 150mm above the ground.

The entrance of each landing platform must be equipped with a landing door, which must open towards the landing platform side, and the door bolt must be set on the side next to the construction electric elevator.

Mechanical devices controlled by cage movement should not be used to open or close the landing door.


Mason AlfordPortable electric elevatorWhich fields can be applied



During the use period, the user unit should organize professional technical personnel to inspect the construction electric elevator monthly according to the standard requirements,Mason AlfordSmall electric mobile elevator, and record the inspection results.

Respect for customers.The wall bracket of the construction electric elevator should be intact and reliably fixed, and its attachment distance, wall bracket spacing, and end height must comply with the requirements of the 'User Manual'. The angle between the plane of the wall bracket and the normal direction of the attachment surface should not exceed 8 degrees;. When the attachment device does not meet the requirements of the 'User Manual' due to conditions, its calculation sheet, and production materials should be confirmed by the manufacturer or reviewed by the technical leader of the installation unit,Mason Alford10 meter electric lifting platform, and verified by experts.

The usual operation of landing and docking.

Speed limit wire rope switch. When the speed limit wire rope trips or breaks. Make the electric elevator unable to start.

Mason Alford.The safety notice board for construction electric elevators should be prominently placed on the hanging cage for the rated load capacity and rated number of passengers of the construction electric elevator. It is strictly prohibited to use construction electric elevators beyond the rated load capacity or rated number of passengers.

To meet the needs of stage craftsmanship and layout; Product; In the music and dance theater stage arranged in a zigzag pattern, back, left and right of the main stage lifting platform. The side and rear auxiliary lifting platforms are used for the smooth opening of the side platform and rear vehicle turntable, while the front auxiliary lifting platform is used to place the rear vehicle turntable near the platform entrance. The leveling lifting platform below the side platform and rear vehicle turntable can be used to level the platform after the side platform or rear vehicle turntable is driven out, so that the entire platform does not have a height difference, ensuring the safety of the cast members.

The bearing capacity of the ground under the concrete foundation plate should be greater than 0.15Mpa.