Rotlingen200 kg electric elevatorWhat components are included in the order

announcer:hp935HP175192871 release time:2024-06-09 22:27:26

The landing door should be in a normally closed state. Without the permission of the construction electric elevator driver, the landing door shall not be opened.

The full height landing door should meet the following requirements: the net height of the landing door opening should not be less than 0m. In special circumstances, when the net height of the building entrance is less than 0m, it is allowed to lower the height of the lower door opening, but in any case, the net height of the lower door opening is not less than 8m. (Article 1 of GB26557-2011)

Rotlingen.If the set screw is loose, be sure to pin it tightly to prevent accidents caused by the shaft pin falling off. Hydraulic oil should be kept clean and replaced every 6 months.

The landing door should be in a normally closed state. Without the permission of the construction electric elevator driver, the landing door shall not be opened.

.The scaffolding of the parking platform should be laid tightly and firmly.

To ensure safe and reliable braking of the lifting platform and prevent accidents, a hydraulic control one-way valve, also known as a hydraulic lock,RotlingenElectric banner elevator, and; Program adjustment time delay to avoid frequent movement of electric elevators that may affect their service life.

Every theater is a public place with a large number of people,RotlingenElectric elevator for balcony, and safety considerations should be taken into account in stage design. According to relevant national regulations, in order to prevent accidents caused by the crushing of electric elevators or improper control by drivers. Electric elevators should be equipped with the following necessary safety devices to ensure that the car of the electric elevator stops rising or falling in a timely manner.


Rotlingen200 kg electric elevatorWhat components are included in the order



Mechanical devices controlled by cage movement should not be used to open or close the landing door.

Construction electric elevators should be equipped with emergency stop switches and comply with regulatory requirements.

The safety distance between the outer edge of the upper part of the landing door and the moving parts of the electric elevator during normal operation should not be less than 0.75m; If the rated speed is not greater than 0.7m/s,RotlingenThree wheel electric elevator, the safety distance can be 0.40m.

offer.Vertical lead screw electric lifting mechanism: Adopting a lead screw transmission method, it can achieve the lifting of a double-layer tabletop. Multiple lifting platforms can be formed as needed, and different steps can be formed within the travel range to meet the needs of meetings and performances; Pavilion, Terrace, Tower, Pavilion; Ideal props.

Implementing multiple shifts of homework should fill in and submit records according to regulations.

Construction electric elevators outside the lightning protection range


Rotlingen200 kg electric elevatorWhat components are included in the order



Setting requirements: The installation and dismantling workers, electricians and other operators of construction electric elevators should have special construction operations.

Economic management.When the wall bracket adopts non matching standard products, design calculations should be carried out.

The occurrence of.

Low level doors should be equipped with interlocking devices that can verify their closed and locked positions. The action of this interlocking device should be at the entrance of the cage. Simple use should not interfere with the operation of the interlocking device. The attached wall bracket should use matching standard products. When the wall bracket cannot meet the requirements of the construction site, it should be designed separately. The design of the wall bracket should meet the requirements of component stiffness, strength, stability, etc., and the top floor height can be installed at least 2.5 meters.

Especially suitable for steel structured factories suitable for both indoor and outdoor installation.

Drivers of construction electric elevators should hold special construction operations and are not allowed to operate without a certificate.