GorinchemElevating cargo elevators from first to second floorsPerformance and precautions when using

announcer:hp779HP136589660 release time:2024-05-05 14:52:24

Is the water cooling and air cooling of the hydraulic station the same?

Regardless of whether it is used outdoors or indoors, it is inevitable that some small problems will occur after a long period of time. At this time, what we should do is to maintain and maintain the elevator. How to follow the steps correctly becomes a difficult problem. Let me explain it to you.

Gorinchem.Manual hydraulic lifting platform application Manual hydraulic platform performance: The manual hydraulic platform truck is made of high-strength steel, with a reasonable and compact design structure, safety, stability, and reliability. It is equipped with a safety valve, a fully sealed oil cylinder, and a manual hydraulic system for lifting and lowering, making it easy to operate. Equipped with a guide wheel to save the operator's physical strength, and can protect the load wheel and pallet load wheel. Unique hydraulic pump design, the pump is simple and designed to maintain an ideal height for pipeline loading and unloading operations; The unique design concept makes the operator's operation simple and convenient.

Secondly, there should be no dirt on the friction surface. If there is any dirt, it should be washed off with gasoline or thinner; The reduction gearbox, gearbox, external meshing gear, and other parts of the equipment, as well as the hydraulic oil, must be tested according to the requirements in the table; Correct maintenance of the hydraulic guide rail elevator: Regularly inspect the wire ropes at various parts for broken wires and looseness. If any such phenomenon is found, replace it in a timely manner. The maintenance of the wire ropes must be carried out in strict accordance with the specifications; Check the connection condition of each part according to the braking rules and regulations. If there is any looseness, tighten it in a timely manner. Check the tightness of the connecting bolts of the equipment when the body is under pressure. All connecting shafts should be equipped with cotter pins; Check whether the operation of each mechanism is normal, whether there are noises and faults according to regulations, disassembling, and adjusting the rotating mechanism of the equipment, and if there is overheating of the motor. Replace the motor in a timely manner and eliminate the fault before continuing operation; Ensure that the bearings and the meshing clearance should be appropriate; Regularly conduct a comprehensive inspection of the equipment to see if there is any damage to the wires and cables, boxes distribution boxes, and that the travel switch points of each safety device must be safe and reliable.

.Precautions for elevator installation: Keep the access road of external construction elevators smooth and have sufficient space for parking equipment. When using a steam crane for auxiliary installation,GorinchemWarehouse elevator, full consideration should be given to whether the on-site environment meets the operating conditions of the steam crane.

Incorrect connection of the elevator motor When a coil, coil group,GorinchemElevating cargo elevator 1-4 floors, or one phase winding group is connected inversely, it can cause a serious imbalance in the three-phase current and cause the winding to overheat.

Walking: assisted self-propelled, two wheel traction, self driving, and car modification.


GorinchemElevating cargo elevators from first to second floorsPerformance and precautions when using



Usage: Scissor fork type fixed lifting platforms are mostly used for goods transportation between height differences in production lines, loading and unloading materials, adjusting the working height during workpiece assembly feeding materials to loading machines at high altitudes, lifting components during assembly of large equipment, matching storage and loading sites with forklift trucks and other transportation vehicles for rapid loading and unloading of goods, vehicle lifting, fixed three-dimensional parking, and other places.

How to install and use the bearings of the elevator During the process of installing the bearing device of the elevator, we cannot always ensure that the bearing device has the correct orientation, which inevitably leads to some devices not in place or bearing misalignment. Once these problems occur in the device, the clearance between the bearings becomes too small, and then the inner and outer rings of the bearings cannot be located at the same rotation center. Therefore, when installing bearings, it is necessary to use specialized tools, and in the future, it is also necessary to use a detector to test the bearing device, so as to ensure the success of the bearing device.

In addition, it is strictly prohibited to use a hammer during installation to prevent excessive axial or radial force from damaging the bearings or gears. Be sure to tighten the mounting bolts before tightening the tension bolts. Before installation, clean the anti rust oil on the motor input shaft, positioning boss, and elevator connection parts with gasoline or zinc sodium water. Its purpose is to ensure the tightness of the connection and the flexibility of operation, and to prevent unnecessary wear and tear.

offer.It is strictly prohibited for personnel to climb up and down the floors by using the goods elevator privately.

Motor connection error. When the triangular connection motor is mistakenly connected into a star shape, the motor still operates with full load, and the current flowing through the stator winding exceeds the rated current, leading to the motor stopping itself. If the stopping time is slightly longer and the power supply is not cut off, the winding will not only be severely overheated, but also burned. When a star connected motor is mistakenly connected into a triangle, or when several coil groups are connected in series into a single branch, the motor is mistakenly connected into two branches in parallel, both the windings and the iron core will overheat, and in severe cases,GorinchemGuide rail chain lifting cargo elevator, the windings will be burned.

The cleanliness of the hydraulic station is an important aspect of the elevator hydraulic station, so it should not be taken lightly. Moreover, from a professional perspective, there are relevant rules and requirements. You should refer to the specification manual, so that you can have a correct understanding and know how to achieve better cleanliness.


GorinchemElevating cargo elevators from first to second floorsPerformance and precautions when using



Frequently check for water accumulation and humidity. It is inevitable for aerial vehicles to drive in rainy and snowy weather, or muddy roads. The bottom and some gaps and indoor floors are prone to sludge accumulation. If the owner does not clean them in a timely manner, this can cause moisture to hide. Therefore, activities in the outer edges of wheel hubs, doors, bottom corners of tree trunks, key holes, and wiper brackets, as well as other areas, should be regularly inspected, and the drainage holes in the doors and various parts should be kept unblocked to ensure that the car seat covers, such as humidity, carpets, and floors, prevent rust from forming parts.

production.Systems: explosion-proof electronic control system, remote control system, PIC system.

Main structure and purpose of guide rail type elevator: The mechanical part of guide rail type elevator mainly includes three parts: lifting device, track device, and belt changing device. The lifting device is mainly used to suspend the lifted person, which is the core part of the entire mechanism. The role of track device is mainly to provide movement trajectory, making operation more smooth. The belt changing device is used to switch tracks when the elevator is about to pass through the door. The internal structure of the lifting device is mainly composed of a gear mechanism, a bracket, a worm gear, a lifting arm, upper and lower shells, etc. Gear mechanism Gear mechanism mainly includes large and small gears, winding pulley, central shaft, and safety device composed of stop buckle and torsion spring.

Walking: assisted self-propelled, self driving and car modification.

Gorinchem.To ensure excellent power supply at the installation site, install a separate distribution box. When using the distribution box the electrical leakage switch must meet the requirements for construction elevators. If the installed construction elevator is variable frequency, the selection of the leakage switch should be compatible with the frequency converter.

Precautions for using guide rail type elevators: Overloading and transporting flammable and explosive products are strictly prohibited.

The elevator is a kind of elevator equipment composed of a walking mechanism, a hydraulic mechanism an electric mechanism, and a support mechanism. The hydraulic oil forms a certain pressure by a vane pump, flameproof electromagnetic directional valve, throttle valve, hydraulic control one-way valve, and balance valve. This allows the hydraulic cylinder to move upward and lift heavy objects. The return oil from the upper end of the hydraulic cylinder returns to the tank through the flameproof electromagnetic directional valve, and its rated pressure overflow valve is adjusted. Observe the reading value of the pressure gauge on the pressure gauge.