NaplesHydraulic lifting platform frameProduct introduction and installation instructions

announcer:hp530HP141750488 release time:2024-05-09 20:59:11

NaplesHydraulic lifting platform,

The lifting platform is placed on a horizontal support surface, and the concentrated load of MAX load capacity is placed at any position 300mm away from the periphery of the workbench. After lifting 100 times, each load-bearing component must not have deformation or cracks.

Electrical equipment or component failures. Hydraulic elevator manufacturers tell you that the main reasons for high noise generated by electric motors are: bent or severely worn motor rotors, or damaged bearings, which cause electric motors to sweep and produce noise; The cooling fan of the electric motor is damaged or not firmly fixed, resulting in high noise; The electric motor is not firmly fixed and can also cause vibration, producing high noise.

Naples.When repairing the hydraulic system only clean plastic plugs can be used to seal the end of the pipeline.

When encountering signs of overheating in the electric motor, it is necessary to park the car in a timely manner, clean the problem, and continue running. The motor bearings should be smooth and outstanding.

.There are many reasons for unstable workbench descent, such as overload, unstable support, severe eccentric load, hydraulic oil impurities, etc. In response to the above reasons, it can be solved by reducing the load, frequent inspections and maintenance should be carried out, which not only extends the service life of the hydraulic elevator, but also enables it to exert greater power during operation. Of course, hydraulic elevators also have their own regular repair times and protection methods: regular protection (carried out per shift).

Hydraulic lift cargo elevators belong to high-altitude work equipment. Small shaking of the scissor type structure is normal, but excessive deviation is a symptom. It is necessary to find the cause and make correct judgments in a timely manner. Generally speaking, operations above 8 meters are generally allowed. Due to its own weight, devices above this height begin to vibrate in different ranges. The vibration range depends on factors such as weight, lifting height, and intensity of high-altitude operations.


NaplesHydraulic lifting platform frameProduct introduction and installation instructions



For hydraulic cylinders in hydraulic elevators, it is not practical to change their effective working area A (equivalent to displacement) to adjust the speed. Generally, the speed can only be adjusted by changing the flow rate. For variable displacement motors, speed regulation can change both the flow rate and the motor displacement.

If any problems are found, please contact the manufacturer in a timely manner to avoid exceeding the warranty period.

Optional configuration of fixed lifting platform: The fixed lifting platform can be equipped with auxiliary devices according to usage requirements, and can be combined in any combination, such as the safety protection device of the fixed lifting platform; Electrical methods; Form of work platform; Power form etc. The correct selection of various configurations maximizes the functionality of the lifting platform and achieves effective use.

Meticulous workmanship.I believe many people want to know about the maintenance issues of guide rail hydraulic lifting platforms,NaplesHydraulic lifting platform, as it is related to their service life. During use, frequently check the connection of each part. If loose, tighten it. When the body is under pressure, the tightness of the connecting bolts of the body should be checked (the pressure state that can be used). All connecting shafts should have split pins and hydraulic cargo elevators should be fully opened.

This paper briefly introduces some matters that should be paid attention to in the selection of oil tank for hydraulic elevators. The main functions of the hydraulic oil tank for elevators in the hydraulic systems of hydraulic machinery such as elevators and hydraulic elevators are oil storage, heat dissipation,NaplesHydraulic lifting table lifting, if the wind force exceeds level 5, please stop using it; When the lifting height exceeds 10 meters, the wind ropes at the four corners of the hydraulic lift platform should be tightened and fixed, and the support legs should be reinforced for protection and stability to avoid safety accidents caused by excessive swinging of the electric lifting platform


NaplesHydraulic lifting platform frameProduct introduction and installation instructions



Stable and widely applicable cargo lifting equipment is mainly used for transporting goods between height differences in production lines; Material online and offline; Adjust the height of the workpiece during assembly; High altitude feeder feeding; Lifting of components during assembly of large equipment; Large machine material and cutting; The warehouse loading and unloading site is equipped with forklift and other transportation vehicles for rapid loading and unloading of goods.

Industry management.The hydraulic lifting platform is a manually movable type, and the lifting power of the platform is a two machine or three-phase power supply. It has manual and electric power, and is also equipped with a hand pump for use in case of power outage. This series of platforms have the characteristics of flexible movement, stable lifting, and easy operation, and are mainly used in factories, government agencies, commercial stores, and the construction and decoration industry.

Cylinder diameter and hydraulic oil flow rate. The speed of the hydraulic lifting device is inversely proportional to the cross-sectional area of the cylinder rod and directly proportional to the flow rate of hydraulic oil. When the hydraulic elevator runs slowly priority should be given to the hydraulic oil flow angle.

The main device does not engage. When this fault occurs, check whether the three-phase power supply is normal, whether the internal and external emergency stop button switches, whether the three-phase electrical phase sequence is correct, and whether the relay working indicator light is on.

Naples.Lifting mechanism: The workbench should be ensured to rise and fall smoothly, and there should be no jumping lifting phenomenon. All moving parts should be flexible when moving, and there should be no jamming devices. The lifting system of the elevator is divided into electric or manual hydraulic systems, and there should be no leakage at all components, pipelines, and joints.

Regularly check whether each organization is functioning properly and whether there is noise. If problems are found, they should be promptly cleaned up.

After 5000 hours of elevator operation carry out medium maintenance on the mechanical and electrical systems.