LexlipGuide rail elevatorHow to reduce the failure

announcer:hp695HP135175170 release time:2024-06-07 19:21:32

Good stability: The overflow valve can prevent excessive system pressure during upward movement. Emergency manual valve: In case of power failure, it can cause the elevator car to descend to the nearest floor position and open the door. Manual pump: When the system malfunctions, the manual pump can be operated to pump high-pressure oil to raise the car to the nearest floor position; Tank oil temperature protection: When the oil temperature in the tank exceeds the standard setting value, the oil temperature protection device sends a signal to suspend the use of the elevator. The elevator can only be started when the oil temperature drops.

Hydraulic oil should be kept clean and replaced every 6 months; When repairing, maintaining, be sure to support the support rod.

Lexlip.The purpose of the hydraulic lifting platform allows users to choose the power mode and configuration according to their own usage range: the power system includes: DC power supply, single-phase or three-phase power supply, diesel engine.

Operating cost advantage: Low failure rate. Due to the use of advanced hydraulic systems and good methods the failure rate of elevator operation can be minimized. Low power consumption: When the hydraulic elevator descends, it is driven by the pressure generated by its own weight, which greatly saves energy.

.The power unit adjustment, whether it is a scissor type lifting platform or a guide rail type lifting cargo elevator is composed of the power unit and the oil cylinder. The power unit has four outlets during production, which can be adjusted to increase or decrease the hydraulic oil flow rate of the oil cylinder. We can adjust the motor speed or the electro-hydraulic proportional valve to adjust the hydraulic oil flow rate; What factors will affect the lifting speed of hydraulic elevators? The longer the hydraulic oil pipe, during installation, the length of the oil pipe should be minimized as much as possible within the allowable range of the design; On the basis of adjusting the power unit, the size of the oil pipeline can also be adjusted, and corresponding adjustments can be made while ensuring that the equipment meets normal demand and safety.

When installing, disassembling, and adjusting the rotating mechanism, it is important to ensure that the centerline of the reducer of the rotating mechanism is parallel to the centerline of the gear, and its meshing surface is not less than 70%. The meshing clearance should be suitable.

Good stability: The overflow valve can prevent excessive system pressure during upward movement. Emergency manual valve: In case of power failure, it can cause the elevator car to descend to the nearest floor position and open the door. Manual pump: When the system malfunctions,LexlipCylinder mounted hydraulic lifting platform, the manual pump can be operated to pump high-pressure oil to raise the car to the nearest floor position; Tank oil temperature protection: When the oil temperature in the tank exceeds the standard setting value, the oil temperature protection device sends a signal to suspend the use of the elevator. The elevator can only be started when the oil temperature drops.


LexlipGuide rail elevatorHow to reduce the failure



The hook of the seat belt should not be hung on unstable or moving objects. High priced and various specifications of scissor lift manufacturers provide timely supply, with high cost-effectiveness, and have become the preferred brand for many wire products. Welcome to purchase!

System: Anti type electronic control system,LexlipHydraulic lifting platform, remote control system, PIC system.

What are the installation precautions for elevators? The folding fence and cage of the elevator should be cleaned of the foundation surface, and the foundation bolts should be installed properly. If the construction elevator is installed on the floor, a pad iron must be used below the screws to increase the force surface between the nuts and the floor to reduce the impact of the nuts on the floor; Insert steel plate shims of different thicknesses between the chassis and the foundation stone at the anchor bolts to adjust the verticality of the guide rail frame; Install three standard sections and measure the verticality of the guide rail frame using a theodolite to ensure the verticality of each main pipe in both directions. After adjusting the verticality of the guide rail frame, tighten the four foundation bolts; Adjust the verticality of the fence door frame as above and tighten the remaining anchor bolts; Install the buffer spring; Connect the other half of the fence to the front half with bolts; Adjust the verticality and tighten the anchor bolts as above and release the brake on the motor inside the suspension cage. (For SC200/200 models, first install the suspension cage before installing the drive plate).

total cost.Motor does not rotate: The motor is broken, and the manufacturer will handle it. We are a long-term manufacturer of scissor type elevators. Welcome to inquire

Pay attention to checking each steel wire rope for broken wires and loose strands. If it exceeds the relevant regulations, it must be replaced immediately. The maintenance and upkeep of steel wire ropes should strictly follow the 85 regulations.

The main structure and purpose of a guide rail elevator: The mechanical part of a guide rail elevator mainly includes three parts: a lifting device, a track device and a belt changing device. The lifting device is mainly used to suspend the person being lifted, which is the core part of the entire mechanism. The track device is mainly used to provide movement trajectory, making operation more smooth. The belt changing device is used to switch tracks when the elevator is about to pass through a door. The internal structure of the lifting device is mainly composed of gear mechanism, bracket, guide mechanism, lifting arm, upper and lower shells, etc. The gear mechanism mainly includes large and small gears,LexlipHydraulic electric lifting platform, winding pulleys, central shafts, and safety devices composed of stop buckles and torsion springs.


LexlipGuide rail elevatorHow to reduce the failure



How to maintain elevators in winter is one reason and the primary reason. Many workers in other industries do not know that hydraulic elevators use different types of hydraulic oil in summer and winter. Often, at low temperatures, the hydraulic oil used in summer can become, or even freeze. After entering low temperatures in winter, it is important to remember to replace hydraulic oil containing antifreeze, which is suitable for working at low temperatures.

demand.The power unit adjustment, whether it is a scissor type lifting platform or a guide rail type lifting cargo elevator, is composed of the power unit and the oil cylinder. The power unit has four outlets during production, which can be adjusted to increase or decrease the hydraulic oil flow rate of the oil cylinder. We can adjust the motor speed or the electro-hydraulic proportional valve to adjust the hydraulic oil flow rate; What factors will affect the lifting speed of hydraulic elevators? The longer the hydraulic oil pipe, the longer the lifting time. Therefore, during installation, the length of the oil pipe should be minimized as much as possible within the allowable range of the design; On the basis of adjusting the power unit, the size of the oil pipeline can also be adjusted, and corresponding adjustments can be made while ensuring that the equipment meets normal demand and safety.

The indicator light is on, press the up button, the motor rotates but the lifting table does not rise. Check≥ Phase power supply, after the power supply is reversed, the motor reverses, but it also has a certain degree of danger. So people invented hydraulic lifting platforms, which are more convenient to help people complete high-altitude operations. However, people should also pay attention when using hydraulic lifting platforms, otherwise they can easily malfunction, which may lead to serious consequences. So what are the common faults of hydraulic lifting platforms?

Lexlip.Pay attention to checking each steel wire rope for broken wires and loose strands. If it exceeds the relevant regulations, it must be replaced immediately. The maintenance and upkeep of steel wire ropes should strictly follow the 85 regulations.

The guide rail type cargo elevator has been inspected and debugged before leaving the factory, and all technical indicators have met the design requirements. When in use, only the power supply needs to be connected, and the hydraulic and electrical systems do not need to be adjusted.

Talking about the daily maintenance and use of hydraulic lifting platform motors. Overloading is strictly prohibited, as overloading can increase the burden on the motor and in severe cases, cause the motor to burn out.