SnoreSmall hydraulic electric elevatorProcessing new common problems and corresponding solutions

announcer:hp935HP175192871 release time:2024-06-08 11:17:23

In addition to ground protective fences, low level doors can be used. Low level doors should meet the following requirements: the height of the door should be between 1m and 2m. And there should be at least protective railings, a half height middle crossbar, and a toe board at least 150mm above the ground.

Many theaters use a lifting platform as a vertical transportation tool for goods. The rear of the main stage or the end of the side stage in many theaters are equipped with a set container transportation lifting platform, which is used to vertically transport items from the ground to a designated location or even the stage plane. The lifting platform of the music pool is often used for transporting movable seats, etc.

Snore.The downward movement of the hydraulic cylinder (i.e. heavy object lowering). The hydraulic oil enters the upper end of the hydraulic cylinder through the explosion-proof electromagnetic directional valve, and the return oil from the lower end of the hydraulic cylinder passes through the balance valve, hydraulic control one-way valve, and explosion-proof electric valve

Stage equipment safety door. To prevent personnel from extending their heads,SnoreHand push electric elevator, hands, its cabin should be full of doors, and the height of the hoistway (hall door) should not be less than 8 meters; The electric door opening and closing switches should be removed from the vertical and passenger compartment doors. In order to prevent accidents caused by vertical, passenger car doors, and car roof doors not being closed.; Door interlocks should be installed on both the vertical and passenger compartment doors.

.When the foundation is set on the roof or floor structure, the bearing capacity of its supporting structure should be checked.

Protective measures should comply with regulatory requirements.

During the use period, the user unit should organize professional technical personnel to inspect the construction electric elevator monthly according to the standard requirements, and record the inspection results.


SnoreSmall hydraulic electric elevatorProcessing new common problems and corresponding solutions



The landing door should meet the requirements of the specifications and achieve standardization.

And the decoration team is also using aluminum alloy electric elevators. What safety considerations should we consider during the use process? Many manufacturers have not clearly indicated it. Today, the mechanical editor will talk to you about aluminum alloys

From the above comparison, it can be seen that hydraulic electric lifting mechanisms have stable lifting, low noise, long service life, large load bearing capacity,SnoreElectric elevator mobile type,SnoreMicro electric elevator, and are relatively simple, making them suitable for use in stage equipment.

where.Setting requirements: Before starting work every day and changing shifts, the driver of the construction electric elevator should inspect the construction electric elevator according to the requirements of the user manual and specifications, record the inspection results, and report any problems found to the user unit.

Construction electric elevators should be equipped with cable guide frames and comply with regulatory requirements.

Setting requirements: The guide rail should be rigid and flexible components such as wire ropes or chains should not be used.


SnoreSmall hydraulic electric elevatorProcessing new common problems and corresponding solutions



When a rigid 5000mm2 square or circular flat surface is applied with a normal force of 600N to either side of the door, the door may not meet the above requirements but safety should be maintained.

Quality assurance.Drainage measures need to be considered around the foundation. (Drain the accumulated water on the foundation).

The down travel (limit) switch should be of the automatic reset type.

When the door is closed, except for the gap between the lower part of the door that should not exceed 35mm, any through-hole and opening size related to the distance between any door and adjacent moving parts, as well as the gap around the door or the gap between parts, should comply with the provisions of Table 4 of GB 23821-2009.

Snore.Small safe operation distance: Circuit voltage (kV) of external power lines<11~1035~110220330~550 Small safe operation distance (m) 4681015 Setting requirements: A small safe distance should be maintained between the outer edge of the construction electric elevator and the edge of the external overhead power line.

Many theaters use a lifting platform as a vertical transportation tool for goods. The rear of the main stage or the end of the side stage in many theaters are equipped with a set container transportation lifting platform, which is used to vertically transport items from the ground to a designated location or even the stage plane. The lifting platform of the music pool is often used for transporting movable seats, etc.

Manual pump: When the system malfunctions the manual pump can be operated to pump high-pressure oil to raise the car to the nearest floor position