Pesack6-meter electric elevatorWhat to pay attention to when professional

announcer:hp935HP175192871 release time:2024-06-28 19:07:08

Electric elevators used in various places.

The safety bulletin board for construction electric elevators should be hung at the protective shed of the electric elevator,PesackElectric elevators for elderly care, with a size of 8 meters by 2 meters.

Pesack.And the decoration team is also using aluminum alloy electric elevators. What safety considerations should we consider during the use process? Many manufacturers have not clearly indicated it. Today, the mechanical editor will talk to you about aluminum alloys

Buffer. In order to increase the energy for the car to hit the top or sink to the bottom. Remove rubber or sponge from the buffer and cabin to increase their impact energy; Rope groove slipping and other accidents caused the car to suddenly fall, resulting in a safety clamp. To prevent breakage of the lifting wire rope. A safety clamp that can simultaneously cut off the power supply and stop the car from falling should be removed from the car. A car without safety tongs is not allowed to ride or carry people. If it is a simple electric elevator, there should be a safety device (such as a safety stop pin) to prevent people from suddenly falling when loading and unloading goods in the car; Electric elevators with three or more floors (including three floors) for passengers or passengers.

.From the above comparison, it can be seen that hydraulic electric lifting mechanisms have stable lifting, low noise, long service life, large load bearing capacity, and are relatively simple, making them suitable for use in stage equipment.

Setting requirements: The foundation and foundation of the construction electric elevator should meet the requirements of the user manual. Before installing the construction electric elevator, the foundation should be inspected and accepted according to the requirements of the specifications. Only after passing the inspection can the installation be carried out.

Setting requirements: The wall bracket should use the manufacturer's matching standard products.


Pesack6-meter electric elevatorWhat to pay attention to when professional



When a rigid 5000mm2 square or circular flat surface is applied with a normal force of 600N to either side of the door, the door may not meet the above requirements, but safety should be maintained.

Setting requirements: Construction electric elevators should be equipped with a down travel (limit) switch. The down travel (limit) switch should be able to automatically stop the cage running at rated speed before reaching the lower limit switch.

Emergency manual valve: In case of power failure,PesackMultifunctional electric elevator, it can cause the car to descend to the nearest floor position and open the door

Quality assurance.The entrance of each landing platform must be equipped with a landing door, which must open towards the landing platform side,PesackSmall electric screw elevator, and the door bolt must be set on the side next to the construction electric elevator.

When the distance between the outer edge of the construction electric elevator and the edge line of the external overhead power line cannot meet the requirements in the table above, effective protective measures should be taken.

According to the needs of different performance genres, the form of the stage can be changed. For example, using an orchestra pit lift can combine a framed stage with a large lip or even an extended stage. In an experimental theater, using a lift can make the theater have various forms such as an end stage, an extended stage, an island stage, an intermediate stage, a T-shaped stage, or a hall.


Pesack6-meter electric elevatorWhat to pay attention to when professional



During normal operation the horizontal distance between the closed cage door and the closed landing door should not exceed 150mm. Otherwise, or side protection devices at the entrance of the landing station that meet the requirements should be equipped. The distance between any opening between the side protection device and the hanging cage or landing door should not exceed 150mm.

Credit guarantee.Setting requirements: For construction electric elevators that operate in multiple shifts measures should be taken to make it meet the requirements, the handover system should be implemented, including installation, disassembly, it can ensure that the equipment does not tilt during operation. Gear and rack electric lifting mechanism: precise transmission and high cost.

Pesack.After the electric elevator passes the inspection, the user unit shall organize the leasing unit, installation unit, and supervision unit to conduct acceptance. For the implementation of construction general contracting, the acceptance shall be organized by the construction general contracting unit. The acceptance form should be signed by the relevant responsible person.

The foundation production and acceptance of electric elevators for foundation construction should comply with the user manual and regulatory requirements.

Setting requirements: The guide rail should be rigid and flexible components such as wire ropes or chains should not be used.