DalasElectric tatami elevatorFactors affecting use

announcer:hp935HP175192871 release time:2024-06-11 11:17:05

The L distance depends on the selected wall mount model.

The distance between the electric hoist and overhead line in Electrical safety construction shall meet the specification requirements, otherwise protective measures shall be taken.

Dalas.Limit switches should be triggered directly by the movement of the suspension cage or its related components.

Protective measures should comply with regulatory requirements.

.The end height of the guide rail frame above the high attachment point should comply with the provisions of the user manual.

When the wall bracket cannot meet the requirements of the construction site, it should be designed and calculated separately.

Installation and dismantling personnel and drivers should hold certificates to work.


DalasElectric tatami elevatorFactors affecting use



The landing door should meet the requirements of the specifications and achieve standardization.

Precautions during operation: Mechanical operations should be gentle and smooth, and mechanical operations should be avoided, causing frequent mechanical failures and greatly shortening the service life. Generated during homework

When the landing door is closed, the full width of the lifting passage opening should be covered.

investment.The motor of the hydraulic guide rail lifting platform is set around the wellbore, occupying a relatively small area, improving the utilization rate of the wellbore area.

Setting requirements: The wall bracket should use the manufacturer's matching standard products.

There is no need to set up a computer room above the shaft like an elevator,DalasElectric scissor lift, and the top floor height can be installed at least 2.5 meters.


DalasElectric tatami elevatorFactors affecting use



The full height landing door should meet the following requirements: the net height of the landing door opening should not be less than 0m. In special circumstances, when the net height of the building entrance is less than 0m, it is allowed to lower the height of the lower door opening, but in any case, the net height of the lower door opening is not less than 8m. (Article 1 of GB26557-2011)

Administration.The wall bracket of the construction electric elevator should be intact and reliably fixed, and its attachment distance, wall bracket spacing and end height must comply with the requirements of the 'User Manual'. The angle between the plane of the wall bracket and the normal direction of the attachment surface should not exceed 8 degrees;. When the attachment device does not meet the requirements of the 'User Manual' due to conditions, its calculation sheet,DalasMobile small electric elevator, design and production materials should be confirmed by the manufacturer or reviewed by the technical leader of the installation unit, and verified by experts.

Setting requirements: The up travel (limit) switch should be able to automatically stop the cage running at the rated speed before reaching the upper limit switch, but should not trigger the up travel (limit) switch as high

With the continuous improvement of urbanization level in China, the number of high-rise buildings in urban areas has sharply increased, efforts will inevitably be made to design and produce high-altitude lifting platform vehicles.

Dalas.Monthly maintenance and inspection of hydraulic lifting platform rollers in order to meet the needs of the domestic market and the public, intermediate shafts and bearings, oil cylinder pin shafts and bearings, and at this position, the hydraulic ground should be 40-50 millimeters higher than the bottom of the box. If the hydraulic oil becomes dark, sticky, or has foreign objects such as gravel, it should be replaced in a timely manner (32 # hydraulic oil). Annual maintenance and inspection of all hydraulic pipelines and joints of the lifting platform. The pipeline must not be damaged, and the joints must not be loose. All joints must be tightened. Remove and disassemble the lowering valve of the lifting platform, blow out the plunger with compressed air, then install it and reinstall it. Drain and discard the hydraulic oil, tighten the joint, remove the oil filter, clean it with compressed air, and then return it to the oil tank and connect the pipeline.

The motor of the hydraulic guide rail lifting platform is set around the wellbore, occupying a relatively small area, improving the utilization rate of the wellbore area.

Secondly, for the replacement of hydraulic oil on the lifting platform, it is recommended to replace it every three months. If the frequency of use is not high, it can be replaced once a year. The hydraulic oil must be clean,DalasElectric six meter elevator, and after changing the hydraulic oil, it must be automatically lifted and lowered 2 to 3 times to ensure that the air in the oil cylinder is completely discharged, maintain sufficient space, and ensure that the lifting platform can be lifted to the rated lifting height.