BielefeldExternal wall electric elevatorSize detection

announcer:hp935HP175192871 release time:2024-06-07 16:00:59

During the use period, the user unit should organize professional technical personnel to inspect the construction electric elevator monthly according to the standard requirements,Bielefeld10 meter self-propelled elevator, and record the inspection results.

Stage equipment safety door. To prevent personnel from extending their heads, hands, and feet out of the shaft and objects from falling into the vertical shaft. Its vertical position should be closed, its cabin should be full of doors, and the height of the hoistway (hall door) should not be less than 8 meters; The electric door opening and closing switches should be removed from the vertical and passenger compartment doors. In order to prevent accidents caused by vertical, passenger car doors, and car roof doors not being closed.; Door interlocks should be installed on both the vertical and passenger compartment doors.

Bielefeld.Setting requirements: A limit switch should be set at both the upper and lower ends of the stroke which should be able to cut off the power supply before the suspension cage and other mechanical stop devices (such as buffers), so that the suspension cage can stop

The quality of the standard section should comply with the product manual and specification requirements.

.When the wall bracket cannot meet the requirements of the construction site, it should be designed and calculated separately.

Human improper operation is the main factor causing malfunctions in scissor type electric elevators. When stacking goods, electric elevators should stack the goods neatly, which is better than stacking them in the center of the cargo stacking area of the cargo elevator to avoid imbalance between the two ends of the stacking area. Eventually, during the operation of the electric elevator, it may cause the electric elevator to lose balance. After the goods are stacked completely, ropes should be used to lock the goods, so that they are not afraid of the goods during the lifting process; Careless; Scattered down

After the electric elevator passes the inspection, installation unit and supervision unit to conduct acceptance. For the implementation of construction general contracting, it can cause the car to descend to the nearest floor position and open the door

The movement of its related components is direct.

The safety distance between the outer edge of the upper part of the landing door and the moving parts of the electric elevator during normal operation should not be less than 0.75m; If the rated speed is not greater than 0.7m/s, the safety distance can be 0.40m.

Installation material list.Once again, weekly inspections should be conducted to check whether the connecting screws at various parts of the lifting platform are tightened, whether the sealing rings are damaged or ineffective, whether there is a lack of hydraulic oil, and whether the oil cylinder is leaking. It is necessary to clean the lifting frame, scissors, wiring, and oil cylinder once a week to avoid dust and debris affecting normal operation.

Flat screw mechanical electric lifting mechanism: The lifting platform of this structure has the advantages of small civil engineering coordination, shallow foundation pit required,BielefeldFully self-propelled electric elevator, large stroke, stable operation, low noise, accurate positioning, and low cost. Adopting a horizontal screw drive and a scissor fork structure to achieve the lifting motion of the table, it can be stopped arbitrarily within the range of travel.

The foundation production and acceptance of electric elevators for foundation construction should comply with the user manual and regulatory requirements.


BielefeldExternal wall electric elevatorSize detection



The full height landing door should meet the following requirements: the net height of the landing door opening should not be less than 0m. In special circumstances, when the net height of the building entrance is less than 0m, it is allowed to lower the height of the lower door opening but in any case, the net height of the lower door opening is not less than 8m. (Article 1 of GB26557-2011)

Total quality management.With the continuous improvement of urbanization level in China, the number of high-rise buildings in urban areas has sharply increased, and the height of buildings has also continued to grow. This has created a demand for high-altitude lifting platform vehicles. Therefore, in order to meet the needs of the domestic market and the public, efforts will inevitably be made to design and produce high-altitude lifting platform vehicles.

The isolation and buffering rubber in various parts of the aluminum alloy electric elevator drive device are intact and tightly fitted.

Operating cost advantage and low failure rate: Due to the use of advanced hydraulic systems and good methods, the operating failure rate can be reduced to a low level.

Bielefeld.The bearing capacity of the ground under the concrete foundation plate should be greater than 0.15Mpa.

Double layer steel mesh: The diameter of the steel bars is 12mm, with a spacing of 200mm.

Setting requirements: For construction electric elevators with foundations installed on roof slabs, or other lower suspended structures, the bearing capacity of the foundation support structure should be checked. Click here to download the construction technical information for free. Basic drainage facilities should be installed.